17 Style Multifuctional Firemen Protective Suits with OEM Service

China 17 Style Multifuctional Firemen Protective Suits with OEM Service, Find details and Price about China Fireproof Suit, Fire Protection Suit from 17 Style Multifuctional Firemen Protective Suits with OEM Service

Model NO.
ZFMH-HC S(DRD)
Trademark
HCXF
Specification
Top and pants
Origin
Jiujiang
Model NO.
ZFMH-HC S(DRD)
Trademark
HCXF
Specification
Top and pants
Origin
Jiujiang
17 Style Multifuctional Firemen Protective Suits with OEM Service

Product introduction
The protective clothing adopts three layers, namely, the outer layer (Bangwei Putai Double Silk II), the waterproof and breathable layer (heat insulation layer) (aramid non-woven fabric+flame retardant PTFE film) and the comfort layer (Bangwei Putai aramid viscose flame retardant cloth). Protective clothing has the advantages of flame retardance, portability, strong tensile strength, anti-static and eye-catching logo, which can protect firefighters from fighting for a long time. A hidden life-saving drag belt (DRD) is arranged under the back collar of protective clothing, so that when rescuers are injured or fall to the ground, other team members can quickly drag them away from the dangerous scene.

Material and structure
1. Main structure
- The upper and lower split structure, the overlapping part between jacket and trousers is ≥200mm.
- Collar: The collar is designed as a stand collar, with a protective collar at the front collar and a comfortable fabric with smooth color on the inside of the collar.
- Reflective marker band: one 360-degree annular marker band is set on the chest, hem and cuffs of the jacket, and one 360-degree annular marker band is set on the legs of the trousers. The width of reflective marking tape is 50.8mm(2 inches), and the color is yellow, silver and yellow.
- Pants crotch: pants crotch adopts integrated design.
-Pant strap: equipped with H-shaped strap, the length of which can be adjusted as required and can be disassembled.
- The front front zip of the jacket is No.8.

2. Additional structure
- Pocket: A radio stereo pocket is arranged outside the left chest of the jacket, with an internal pocket and an external patch pocket at the hem. One tool bag is set on the lateral thigh. All outer pockets are provided with water leakage holes.
- Hook and loop of left arm: there is a 90mm×110mm shield-type hook and loop on the outer side of left upper arm, which can be pasted with shield-type logo.
- Cuff: The cuff is designed with horseshoe cuffs, the outer layer is covered with material, the tightening adjustment loops are set, and the ribbed protective wristband is equipped with thumb holes, and the inside is provided with water-stopping cloth.
- Coat placket: the hook and loop of coat placket is through design.
- Coat hem: the hem of the comfortable layer of the coat is provided with water-stopping cloth.
- Trousers leg opening: the trousers leg opening adopts circular arc design, with water-stop cloth inside, zipper inside, and wear-resistant material wrapping around the trousers leg.
- Reinforcement treatment: shoulder, elbow and knee are thickened with wear-resistant layer, which is soft and easy to clean.
- Two hanging loops are arranged on the left shoulder and the right shoulder.

Size dimension
Size165A165B170A170B175A175B180A180B185A185B190A190B
Tall163-167168-172173-177178-182183-187188-192
Chest8892-9692-9610092-96100100104-108100104-108104-108112


Application
Firefighters' protective clothing is mainly special clothing worn by firefighters during fire fighting and rescue, which is used to protect the trunk, head and neck, arms and legs. This product cannot be used in high temperature environment (such as jungle fire, wilderness fire and forest fire).

Safety use
1. Please read the instruction manual carefully before using protective clothing.
2. Fire fighting and rescue operations are highly dangerous, and personnel without professional training are prohibited from using protective clothing to enter the fire area without authorization.
3. Before using protective clothing, you must carefully check whether there are cracks and wear marks on the surface of the clothing. If you find any damage, you should immediately stop using it and replace it with intact protective clothing.
4. The user should choose protective clothing of appropriate size. When wearing it, the jacket and trousers must be used together. At the same time, all parts of the fire-fighting protective clothing, such as buckles, buttons, zippers and collars, must be fastened. It should be used in conjunction with firemen's personal protective equipment such as helmets, hoods, gloves, boots, etc., so as to protect firemen's body more comprehensively.

Kindly Noted
1. Try to avoid direct contact between protective clothing and flame, molten metal and sharp objects.
2. It is forbidden to use protective clothing in high temperature, chemical, radiation and electric fields.
3. If the original structure of protective clothing has been damaged due to wear, tear or chemical erosion, it should be discarded. Unless the company's special fabrics and special high-temperature resistant sewing threads are used for repair, it is strictly forbidden to use other fabrics that have not been tested for fire resistance without authorization, so as not to affect the overall flame retardant performance of the clothing and may cause accidents during operation.

 
Maintenance
1. Firefighters should regularly check the protective clothing they wear, and clean it in time when there are stains. Wash with water or professional washing machine to avoid dry cleaning. The water temperature should be 35-48ºC, and neutral detergent should be added to avoid bleach and softener.
2. If the protective clothing is contaminated with serious stains such as oil stain and blood stain, it should be smeared with multiple amounts of detergent in advance, rubbed by hand or lightly brushed with a brush and rinsed with clear water before washing. Please disinfect with disinfectant after removing blood stains.
3.Avoid exposure to sunlight or fluorescent lamps for a long time when the protective clothing is dried to prevent ultraviolet rays from damaging the protective performance. If drying is adopted, the temperature during drying should not exceed 60ºC, so as to prevent the micropores in the breathable layer from blocking and affecting the breathable effect of clothing.
4. Protective clothing should be stored in a dry and ventilated warehouse. In addition, it must be washed and dried before storage to ensure that this garment is clean and tidy before storage.
5. When the protective clothing needs to be stored in a whole case, the cartons should be placed on wooden boards or shelves to prevent the clothing from getting damp. If it is stored for a long time, it should be taken out and dried regularly to prevent clothes from getting damp, mildew, insects and bacteria.
6. Avoid mixing protective clothing with inflammable and explosive articles or chemicals such as oil, acid and alkali during transportation.