China WiFi Control Heat Pump Heater Air Source Swimming Pool Heat Pump, Find details about China Heat Pump, Pool Heat Pump from WiFi Control Heat Pump Heater Air Source Swimming Pool Heat Pump
FULL INVERTER SWIMMING POOL HEAT PUMP FIQ SERIES
LASWIM full inverter swimming pool heat pump FIQ series is specially designed for silent and comfortable user experience, with COP up to 15 while sound level is down to 42dB. Thanks to the DC inverter compressor, stepless inverter control system and brushless fan motor, the speed can be adjusted Hz and round by round, to achieve energy saving and super silence.
Technical parameters
Model | LAS07-KP-FIQ | LAS09-KP-FIQ | LAS13-KP-FIQ | LAS16-KP-FIQ | LAS20-KP-FIQ | LAS24-KP-FIQ |
Performance condition: Air 27ºC/ Water 27ºC/ Humid.80% | ||||||
Heating capacity(kw) | 6.8 | 9 | 12.6 | 16.1 | 20 | 24 |
COP Range | 13.5-6.3 | 14.0-6.5 | 14.0-6.4 | 15.0-6.5 | 15.0-6.5 | 14.5-6.4 |
Average COP at 50% Speed | 9.2 | 9 | 9.5 | 9.6 | 9.3 | 9.6 |
Performance condition: Air 15ºC/ Water 26ºC/ Humid.70% | ||||||
Heating capacity(kw) | 5 | 6.5 | 9 | 11 | 14 | 16.2 |
COP Range | 6.8-4.3 | 6.8-4.5 | 7.0-4.4 | 7.0-4.5 | 7.0-4.6 | 7.2-4.5 |
Average COP at 60% Speed | 6.1 | 6.2 | 6.3 | 6.3 | 6.2 | 6.3 |
Technical specifications | ||||||
Advised pool volume(m³) | 15-30 | 20-50 | 30-60 | 40-75 | 50-90 | 60-110 |
Operating air temperature(ºC) | -5ºC~43ºC | |||||
Compressor | Twin-rotary Mitsubishi DC Compressor | |||||
Heal exchanger | Twisted Titanium Heat Exchanger | |||||
Power supply | 220-240V /1Ph/ 50-60Hz | |||||
Refrigerant | R32 | |||||
Material | ABS+Aluminum-alloy Casing | |||||
Rated input power(kw) | 0.18-1.17 | 0.24-1.45 | 0.32-2.10 | 0.39-2.50 | 0.5-3.10 | 0.56-3.70 |
Input power at 50% Speed(kw) | 0.41 | 0.53 | 0.72 | 0.88 | 1.13 | 1.29 |
Rated input current(A) | 0.79-5.10 | 1.05-6.40 | 1.40-9.00 | 1.70-10.70 | 2.18-13.3 | 2.45-16.1 |
Maximum Input current(A) | 7.5 | 8.5 | 10.5 | 15.5 | 18 | 20 |
breaker rated current(A) | 9 | 10 | 13 | 18 | 21 | 24 |
Power cord(mm²) | 3*1.5 | 3*1.5 | 3*2.5 | 3*2.5 | 3*4 | 3*6 |
Sound level at 1m dB(A) | 38.5-48.0 | 39-48.4 | 42.2-50.8 | 41.2-54.4 | 43.4-54.1 | 41.6-56.0 |
Sound level by 50% speed 1m dB(A) | 41.2 | 41.6 | 45.8 | 45.9 | 46.8 | 47.3 |
Sound level at 10m dB(A) | 18.5-28.0 | 19.0-28.4 | 22.2-30.8 | 21.2-34.4 | 23.4-34.1 | 21.8-36.0 |
Advised water flux(m³/h) | 2-4 | 2-4 | 4-6 | 6-8 | 7-10 | 10-12 |
Water connection(mm) | 50 | |||||
R32 Net weight(g) | 500 | 550 | 750 | 800 | 1000 | 1200 |
Net weight/Gross Weight(kg) | 56/67 | 58/67 | 61/70 | 64/72 | 70/80 | 80/90 |
Net dimension L*W*H(mm) | 890*430*657 | 890*430*657 | 890*430*657 | 890*430*657 | 1060*430*657 | 1060*430*757 |
Qty per 20'FT/40'HQ(sets) | 78/177 | 78/177 | 78/177 | 78/177 | 72/150 | 48/150 |
Remarks:
The above data will be subject to change without further notice, please refer to the nameplate on the unit.
Advised pool volume applies to a private pool with an isothermal cover, from April to September.
1.Super silence
*Unique backward airflow helps to provide comfort silence swimming experience, It adopts invisible fan to draw air from two sides and exhaust out from back side to eliminate every possible noise to realize silence and comfort, and achieve a sound level down to 42dB(A) at 1m, 10dB(A) lower than On/Off heat pump.