Air Source Domestic Hot Water Cold Water Chiller Heat Pump

China Air Source Domestic Hot Water Cold Water Chiller Heat Pump, Find details about China Heat Pump, Air Source Heatpump from Air Source Domestic Hot Water Cold Water Chiller Heat Pump

Model NO.
LAS-KP-DI
Origin
China
Model NO.
LAS-KP-DI
Origin
China
DC INVERTER SWIMMING POOL HEAT PUMP
Inverter technology makes swimming pool heat pump achieve an extremely high COP and quiet operation. With variable running speed basing on actual heating or cooling requirements, it warms up the pools at a low speed when the pool temperature is getting close to the set temperature. LASWIM DC inverter swimming pool heat pump helps to cut the running cost and provides a comfortable swimming environment.

1.COP up to 11
*(Air 27ºC/Water 27ºC/Humidity 80%)
*No matter it's cold or warm, it will adjust the heating capacity according to the pool water temperature. When running at 20%-25% speed, it reaches the highest COP 11.

2.Super energy saving
*With low-speed running, DC inverter heat pump is double energy saving than traditional on/off heat pump.

3.Silent operation
*Thanks to the stable DC inverter control system, DC inverter compressor and variable speed ventilator, LASWIM DC inverter heat pump runs very silently and provides you a comfortable swimming environment.

4.Smart WIFI control(Optional)
*With smart APP control, you can check and control your heat pump anytime and anywhere, all information is at your fingertips.

Other features
1.EEV technology
 10 times flexibility to adjust the gas flow and increase the COP up to 2% higher.


2.ECO-Friendly refrigerant
 32% GWP comparing to R410A, 25% CO2 carbon consumption and 25% quota cost


3.Wide voltage
 Self-adjustment to fit in unstable power supply, therefore voltage range can be 180~260V.

4.Twisted titanium heat exchanger
 40% higher efficiency than normal titanium heat exchanger.

5.Reverse cycle defrosting
 With Saginomiya 4-way valve for quick and efficient defrosting.

6.Soft starter
Start from 0 Amps to rated Amps steadily, No rush to house electricity system.

7.0ºC~43ºC
Designed for down to Air 0ºC operation.

8.ABS casing

Anti-UV and anti-corrosion

Air Source Domestic Hot Water Cold Water Chiller Heat PumpAir Source Domestic Hot Water Cold Water Chiller Heat PumpAir Source Domestic Hot Water Cold Water Chiller Heat Pump


Technical Parameters:
 
ModelLAS07-KP-DILAS09-KP-DILAS13-KP-DILAS16-KP-DILAS20-KP-DILAS24-KP-DI
Performance   condition: Air: 27ºC / Water:   27ºC / Humidity: 80%
Heating capacity (kW)79131620.224.2
COP Range10.1~610.4~6.210.8~6.310.6~6.210.8~6.110.8~6.2
Average COP at 50%   speed8.99.19.29.19.19.2
Performance   condition:: Air: 15ºC / Water:   26ºC / Humidity: 70%
Heating capacity (kW)56.49.111.11416.2
COP Range6.2~4.36.5~4.26.2~4.56.6~4.36.5~4.26.6~4.5
Average COP at 50%   speed5.96.166.16.16.2
Technical   specifications
Advised pool   volume (m³)15-3020-4535-6540-7550-9060-110
Operating air   temperature (ºC)0ºC~43ºC
CasingABS material
Heat exhangerTwisted titanium heat  exchanger
Refrigerant typeR32
Power supply230V/1N/ 50Hz
Rated  input power (kW)0.24~1.180.28~1.560.41~2.020.50~2.550.60~3.250.72~3.82
Input power at 50%   speed (kW)0.420.540.750.91.151.3
Rated  input current (A)1.0~5.061.21~6.731.76~8.72.17~11.122.61~14.163.13~16.56
Maximum input   current (A)6.5812.51719.520.5
Power cord (mm²)3X1.53X1.53X2.53X43X63X6
Sound level at 1m40~51.241.6~53.544~54.046.2~57.446.3~58.246.9~58.8
Sound level  by 50% speed at 1m dB(A)43.846.849.549.850.651.2
Sound level at 10m   dB(A)19.8~31.221.6~33.623.9~34.226.2~37.326.3~38.227~38.8
Advised water flow   (m³/h)2~43~54~66~87~1010~12
Water connection   (mm)50
R32 Net weight   (g)400550900100011001300
Gross weight   (Kg) 475255677678
Net weight   (Kg) 434749606868
Net dimension LxWxH (mm)903*349*654903*349*654903*349*654991*349*654991*349*754991*420*757
Loading quantity   of 20ft/40HQ (Sets)102/216102/216102/21690/19860/19850/162

Remarks:
* The data above is only for reference, for specific data, please refer to the nameplate on the unit.
* Advised pool volume applies to a private with isothermal cover, from April to September.