XRY -1C Automatical Oxygen Bomb Calorimeter

China XRY-1C Automatical Oxygen Bomb Calorimeter, Find details about China Oxygen Bomb Calorimeter, Calorimeter from XRY-1C Automatical Oxygen Bomb Calorimeter

Model NO.
XRY-1C
Trademark
Shangyi
Transport Package
by Wooden Case
Specification
540mm*420mm*420mm, 55kgs
Origin
China
HS Code
9027809900
Model NO.
XRY-1C
Trademark
Shangyi
Transport Package
by Wooden Case
Specification
540mm*420mm*420mm, 55kgs
Origin
China
HS Code
9027809900

XRY-1C Oxygen Bomb Calorimeter

Summary

  The instrument is designed and made as per the National Standard of People's Republic of China GB/T213-2008 and ASTM D240 Test Method for Calorific Value of coal, GB/T384-1988 Test Method for Calorific Value of Petroleum Products and Calibration Regulation of People's Republic of China JJG672-2001 Oxygen Bomb Calorimeter, as well as Shanghai enterprise standard Q/YXYY 10 XRY Series Oxygen Bomb Calorimeter.

I. Main technical features

1. Adopting semiconductor refrigeration to decide the refrigerating capacity according to the calorific value,the instrument can automatically adjust water temperature and keep water in a relative constant temperature range,realize the continuously and long time test requirement,and make sure the test result is correct.

2. Using USB port,convenient to connect.One computer can control many sets of Oxygen Bomb Calorimeter.

3. With a electronic measuring cup itself,no need to weigh the water by manual,it can measure the water volume automatically,the repetitive error<0.4g

4. Automatically detecting the resistance of ignition filament,automatically checking the installing condition of ignition filament before test.

5. Standard pipeline design,vastly shortening the pipeline,and more reasonable pipeline design to ensure more precision of test results.

6. Adopting professional discharge water ports,more convenient and fast when the  instrument drains away water or change the water.

7. The electronic balance with communication function to share the data by the internet.

II. Main technical specifications

1. Measuring temperature range: 5ºC~40ºC

2. Temperature resolution: 0.0001ºC

3. RSD(Relative standard deviation): ≤0.1%

4. Test period: ≤13mins

5. Measuring range: 5MJ/kg~40MJ/kg

6. Accuracy:Better than GB/T213-2008 The determination method of coal calorific value

7. Pressure endurance of oxygen bomb: 20 MPa

8. Relative humidity: ≤85%

9. Power supply: AC 220V±10V, 50 Hz

10. Total power consumption: ≤0.2kW

11. Outline dimension: 540mm×420mm×420mm(L×W×H)

12. Net weight: 55kg

III,XRY-1C Oxygen Bomb Calorimeter Accessories and Documents List
NoNameUnitQtyRemark
1Main unit of calorimeter (includes oxygen bomb, water jacket, water bucket, stirrer)Set1 
2ComputerSet1 
3PrinterSet1 
4Holder of bomb headSet1 
5Holder of oxygen bombSet1 
6Temperature sensorPiece1 
7Thermometer (0~50 ºC)Piece1 
8Stopper for thermometer (silica gel stopper 2 #)Piece1 
9Ignition wire (Φ0.12 Ni-Cr wire)Meter10 
10Crucible Piece2 
11Discharging valve Piece1 
12Oxygen decompression devicePiece1 
13Oxygen pipePair1 
14"O" seal ring (Φ20 ×2.4)Piece5 
15"O" seal ring (Φ8×1.9)Piece5 
16"O" seal ring (Φ6×1.9)Piece5 
17"O" seal ring (big O ring)Piece2 
18Ignition connection wirePiece1 
19Power supply wire (250 V 6 A)Piece1 
20Serial port wire Piece1 
21Benzoic acidPiece10 
22Stopping ring for thermometer (1#)Piece4 
23Fuse 2 A (Φ5×20)Piece2 
24Silica gel stopper (7#)Piece1 
25SiphonPiece1 
26Operation Manual  Piece1 
27Quality CertificatePiece1 
28Repair Guarantee Piece1 
29Operating software CDPiece1