Charge for The Battery Inverter Inverter with Solar Contoller Sgt-80kw

China Charge for The Battery Inverter Inverter with Solar Contoller Sgt-80kw, Find details about China Power Inverter, 80kw 384V Inverter from Charge for The Battery Inverter Inverter with Solar Contoller Sgt-80kw

Model NO.
SGT-80KW
Nature of Wave String
Sine Wave Inverter
Type
DC/AC Inverters
Dimension
87.5*72*138cm
N.W./Unit(Kg)
512kg
Meas
98*82.5*156cm
G.W./CTN(Kg)
552kg
Trademark
SUG
Transport Package
Carton
Specification
SGT-80KW
Origin
China
HS Code
8504403090
Model NO.
SGT-80KW
Nature of Wave String
Sine Wave Inverter
Type
DC/AC Inverters
Dimension
87.5*72*138cm
N.W./Unit(Kg)
512kg
Meas
98*82.5*156cm
G.W./CTN(Kg)
552kg
Trademark
SUG
Transport Package
Carton
Specification
SGT-80KW
Origin
China
HS Code
8504403090
Charge for The Battery Inverter Inverter with Solar Contoller SGT-80KW
Charge for The Battery Inverter Inverter with Solar Contoller Sgt-80kwCharge for The Battery Inverter Inverter with Solar Contoller Sgt-80kwCharge for The Battery Inverter Inverter with Solar Contoller Sgt-80kwCharge for The Battery Inverter Inverter with Solar Contoller Sgt-80kwCharge for The Battery Inverter Inverter with Solar Contoller Sgt-80kwCharge for The Battery Inverter Inverter with Solar Contoller Sgt-80kw
Charge for The Battery Inverter Inverter with Solar Contoller Sgt-80kwCharge for The Battery Inverter Inverter with Solar Contoller Sgt-80kw
Product Parameters
          
Specification
Model: SGT4KVA6KVA7KVA8KVA10KVA15KVA20KVA25KVA
Rated Power3.2KW4.8KW5.6KW6.4KW8KW12KW16KW20KW
Battery Voltage48/96/192VDC96/192/384VDC
Specification
Model: SGT30KVA40KVA50KVA60KVA80KVA100KVA125KVA150KVA
Rated Power24KW32KW40KW48KW64KW80KW100KW120KW
Battery Voltage192/384VDC384VDC
Parameter
InputAC Input Voltage Range380Vac/400Vac±10%(customized 190Vac/200Vac)
AC Input Frequency Range45Hz-65Hz
Phase3/N/PE
OutputEfficiency≥85%
Output Voltage(Battery Mode)380Vac/400Vac±10%(customized 190Vac/200Vac)
Output Frequency(Battery Mode)50/60Hz ±1%
Output Wave(Battery Mode)Pure Sine wave
THDliner load≤3%
AC Output Voltage RangeConforming to AC input
AC Output Frequency RangeConforming to AC input
Phase3/N/PE
Inside Solar
Controller
(optional)
Charging ModeMPPT or PWM
Charging Current12V/24V/48V System:10A,20A,30A,40A,50A,60A; 96V/192V/384V System:50A,100A,150A,200A
PV Input Voltage Range12V System:15V-44V;24V System:30V-44V;48V System:60V-88V;
96V System:120V-176V;192V System:240V-352V;384V System:480V-704V
Max PV Input Voltage
(At 25°C)
12V/24V System:50V;48V System:100V;96V System:200V;192V System:400V;384V System:750V
PV Array Maximum Power12V System:140W,280W,420W,560W,700W,840W;24V System:280W,360W,840W,1120W,1400W,1680W;
48V System:560W,1120W,1680W,1120W,2240W,3360W;96V System:5.6KW,11.2KW,8.4KW*2,11.2KW*2
192V System:11.2KW,22.4KW,16.8KW*2,22.4KW*2;384V System:22.4KW,44.8KW,33.6KW*2,44.8KW*2
BatteryDC input voltage range10.5-17V DC/Single battery
Battery low voltage alarm11V/Single battery
Battery low voltage protection10.5V DC/Single battery
Battery high voltage alarm15V/Single battery
Battery high voltage protection17VDC/Single battery
Battery TypeU0: Gel U.S.A / U1: A.G.M.1  /U2:  A.G.M.2 / U3: Sealed lead Acid / U4: Gel European /
 U5: Open lead Acid / U6: Calcuim(open) / U7: Sulphation cycle
Working ModeBattery First/AC First/Saving Energy Mode
AC Charging current(selectable)0~45A
Transfer Time≤4ms
DisplayLCD
Thermal methodForced air cooling
ProtectionOver-load / Over-discharge / Short circuit / High and low temperayure
CommunicationRS232/RS485/APP/SNMP/GSM (Optional)
EnvironmentTemperature -10ºC~40ºC
Height2000m(Less load when height over)
Noise≤65dB
Humidity0%~95%(No condense)
Note:All specifications are subject to charge without prior notice