China S2100e Constant Pressure Water Supply AC Drive, Find details about China Frequency Inverter, AC Drive from S2100e Constant Pressure Water Supply AC Drive
Items | S2100 E | ||
Power Supply | Rated voltage, Frequency | Single phase/Three phase 220V 50/60Hz Single-phase 220V 50/60Hz | |
Voltage Range | 380V:330V~440V; 220V:170V~240V | ||
Output | Voltage Range | 380V:0~380V; 220V:0~220V | |
Frequency Range | 0.10`400.00Hz | ||
Control method | V/F control, Space vector control. | ||
Indication | Operating status/Alarm definition/interactive guidance: eg, frequency setting, the output frequency/current, DC bus voltage, the temperature and so on. | ||
Control Specifications | Output Frequency Range | 0.10Hz~400.00Hz | |
Frequency Setting Resolution | Digital input:0.01Hz, analog input:0.1% of maximum output frequency | ||
Output Frequency Accuracy | 0.01Hz | ||
V/F Control | Setting V/F curve to satisfy various load requirements | ||
Torque Control | Auto increase: auto raise torque by loading condition; manual increase; enable to set0.0~20.0% of raising torque | ||
Multifunctional Input Terminal | Eight multi-function input terminals, realizing functions including fifteen section speed control, program running, four-section acceleration/deceleration speed switch, UP/DOWN function and emergency stop and other functions | ||
Multifunctional Output Terminal | 3 multi-function output terminals for displaying of running, zero speed, counter, external abnormity, program operation and other information and warnings | ||
Acceleration/deceleration time Setting | 0~-6000s acceleration/deceleration time can be set individually | ||
Other Functions | PID Control | Built-in PID control | |
RS485 | Standard RS485 communication function(MODBUS) | ||
Frequency Setting | Analog input:0 to 10V,,0 to 20mA can be selected;z Digital input: Input using the setting dial of the operation panel or RS485 or UP/DOWN | ||
Multi-speed | Eight multifunction input terminals, 15section speed can be set | ||
Automatic voltage regulation | Automatic voltage regulation function can be selected | ||
Counter | Built -in 2group of counters | ||
Protection Warning Function | Overload | 150%,60 second(Constant torque);120%.60 second (variable torque) | |
Over Voltage | Over voltage protection can be set | ||
Under Voltage | Under voltage protection can be set | ||
Other Protections | Overheat, short circuit, over current, and parameter lock and so on | ||
Environment | Ambient Temperature | -10ºC to 40ºC(non-freezing) | |
Ambient Humidity | Max.95%(non-condensing) | ||
Altitude | Lower than 1000m | ||
Vibration | Max. 0.5G | ||
Structure | Cooling Mode | Forced air cooling | |
Protective Structure | IP20 | ||
Installation | Mode | Below 90KW:Wall Mounted; 110~200KW:Wall Mounted or in Cabinet; Above 220KW:in Cabinet | |
Model | Input | Rated output Power(KW) | Drive capacity(KVA) | Output current | Overload Capacity(60s)(A) | Applicable Motor(KW) |
S2100-4T5.5GE | Three phase380V.50/60Hz | 5.5 | 10 | 12.5 | 15 | 5.5 |
S2100-4T7.5GE | 7.5 | 14 | 17.5 | 21 | 7.5 | |
S2100-4T11GE | 11 | 19 | 24 | 28.8 | 11 | |
S2100-4T15GE | 15 | 26 | 33 | 39.6 | 15 | |
S2100-4T18.5GE | 18.5 | 32 | 40 | 48 | 18.5 | |
S2100-4T22GE | 22 | 37 | 47 | 56.4 | 22 | |
S2100-4T30GE | 30 | 52 | 65 | 78 | 30 | |
S2100-4T37GE | 37 | 64 | 80 | 96 | 37 | |
S2100-4T45GE | 45 | 72 | 90 | 108 | 45 | |
S2100-4T55GE | 55 | 84 | 110 | 132 | 55 | |
S2100-4T75GE | 75 | 115 | 152 | 182.4 | 75 | |
S2100-4T90GE | 90 | 135 | 176 | 264 | 90 | |
S2100-4T110GE | 110 | 160 | 210 | 252 | 110 | |
S2100-4T132GE | Three phase 380V.50/60Hz | 132 | 193 | 255 | 306 | 132 |
S2100-4T160GE | 160 | 230 | 305 | 366 | 160 | |
S2100-4T185GE | 185 | 260 | 340 | 408 | 185 | |
S2100-4T200GE | 200 | 290 | 380 | 456 | 200 | |
S2100-4T220GE | 220 | 320 | 425 | 510 | 220 | |
S2100-4T250GE | 250 | 365 | 480 | 576 | 250 | |
S2100-4T280GE | 280 | 427 | 560 | 672 | 280 |