High Voltage Insulation Resistance Meter Insulation Tester 5kv Insulation Resistance Tester Meter

China High Voltage Insulation Resistance Meter Insulation Tester 5kv Insulation Resistance Tester Meter, Find details about China Megger Meter, Test Meter from High Voltage Insulation Resistance Meter Insulation Tester 5kv Insulation Resistance Tester Meter

Model NO.
GM-5KV
Temperature
0-40ºC
Relative Humidity
20-90%
Anti-Electric Field Interference Ability
2mA(50Hz)
Product Name
Adjustable Insulation Resistance Meter
The Short-Circuit Current of Test Power
10mA
Wide Resistance Range From
0.5mΩ ~ 200000mΩ
Offer Report
Yes
Wide Voltage Range
0.25kv, 0.5kv, 1kv, 2.5kv, 5kv, 10kv, 15 Kv /20kv
Trademark
WG Hipot
Transport Package
Wooden Case
Specification
315*240*155mm
Origin
Wuhan, China
HS Code
9030332000
Model NO.
GM-5KV
Temperature
0-40ºC
Relative Humidity
20-90%
Anti-Electric Field Interference Ability
2mA(50Hz)
Product Name
Adjustable Insulation Resistance Meter
The Short-Circuit Current of Test Power
10mA
Wide Resistance Range From
0.5mΩ ~ 200000mΩ
Offer Report
Yes
Wide Voltage Range
0.25kv, 0.5kv, 1kv, 2.5kv, 5kv, 10kv, 15 Kv /20kv
Trademark
WG Hipot
Transport Package
Wooden Case
Specification
315*240*155mm
Origin
Wuhan, China
HS Code
9030332000
I.Equipment Description:
  Digital High Voltage Insulation Resistance Test Set 5kv 10kv 15kv 20kv
High Voltage Insulation Resistance Meter Insulation Tester 5kv Insulation Resistance Tester Meter
1.Product Description
GM-5KV Adjustable Insulation Resistance Meter   

For safety, before use the instrument must be well earthed. That's because the measured target connects to high voltage power, and exists power frequency leakage.
Once high voltage has started, do not use manual discharge method to check the instrument. After test, please wait the instrument completes automatic discharge and automatically returns to zero, then manual discharge can be operated. That is because electrical pulse caused by short-circuit discharge will damage the insulation life of the measured object; if the pulse fleeing into the instrument, will also damage the integrated circuit inside the instrument.
The instrument is designed for HV substations and power plants to test the characteristic of large HV transformer, electric machines and appliances, remote power cable or buried cable and other electrical insulation resistance in strong interference environment. It also can be widely used for testing characteristics of insulation resistance in other area. 

2. Features
1). With strong anti-electric field interference ability up to 2mA (50Hz), it is suitable for 500kV substation without dismantling wire to test insulation resistance of 500kV large-scale transformer.
2). The short-circuit current of test power 10mA. Be suitable for testing high capacity and high inductance.
3). Wide resistance range from 0.5MΩ ~ 200000MΩ. With high-resolution, having accurate readings.
4). Wide voltage range: 0.25kV, 0.5kV, 1kV, 2.5kV, 5kV, 10kV, 15 kV /20kV, you can smoothly adjust voltage from 0V to the desired value.
5). With timekeeping function, remind users to record, and analyze absorptance and polarization index of measured target.

3. Parameters
1. Technique specifications

ModeTest voltageVoltage accuracyShort-circuit current
GM-5kV0.25,0.5,1,2.5,5kV±(5%+10V)10mA
GM-10kV0.5,1,2.5,5,10kV±(5%+10V)10mA
GM-15kV1,2.5,5,10,15kV±(5%+10V)10mA
GM-20kV0.5,1,2.5,5,10,20kV±(5%+10V)10mA

2. Range and accuracy
 
RangeResistance measurement rangeAccuracy
20MΩ/500V0.5~19.99  MΩ±(5%+5digital)
200MΩ/1000V5.0~199.9  MΩ±(5%+5digital)
2GΩ0.05~1.999 GΩ±(5%+5digital)
20GΩ0.5~19.99  GΩ±(5%+5digital)
200GΩ5.0~199.9  GΩ±(10%+10digital)
2000GΩ50~1999  GΩLess than 1000GΩ ± (20% + 10 digital) (humidity ≤70%)

Calibration voltage of MΩ range is 0.5kV; Calibration voltage of GΩ range is 2.5kV
 
Anti-electric field interference ability2mA(50Hz) 
Timekeeping and alarm functionmaximum value of stopwatch is 19 minutes and 59 seconds. 20 minutes for a cycle. The stopwatch will tell the time at these time points: 15 seconds, 60 seconds and every 60 seconds. When telling time, resistance readings hold for 5 seconds. If the measured resistance is below the lower limit of range, the reading is invalid and the instrument will continuously sound to give an alarm
Displaythree and a half bits LCD digital meter (three), respectively show test voltage, test resistance, test time
Power supply10×1.2Vbattery(2000mAh Ni-MH rechargeable battery), total DC12V power supply
AC: 220V (50/60Hz)
Operating ConditionsTemperature:0~40ºCRelative humidity:20~90%
Dimension315×240×155mm3
Weight5kg

II.Company Profile: 

Wuhan WG Hipot Electric Tester Co.,Ltd. (hereafter referred to as WG Hipot) is the professional factory of high voltage testing equipment with over 15 years industry experience. 

ISO Certified factory, qualified R&D and after-sales Engineer team, 3000 square meters workshop, our high voltage testers cover full range: High voltage hipot tester, Circuit breaker Switchgear Tester, Transformer tester, Relay Protection Tester, CT/PT Tester, MOA/Insulator Tester, SF6/Insulation Oil Test Equipment, Resistance Tester, etc.

Since 2003, with the support from our investors Wuhan High Voltage Institution and Xi'an High Voltage Institution, WG Hipot established and pioneered in high voltage testing field in domestic market as the designated supplier for State Grid and mainstream power companies. 

Meantime, WG Hipot has developed overseas markets across 5 continents worldwide. We gained good feedback from our customers with our high performance, good quality, customized specification and easy-to-operate high voltage testers, which can be widely used in railway, oil and chemical industry, electricity grid, university, big factory etc.

High Voltage Insulation Resistance Meter Insulation Tester 5kv Insulation Resistance Tester MeterIII.Customer Visit: 
High Voltage Insulation Resistance Meter Insulation Tester 5kv Insulation Resistance Tester Meter
IV.Filed Test&Service:
High Voltage Insulation Resistance Meter Insulation Tester 5kv Insulation Resistance Tester MeterV.Certification:
High Voltage Insulation Resistance Meter Insulation Tester 5kv Insulation Resistance Tester MeterVI.Package & Shipment:

High Voltage Insulation Resistance Meter Insulation Tester 5kv Insulation Resistance Tester MeterHigh Voltage Insulation Resistance Meter Insulation Tester 5kv Insulation Resistance Tester Meter
VII. FAQ
1.When can I get the price?
We usually quote within 6hours after we get your inquiry. If you are vey urgent to get price, please call us or tell us in your email so that we will regard your inquiry priority.
2. What about the leading time for production?
Honestly, it depends on the order quantity and the product. Usually our leading time is within 7 working days after order confirmed.
3. What is your payment terms?
We accept EXW,FOB, CFR, CIF, ect. You can choose the one which is the most convenient and cost effective for you.
4. How much will be the Shipping cost and time?
This will depend on the size of your goods and the method of shipping (by sea/ by air/by Express) and your designated port or airport. We will be grateful if you can spare us some minutes to evaluate the cost based on the information provided.
5. Could you please tell me the Warranty Period of your product?
Our warranty period is one year free and lifelong maintenance. If the product is damaged (if not man-made damage), in the first year,we will send free parts for replacement. Over warranty, maintenance is paid service.
6. What kind of Certificate can you provide?
We can provide the CE mark, ISO 9001 quality certificate, third party calibration certificate(CNAS) and factory test report.
7. Do you have Technical Backup to all customers from different countries?
To be sure,our technical support is always available and quick response.
We are manufacturer with much on-site testing experience, thus we know how to deal with your problems. Moreover, our engineers can go to your country to support if need.