China FTTH Sc Upc APC Fiber Fast Connector, Find details about China Fast Connector, Fiber Optic from FTTH Sc Upc APC Fiber Fast Connector
Optical Fast Connector Optical Performance (Reference to China Standard Q/CT 2299-2010-6.1) | Unit( dB) | |||||
Code | Test Item | Mechanical Q/CT 2299-2010-Chapter6.1 | Fusion Splicer Type YD/T 2341.2-2011-Chapter 4.7 | |||
Average Value | Maximum Value | Average Value | Maximum Value | |||
a | Insertion Loss | ≤0.3 | Tested with standard plugs and adapters:≤0.5 Test with any plug and adapter:≤0.7 | ≤0.25 | Tested with standard plugs and adapters:≤0.4 Test with any plug and adapter:≤0.7 | |
b | Return Loss | ≥40(UPC);≥55(APC) | ≥50(UPC);≥60(APC) | |||
Mark1: IL and RL Test at 1310nm. If need test 1550nm, Please tell us first. Mark2:IL and RL average and Maximum vale make as customer's requirement. Mark3:Return Loss can customized UPC standard -45~-50dB;APC Standard -55~-60dB |
Optical Fast Connector mechanical character (Reference to standard Q/CT 2299-2010-6.3) | Unit( dB) | |||||
ITEM | Tet Name | Test conditions | Judgement Standard | |||
Insertion Loss Variation | Test Result | |||||
Mechanical | Fusion Splicer | |||||
a | Repeatable Assemblability | Assemblability Times: 5 Times | ≤0.3 | No Requirement | No mechanical damage, no obvious scratches on the pin surface | |
b | vibration | frequency: 10-50Hz Sweep frequency:45 Times per minute Amplitude: 0.75mm Single Amplitude Time:Three director ,each 2 hours | ≤0.3 | ≤0.25 | No mechanical damage, such as deformation, cracking, slack, etc. | |
c | Drop | Height:1.5meter from sample head Test times: 8 Times | ≤0.3 | ≤0.25 | No mechanical damage, such as deformation, cracking, slack, etc | |
d | Repeat Plug | Plug Times: 10 | ≤0.3 | ≤0.25 | No mechanical damage, such as deformation, cracking, slack, etc | |
e | mechanical Durability | Plug Times: 500 | ≤0.3 | ≤0.25 | No mechanical damage, such as deformation, cracking, slack, etc | |
f | Tensile | Telcom Standard Q/CT 2299-2010-7.14: 0.125mm bare fiber: 4N, No online monitoring of Optical performance; 0.25mm fiber type :4N No online monitoring of Optical performance; 0.9mm fiber type :10N online monitoring of Optical performance; Fiber optic cable :20N online monitoring of Optical performance; Fiber optic cable :30N No online monitoring of Optical performance;; Time:2 Minute | ≤0.3 | ≤0.25 | No mechanical damage, such as deformation, cracking, slack, etc | |
j | Tensile | Communication Standard YD/TT 2341.1-2011-5.15 Load weight:250μm fiber: 4N 900μmFiber : 10N Fiber optic cable 2.0mm and drop cable :20N Fiber optic cable 3.0mm: 50N; Load Time: fiber 30s,fiber optic cable 2min; Load rate: 50N/min<Rate<250N/min; The distance between the load point and the mechanical field connector: L=22cm~28cm | ≤0.3 | ≤0.20 | No mechanical damage, such as deformation, cracking, slack, et | |
g | Twist | Load Weight:Fiber Optic cabel 15N Rate: 10 Times/Minute times: 200Times | ≤0.3 | ≤0.25 | No mechanical damage, such as deformation, cracking, slack, et | |
Mark 1: Fusion Splicer type can not be repeatable assembly test; Mark 2:Repeat assembly testing is Mainly assess the deterioration of the amount of insertion loss. It requirment insersion loss deterioration ≤0.3. If insersion loss become better,then it is qualified ; Mark 3:After Test, Return Loss Variation≤5dB |
Item | ||
a | Operating temperature | -40ºC ~+85ºC |
b | Storage temperature | -40ºC ~+85ºC |
c | Relative humidity | ≤95%(+30ºC hours) |
d | Atmospheric pressure | 62kPa~106kPa |