Soil Resistivity Resistance Tester for Voltage Earth Ground Resistance Tester

China Soil Resistivity Resistance Tester for Voltage Earth Ground Resistance Tester, Find details about China Soil Resistivity Resistance, Earth Resistance Tester from Soil Resistivity Resistance Tester for Voltage Earth Ground Resistance Tester

Model NO.
HT3001
Pressure Resistance
AC 3700V/RMS
Trademark
HOTOTECH
Transport Package
Carton
Specification
277.2*227.5*153mm
Origin
Guangdong, China
Model NO.
HT3001
Pressure Resistance
AC 3700V/RMS
Trademark
HOTOTECH
Transport Package
Carton
Specification
277.2*227.5*153mm
Origin
Guangdong, China
Soil Resistivity Resistance Tester for Voltage Earth Ground Resistance Tester
1.Range and Accuracy error
Measurement functionMeasurement rangeAccuracyResolution
Grounding resistance
(R)
0.00Ω~30.00Ω±2%rdg±5dgt (remark 1)0.01Ω
30.0Ω~300.0Ω±2%rdg±3dgt0.1Ω
300Ω~3000Ω±2%rdg±3dgt
3.00kΩ~30.00kΩ±2%rdg±3dgt10Ω
Soil resistivity
(ρ)

 
0.00Ωm~99.99Ωmρ=2πaR (remark 2)0.01Ωm
100.0Ωm~999.9Ωm0.1Ωm
1000Ωm~9999Ωm1Ωm
10.00kΩm~99.99kΩm10Ωm
100.0kΩm~999.9kΩm100Ωm
1000kΩm~9999kΩm1kΩm
Grounding voltageAC 0.00~100.0V±2%rdg±3dgt0.01V
Soil Resistivity Resistance Tester for Voltage Earth Ground Resistance Tester
2.General specification
FunctionTwo three four-wire measure grounding resistance, soil resistivity;
Ground voltage, AC voltage measurement
Ambient temperature and humidity23ºC±5ºC,below 75%rh
PowerDC 6V 4.5Ah lead-acid battery lasts more than 100 hours standby
Interference voltage<20V (should be avoided)
Interference current<2A (should be avoided)
Measure R electrode spacinga>5d
Measured electrode spacinga>20h
Auxiliary ground resistanceReference condition <100Ω, working condition <5kΩ
RangeGrounding resistance: 0.00Ω~30.00kΩ
Soil resistivity: 0.00Ωm~9999kΩm
Grounding voltage: 0.00V~100.0V
measurement modePrecise four-wire, three-wire measurement, simple two-wire measurement
Measurement methodsGrounding resistance: rated current change pole method
Soil resistivity: four-pole method
Ground Voltage: Average Rectification(between S-ES interface)
Test frequency128Hz
Short circuit test current> 20mA (Sine Wave)
Open circuit test voltageAC 28V max
Electrode spacing rangeCan be set 1m ~ 100m
Change gearfully automatic shifting 0.00Ω ~ 30.00kΩ
fully automatic shifting 0.00 Ωm~9000kΩm
BacklightControllable gray screen backlight, suitable for use in dim places
Display mode4-bit large LCD display, gray screen backlight
Measurement instructionsLED flashing indicator during measurement
LCD size111mm×68mm
LCD display field108mm×65mm
Instrument sizeL/W/H:277.2mm×227.5mm×153mm
Standard test line length4 strips:red 15m,black 15m, yellow 10m,green 10m each one
Simple test line2strips:yellow 1.6m,green 1.6m each one
Auxiliary Grounding rod4PCS:φ10mm×200mm
Measure timeGround voltage:about 3 times/sec;
grounding resistance,soil resistivity: about 7 seconds/time
Line voltageMeasurement below AC100V (ground voltage measurement function cannot be used to measure commercial power)
USB interfaceWith USB interface, software monitoring, storage data can be uploaded to the computer, save and print
Communication LineOne USB communication line, 1.5m long
Data storage500 groups, "MEM" storage indicates, flashing "FULL" symbol indicates that the memory is full
Data reviewData review function: "MR" symbol display
Overflow displayOver-range overflow function: "OL" symbol display
Interference testAutomatic identification of interference signals, "NOISE" symbol indication when the interference voltage is higher than 5V
Auxiliary grounding testWith auxiliary ground resistance test function, 0.00KΩ ~ 30kΩ (Rh max = 3kΩ +100R <50kΩ; Rs max = 3kΩ +100R <50kΩ)
Alarm functionAlarm when the measured value exceeds the alarm setting value
Battery voltageReal-time display of battery power, reminding timely charging when battery voltage is low
Automatic Shutdown"APO" Indicates, automatic Shutdown After 15 Minutes
Power consumptionStandby: 40mA Max(Backlight off)
Turn on backlight: about 43mA
measuring:75mA Max(Backlight off)
WeightInstrument: 2450(including battery)
Test lines:1300g
Auxiliary grounding rod: 850g(4PCS)
Working temperature and humidity-10ºC~40ºC;below 80%rh
Storage temperature and humidity-20ºC~60ºC;below 70%rh
Overload protectionGrounding resistance:AC 280V/3 seconds between H-E and S-ES ports
Insulation resistanceMore than 20MΩ(500V between circuit and housing)
Pressure resistanceAC 3700V/rms(between circuit and housing)
Electromagnetic propertiesIEC61326(EMC)
Suitable for safety regulationsIEC61010-1(CAT III 300V,CAT IV 150V,pollution level
 2);
IEC61010-031;
IEC61557-1(grounding resistance);
IEC61557-5(soil resistivity);
JJG 366-2004.
Soil Resistivity Resistance Tester for Voltage Earth Ground Resistance Tester
Soil Resistivity Resistance Tester for Voltage Earth Ground Resistance Tester
Soil Resistivity Resistance Tester for Voltage Earth Ground Resistance Tester
Soil Resistivity Resistance Tester for Voltage Earth Ground Resistance Tester
Soil Resistivity Resistance Tester for Voltage Earth Ground Resistance Tester
Soil Resistivity Resistance Tester for Voltage Earth Ground Resistance Tester
Soil Resistivity Resistance Tester for Voltage Earth Ground Resistance Tester
Soil Resistivity Resistance Tester for Voltage Earth Ground Resistance Tester