Model NO.
Bell-AFA
Connection Type
Radial Direction
Function
Local Indication Type, Electric Signal-controlled
Installation Structure
Direct Mounting
Features of Measurement Medium
General Pressure Gauge
Indicating Pressure Reference
General Pressure Gauge
Structure.
Spring Pressure Gauge
Function.
Electric Signal-Controlled
Application.
Industrial
Diaphragm
Ss316
Mounting
Bottom with Connection or with Flange
Socket
Brass, Ss
Pressure Range
0-0.1~10 MPa
Trademark
Tianjin U-ideal Instrument
Specification
CE, ROHS, SGS, GMP
Origin
Tianjin, China
HS Code
9026209090
Model NO.
Bell-AFA
Connection Type
Radial Direction
Function
Local Indication Type, Electric Signal-controlled
Installation Structure
Direct Mounting
Features of Measurement Medium
General Pressure Gauge
Indicating Pressure Reference
General Pressure Gauge
Structure.
Spring Pressure Gauge
Function.
Electric Signal-Controlled
Application.
Industrial
Diaphragm
Ss316
Mounting
Bottom with Connection or with Flange
Socket
Brass, Ss
Pressure Range
0-0.1~10 MPa
Trademark
Tianjin U-ideal Instrument
Specification
CE, ROHS, SGS, GMP
Origin
Tianjin, China
HS Code
9026209090
Most Accurate Pressure Gauge- Diaphragm Pressure Gauge-Angle Connection Pressure Gauge
Working principle
The measured medium pressure P produced to diaphragm, and diaphragm appear deformation, compress pressure gauge sealing liquid, and generate P-DP pressure. If the rigid good enough, then DP is small. Then the measure pressure is similar to the measure medium pressure.

Diaphragm gauge liquid level difference
More than other type, the diaphragm gauge with soft tube type, due to the pressure sensing part installation position is different than ordinary type, this type will create liquid level difference influence value P.

Diaphragm-seal pressure gauge
Diaphragm pressure gauge the temperature influence is related to the amount of sealing liquid expanding coefficient diaphragm stiffness and affected by the temperature of the pressure parts. When the temperature deviated from 20+/- 5 ° C, rigid rod influence <0.1% ° C, and soft type (remote mounting type) influence is < 0.1%+/-0.025L% ° C, (L - pressure conduit length m). Diaphragm type pressure gauge's sealing liquid should be choose carefully according to the different environment.
The choice of sealing liquid
To ensure the diaphragm pressure gauge reliability and safety, should select a suitable sealing liquid according to different application.
seal liquidpressure part
temperature
density
g/cm 3
coefficient
expansion 1/°C
Service
High viscosity
silicone oil
-10~200  °C1.070. 95X10 3high
temperature
low viscosity silicone oil-30~100 °C0. 941.08X10- 3ordinary
glycerin liquor-5~100 °C1.270. 61X10 3food
Plant Oil-5~100 °C0. 931.03X10- 3food
fluorocarbon oil-30~150 °C1.930. 75X10- 3oxygen,
hydrogen

The choice of the diaphragm part corrosion resistant material
Corrosive
fluid
anti-corrosion material
tin-bronze
(QSn6.5-0.4)
SUS316(Ta)Monel
(Ni70Cu30)
hastelloy
(HG)
PTFE
(F4)
sulphuric
(H2S04)
VDOVVV
Nitric
(hno3)
XVOXVV
(HCL)DXOXVV
Phosphoric
(H3P04)
VVOVVV
acetic
(CH3C00H)
VVOVOV
NaOHDODOOV
(Na2CO3)OOOOVV
NaHCO3VOOOOV
CL2dry:V  wet:Xdry:V wet: XOdry:V  wet: XVV
Br2dry: D  wet:Xdry:X wet: DOdry:O wet: XOV
NH3XVXXOV
Sea water
(30%NaCL)
VVOOOV
Instruction: OBest   Dconditional use   V_usable     X_ unusable