Wx8000 Power Transformer Capacitance Dielectric Loss Tan Delta Tester Tan Delta Testing Machine

China Wx8000 Power Transformer Capacitance Dielectric Loss Tan Delta Tester Tan Delta Testing Machine, Find details about China Tan Delta Tester, Hipot Tester from Wx8000 Power Transformer Capacitance Dielectric Loss Tan Delta Tester Tan Delta Testing Machine

Model NO.
WX8000
Usage
Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer
Frequency Characteristics
Power Frequency
Shape of Core
Ring
Brand
Wg Hipot
Model No.
Wx8000
CVT Range
10~10000
Resolving Power
0.01
Self-Excited Power
AC 0V∽50V/15A
Accuracy
0.1%
Weight
28kg
Anti-Interference Principle
Frequency Conversion
Cx Resolution
0.001PF
Environment Temperature
-10~50 Degree
Printer
Wh-A7 Mini-Type Thermal Printer
Computer Interface
Standard RS232 Interface
Input Power Supply
220V AC, 50Hz
Measuring Duration
36s
Relative Humidity
<90%
Trademark
WG HIPOT
Transport Package
Wooden Box
Specification
460*360*350mm
Origin
China
Model NO.
WX8000
Usage
Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer
Frequency Characteristics
Power Frequency
Shape of Core
Ring
Brand
Wg Hipot
Model No.
Wx8000
CVT Range
10~10000
Resolving Power
0.01
Self-Excited Power
AC 0V∽50V/15A
Accuracy
0.1%
Weight
28kg
Anti-Interference Principle
Frequency Conversion
Cx Resolution
0.001PF
Environment Temperature
-10~50 Degree
Printer
Wh-A7 Mini-Type Thermal Printer
Computer Interface
Standard RS232 Interface
Input Power Supply
220V AC, 50Hz
Measuring Duration
36s
Relative Humidity
<90%
Trademark
WG HIPOT
Transport Package
Wooden Box
Specification
460*360*350mm
Origin
China

Product Description

WX8000 Power Transformer Capacitance Dielectric Loss Tan Delta Tester/Analyzer

Introduction:
Dielectric loss test is a basic method in insulation test and effectively detect damp, degradation and partial defect of insulation of electrical equipment. This method is widely used in electric manufacturing, electric equipment installation, connection and preventive test. Measurement on dielectric loss of transformer, mutual inductor, reactor, capacitor, bushing and arrester is the most basic method to test their insulation property. Fully-automatic anti-interference dielectric loss tester breaks through the traditional bridge testing method and adopts variable frequency power technology, single chip and modernized electrical technology to carry out automatic frequency shift, analog-to-digital conversion and data computing. It features strong anti-interference capacity, high test speed, high precision, automatic digitization and easy operation. It adopts high-power switching power supply, which outputs 45Hz and 55Hz pure sine wave and automatically increase the voltage to a maximum value 10 KV. It can filter 50Hz interference automatically, and it is applicable to the site test of substation and other places with large electromagnetic interference. This methods is extensively applied in dielectric loss measurement of transformer, mutual inductor, reactor, bushing, capacitor, arrester and others equipment in power industry.


Features:
1.The instrument adopts complex number current method to measure capacitance, dielectric loss and other parameters.
2.The instrument adopts variable frequency technology to eliminate 50Hz/60Hz power frequency interference. 
3.The instrument adopts large screen LCD. 
4.The instrument is easy to operate and the measuring process is controlled by microprocessor.
5.The instrument is designed to be an integrated model with reference capacitor and HV power supply in it, enables site test measurement and reduces site wiring. 
6.The instrument is equipped with CVT testing function, which can achieve CVT self-exciting testing without external accessories and measure the capacitance and dielectric loss of C1 and C2 by at a time. 
7.GST measurement adopts ivddv technology and avoids unstable data provided by previous GST measurement.
8.The instrument provides low voltage shell function of GST. When the bus of 220kV CVT is grounded, dielectric loss measurement can be conducted for C11 without removing 10 kV GST.
9.The instrument has a function of measuring high-voltage dielectric loss. 
10.The instrument has a ground-fault protection function. In case that the instrument is not grounded or grounded incorrectly, the instrument will refuse to enter into normal procedure and output HV.
11.The instrument has a function of electric shock protection.

Product Parameters

AccuracyCx:±(reading×1%+1pF)
tgδ: ±(reading×1%+0.00040)
Anti-interference:Variable frequency anti-interference, the above accuracy can be reached under 200% interference.
Capacitance rangeInternal HV: 3pF~60000pF/10kV 60pF~1μF/0.5kV
External HV: 3pF~0.5μF/10kV; 60pF~10μF/0.5kV
ResolutionMaximum 0.001pF, 4 valid figures.
tgδ range:unlimited, 0.001% resolution, automatic identification for capacitance, inductance and resistance of three tested articles.
Test current range10μA~1A
Internal HV: Set voltage range: 0.5~10kV   Voltage resolution : 1V   Accuracy: 2%
Maximum output current: 200mA
Buck-bust method: continuous step-less regulation
Test frequency45, 50, 55, 60, 65 Hz single frequency
45/55, 55/65Hz, 47.5/52.5Hz Hz automatic dual
variable frequency
Frequency accuracy: ±0.01Hz
External HV: In case of UST, maximum test current is 1A, and power frequency or variable frequency is 40-70Hz
CVT self-exciting low voltage output: Output voltage 3~50V, output current 3~30A
Measuring durationAbout 36s, depending on measuring method
Input power supply220V AC, 50Hz±1%, supplied by alternating current or generator
Computer interfaceStandard RS232 interface
PrinterWH-A7 mini-type thermal printer
Environment temperature-10ºC~50ºC
Relative humidity<90%
Dimension460×360×350mm
Weight28kg

 

Packaging & Shipping

Wx8000 Power Transformer Capacitance Dielectric Loss Tan Delta Tester Tan Delta Testing MachineWx8000 Power Transformer Capacitance Dielectric Loss Tan Delta Tester Tan Delta Testing Machine

Company Profile

Wx8000 Power Transformer Capacitance Dielectric Loss Tan Delta Tester Tan Delta Testing Machine
Wuhan WG Hipot Electric Tester Co.,Ltd. is the professional factory of high voltage testing equipment with over 15 years industry experience.

ISO Certified factory, qualified R&D and after-sales Engineer team, 3000 square meters workshop, our 
high voltage testers cover full range: High voltage hipot tester, Circuit breaker Switchgear Tester, Transformer tester, Relay Protection Tester, CT/PT Tester, MOA/Insulator Tester, SF6/Insulation Oil Test Equipment, Resistance Tester, etc.

Since 2003, with the support from our investors 
Wuhan High Voltage Institution and Xi'an High Voltage Institution, WG Hipot established and pioneered in high voltage testing field in domestic market as the designated supplier for State Grid and mainstream power companies.

Meantime, WG Hipot has developed overseas markets across 5 continents worldwide. We gained good feedback from our customers with our high performance, good quality, customized specification and easy-to-operate high voltage testers, which can be widely used in railway, oil and chemical industry, electricity grid, university, big factory etc.

 

Certifications

Wx8000 Power Transformer Capacitance Dielectric Loss Tan Delta Tester Tan Delta Testing Machine

Filed Test&After-Sales service

Wx8000 Power Transformer Capacitance Dielectric Loss Tan Delta Tester Tan Delta Testing Machine
1, Technical datas and operation manual sent for evaluation.
2, Tranining how to install and use the machine.
3, Engineers available to service machinery on site.

Customer Visit

Wx8000 Power Transformer Capacitance Dielectric Loss Tan Delta Tester Tan Delta Testing Machine

FAQ

1, Q: Are you manufacturer or trading company?
    A: We are manufacturer of more than 15 years in power testing products.

2, Q: How can the customer to pay?
    A: LC, TT, Western Union all accetable.

3, Q: Could CoulWhat's your terms of delivery?
    A: EXW, FOB, CFR, CIF All Acceptable. 

4, Q: Could you please tell me the Warranty Period of your product?
    A: Our warranty period is one year free and lifelong maintenance. If the product is damaged (if not man-made damage), in the first year,we will send free parts for replacement. Over warranty, maintenance is paid service.

5. Q: What kind of Certificate can you provide?
    A: We can provide the CE mark, ISO 9001 quality certificate, third party calibration certificate(CNAS) and factory test report.

6. Q:Do you have Technical Backup to all customers from different countries?
    A: To be sure,our technical support is always available and quick response.
We are manufacturer with much on-site testing experience, thus we know how to deal with your problems. Moreover, our engineers can go to your country to support if need.