Electrical Low Voltage Residual Current Circuit Breaker Knl7 -63

China Electrical Low Voltage Residual Current Circuit Breaker Knl7-63, Find details about China Residual Current Circuit Breaker, RCCB from Electrical Low Voltage Residual Current Circuit Breaker Knl7-63

Model NO.
KNL7-63
Poles Number
2, 4p
Type
Circuit Breaker
Function
RCCB
Certification
CB
Frame
63A
Rated Working Voltage
240/415
Rated Working Current
16;20;25;32;40;50;63A
Rate Limiting Short-Circuit Current
6000A
Mechanical Life
10000
Electric Life
4000
Trademark
korlen
Transport Package
Carton
Specification
CE
Origin
Wenzhou
Model NO.
KNL7-63
Poles Number
2, 4p
Type
Circuit Breaker
Function
RCCB
Certification
CB
Frame
63A
Rated Working Voltage
240/415
Rated Working Current
16;20;25;32;40;50;63A
Rate Limiting Short-Circuit Current
6000A
Mechanical Life
10000
Electric Life
4000
Trademark
korlen
Transport Package
Carton
Specification
CE
Origin
Wenzhou
KNL7 series Residual current circuit breaker(without over-current protection) is suitable for the line of A and S 50/60Hz, voltage 240V(2pole)/415V(4pole), rated current up to 63A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the power rapidly to protect human safety and prevent the accident due to the current leakage. It can be used as infrequent changeover of the line in normal situation. It is applicable to industrial site, commercial site, tall building and civil house. 
It complies with standard of IEC/EN61008.1 and GB16916.1. 

Each phase of conductor at the circuit breaker passes through the zero-sequence current transformer, and the secondary side of coil connects with the electromagnetic tripper. Under normal condition, the vector sum of each phase of current passing through zero-sequence current transformer is zero. The flux of the zero-sequence current transformer is zero. And the secondary output voltage is zero and the circuit breaker doesn't zero, and the zero-sequence current transformer would produce the magnetic flux, and the secondary side of coil would output the voltage. Once the leak current increases to drive the output voltage at the secondary side to grow to certain level, the electromagnetic release would activate to drive the operation mechanism to act to break the contact that connects the power, finally to realize the leak protection. 
Frame class63A
Rated working voltage240/415V
Rated frequency50/60Hz
Rated working current16, 20, 25, 32, 40, 50, 63A
Rated residual operating current0.03, 0.1, 0.3A
Rated residual un-operating current0.015, 0.05, 0.15A
SensibilityAC Type, A Type, S Type
Maximum operating timeIΔn t≤0.1s, 5IΔn t≤0.04
Rated making and breaking capacityIn≤50A 500A, In=63A 630A
Limiting value of un-operating current6In
Rated limiting short-circuit current6000A
Pole number2, 4P
Mechanical life10000


Electrical Low Voltage Residual Current Circuit Breaker Knl7-63
Electrical Low Voltage Residual Current Circuit Breaker Knl7-63
Company Introduction

Electrical Low Voltage Residual Current Circuit Breaker Knl7-63

Wenzhou Korlen Electric Appliances Co., Ltd, It is a joint venture. My company is a manufacturer including design, development, produce and sale, professional producing MCB, MCCB, RCCB and AC contactor etc. Product enterprises. The company owns import and export power of self-run, expanding Europe and America, Middle East, Southeast Asia etc. Market, set a good Public praise. 

The company have more than 1500 workers, including senior engineer among them, engineer at inside of more than 100 technician. And then set up to cover area more than 50 acres, construct area is more than 38000 square meters of the modern industrial zone, providing with the forerunner's standard laboratory and various examination equipments. 

Under Korlen people to make great effort unremittingly, designed and developed by oneself, develop and produce the series of MCB, RCCB filled up local blank, attain inter-national advanced level, and acquire more than 20 national patents. The company acquires "30 strong eminent enterprises, top ten of export income, yueqing star class enterprise, attach importance to contract and keeps promise" title of honor for many times past years. Company still the initiative pass ISO 9001 management system verification and 14001 environments management system verification. Our product passed quality verification of domestic and international authority organization like the CB\ SEMKO\ NF\ SIRIM\ SNI\ CE \PCT\ TSE, In the meantime high breaking capacity breaker of our company in this city is the unique product which got " Yueqing famous brand product" by Yueqing people government. 

Korlen Electric Appliances is willing to make friends with social public, the world outside businessman join hands together for prosperous society and development to build a brighter future. 



Certificates

Electrical Low Voltage Residual Current Circuit Breaker Knl7-63

Factory Lines

Electrical Low Voltage Residual Current Circuit Breaker Knl7-63
Electrical Low Voltage Residual Current Circuit Breaker Knl7-63

Exhibition

Electrical Low Voltage Residual Current Circuit Breaker Knl7-63


Electrical Low Voltage Residual Current Circuit Breaker Knl7-63


Electrical Low Voltage Residual Current Circuit Breaker Knl7-63
Electrical Low Voltage Residual Current Circuit Breaker Knl7-63