Bd Testing Pack

China Bd Testing Pack, Find details about China Bowie Dick Test Pack, Bowie-Dick Type Test from Bd Testing Pack

Model NO.
ULIFE
Sterilization Information Recording and Printing
Sterilization Information Recording and Printing
Material
Paper-Plastic
Size
115*125*20mm
Trademark
U-Life or OEM is welcome!
Transport Package
Carton
Specification
EN867-4
Origin
China
HS Code
90183100
Model NO.
ULIFE
Sterilization Information Recording and Printing
Sterilization Information Recording and Printing
Material
Paper-Plastic
Size
115*125*20mm
Trademark
U-Life or OEM is welcome!
Transport Package
Carton
Specification
EN867-4
Origin
China
HS Code
90183100
The Bowie Dick test pack makes the operator complete a right control of the autoclave and verify possible defects during Bowie Dick's cycle. It should be used daily, after a sterilizer is installed, relocated, after sterilizer malfunction, after sterilization process failures, and after any major repairs of the sterilizer.

Single use Bowie Dick autoclave test pack is characterized by the most reliable test such as;
1. Point out the presence of air leaks in the autoclave immediately and accurately;
2. Nontoxic ink and completely recycled materials;
3. EN867-4 certified;
4. Color Change: Easy to read colour change, once processed, the colour change is permanent and will not deteriorate over time;
5. CE certificate;
6. Free of lead;
7. Shelf life: 18 months sealed at room temperature;
8. The regular specification is as follow;
  Items  Size  Packing  Color change
  Bowie Dick test pack115*125mm 50pcs/box  Blue turn brown or black / Yellow turn brown or black
  Bowie Dick test card  210mm*297mm
(A4 paper size)
 250pcs/box  Blue turn brown or black / Yellow turn brown or black
  Bowie Dick test card 120*120mm
(1/4A4 paper size)
 250pcs/box  Blue turn brown or black / Yellow turn brown or black

(Notices)
1. The saturated stream pressure should reach to 0.4MPa 0.6MPa if air is supplied through pipe; And non-uniform color changes may be observed if the pressure is lower than 0.3MPa;
2. As for the pre-vacuum steam sterilizers or high vacuum autoclave with pulsing systems with air supply by pipe, the time of stopping air supply should longer than 2 days; And air-removal process should be done before re-using, or else, large amount of aqueous vapor existing in saturated stream may cause difficulty in cool air removal and wet pack, which will result in incapability of demonstrating test results due to wet BD test paper.

Bd Testing Pack