China Twintex Pch600-10HS Programmable 1000V DC Switching Low Current Variable High Voltage Power Supply, Find details about China High Voltage Power Supply, Variable Power Supply from Twintex Pch600-10HS Programmable 1000V DC Switching Low Current Variable High Voltage Power Supply
Model (600W) | Rated Output | Programming Resolution | Display Resolution | |||||
V | A | OVP | V | A | OVP | V | A | |
PCH600-10HS | 0~1000V | 0~600mA | 0~1050V | 1V | 0.1mA | 1V | 1V | 0.1mA |
PCH600-10HSN | -100~-1000V | 0~600mA | 0~-1050V | 1V | 0.1mA | 1V | 1V | 0.1mA |
PCH600-12HS | 0~1200V | 0~500mA | 100~1260V | 1V | 0.1mA | 1V | 1V | 0.1mA |
PCH600-12HSN | -120~-1200V | 0~500mA | -100~-1260V | 1V | 0.1mA | 1V | 1V | 0.1mA |
PCH600-15HS | 0~1500V | 0~400mA | 100~1575V | 1V | 0.1mA | 1V | 1V | 0.1mA |
PCH600-15HSN | -150~-1500V | 0~400mA | -100~-1575V | 1V | 0.1mA | 1V | 1V | 0.1mA |
PCH600-20HS | 0~2000V | 0~300mA | 200~2100V | 1V | 0.1mA | 1V | 1V | 0.1mA |
PCH600-20HSN | -200~-2000V | 0~300mA | -200~-2100V | 1V | 0.1mA | 1V | 1V | 0.1mA |
PCH600-30HS | 200~3000V | 0~200mA | 200~3150V | 1V | 0.1mA | 1V | 1V | 0.1mA |
PCH600-30HSN | -200~-3000V | 0~200mA | -200~-3150V | 1V | 0.1mA | 1V | 1V | 0.1mA |
Dimensions | 213Wx88Hx340D mm (1/2 2U) | |||||||
Weight | Approx 5kg | |||||||
AC Input | 1φ3W, 220V±10% 47~63Hz |
Output | ||
Rated Voltage | Full range adjustable | |
Rated Current | Full range adjustable | |
OVP Range | Up to 105% of rated voltage adjustable | |
Line Regulation | CV≤0.5%+2LSB, CC≤0.5%+2LSB | |
Load Regulation | CV≤0.1%+2LSB, CC≤0.1%+2LSB | |
Ripple & Noise | ≤0.1% FS | |
Programming | ||
Programming Resolution | Voltage | 1V |
Current | 0.1mA/ 1mA | |
OVP | 1V | |
Interface | RS232, RS485 and RS422 | |
Commands | ModBus-RTU | |
Display | ||
Meter | 4 1/2 digits LED display for voltage and current | |
Display Resolution | Voltage | 1V |
Current | 0.1mA/ 1mA | |
Display Accuracy | Voltage | ≤0.2%FS+2LSB |
Current | ≤0.5%FS+2LSB | |
Protection | ||
Over Voltage Protection (O.V.P.) | Built-in OVP protection with limit of 105% rated output voltage. The output will be shut down when OVP is activated. | |
Over Temperature Protection (O.T.P.) | Built-in OTP protection with heat sink temperature limit of 50ºC±5%. The output will be shut down when OTP is activated. | |
Under Voltage Protection (U.V.P.) | Built-in UVP protection with limit of 165Vac. The output will be shut down when UVP is activated. | |
General | ||
Cooling method | Cooling fan | |
Operating environment | 0ºC~40ºC, 10%~80%RH | |
Storage environment | -20ºC~70ºC, 10%~90%RH |