China 5celec 20 Ways RF 315 433 MHz Wireless to Wired Repeater Receiver Module for Door Sensor / PIR Rx-713, Find details about China Wireless Receiver, 433 Receiver from 5celec 20 Ways RF 315 433 MHz Wireless to Wired Repeater Receiver Module for Door Sensor / PIR Rx-713
5CELEC 20 Ways RF 315 433 MHZ wireless to wired repeater receiver module for door sensor / PIR RX-713o | ||||
Brand name | 5CELEC | Contact type | NO&NC | |
Model NO. | RX-713 | Dimensions | 80*36*26mm | |
Wireless protocol | RF | Max. supported sensors | 20 | |
Frequency | 433MHZ (others are available) | Working temperature | -20~60ºC | |
Coding chip | EV1527 | High level signal: | 7.1V | |
Transmitting Range | 100 Meter in open area | Low level signal: | 7.1v-0v | |
Working voltage | 9-35VDC | |||
Features 1,The RX-713 is wireless receiver base on RF wireless technology, which is used to receive the signal from wireless transmitter(door sensor, PIR) and convert to wired high-low voltage level signal; 2,The receiver has 20 ways independent signal output ports, can distinguish each transmitter and output with corresponding port. 3,(S1-S20) 20 maximum number of transmitter sensors supported by RX-713 receiver. | ||||
Networking& using 1,Click networking button---receiver get into networking mode, blue LED indicator flash twice each seconds, the wireless sensors can be matched when trigger at the moment. 2,In order to differentiate each sensors, the first matched sensor communicates with S1, the second matched sensor communicates with S2 , by parity of reasoning to S20 3,When the matched sensors more than 20 sets, the last sensor will cover the first sensor data. 4,If matched door sensor, when sensor is standby (door closed), receiver output high voltage signal, when sensor be triggerd(door open), receiver output low voltage signal. 5,If matched PIR detector, when detector is standby, receiver output high voltage signal, when it be triggered, receiver output low voltage signal, and back to high level if no re-trigger within 3seconds. 6,Press networking button 5 seconds, red LED light up, and release button ---clear all the matched sensors data. 7,LED indicator will flush 5 times quickly in 1 second , indicated sensor match successfully. the 5C-619 receiver will gets out the networking mode if there is no sensors be matched in 1 minute. | ||||
Wireless receiver(time delay) | Wireless water sensor | Wireless PIR motion sensor |