China Saj70-1.4 Freight Elevator Double Cage Passenger Hoist Construction Material, Find details about China Freight Elevator, Safety Equipment from Saj70-1.4 Freight Elevator Double Cage Passenger Hoist Construction Material
Recovery of the safety device:
Except for drop test, if the safety device braking happens, before recovery operation the safety device action reason should firstly be investigated, at the same time the followings should be identified
1) Whether the brake works normally.
2) Whether the turbine pair and the coupling work normally.
3) Whether the guide rolling wheel and support rolling wheels work normally.
4) Whether pinion and the rack work normally.
5) Whether position limited structure on the safety device work normally (when
inspection the electric circuit should be switched off).