Current Transformers MB0-100, 56*101 mm Inner Hole

China Current Transformers MB0-100, 56*101 mm Inner Hole, Find details about China Current Trannsformer, Ring Type Current Transformer from Current Transformers MB0-100, 56*101 mm Inner Hole

Model NO.
MBO
Insulating Medium
Epoxy Resin
Installation
Busbar Type
Voltage Transformation Principle
Capacitive Type
Frequency
50/60Hz
Rated Input
5-3000A
Measuring Range
5%Ln-120%Ln
Trademark
HEYI
Transport Package
Thick Cardboard Boxes
Specification
750/5A - 3000/5A
Origin
Wenzhou, Zhejiang, China
HS Code
8504311000
Model NO.
MBO
Insulating Medium
Epoxy Resin
Installation
Busbar Type
Voltage Transformation Principle
Capacitive Type
Frequency
50/60Hz
Rated Input
5-3000A
Measuring Range
5%Ln-120%Ln
Trademark
HEYI
Transport Package
Thick Cardboard Boxes
Specification
750/5A - 3000/5A
Origin
Wenzhou, Zhejiang, China
HS Code
8504311000
MBO Series (9 frames) perfect designed plastic case current transformer, advanced snap on body, high accuracy (up to Class 0.2S), humanization transparent cover and lead seal hole design makes the CT very easy to indentify after long term use and perfect anti-stealing electricity.
Current Transformers MB0-100, 56*101 mm Inner Hole

Features
1:Safe, easy to install, portable
2:Wide inner window, allowing clamping of big cables or bus-bars
3:Wide range of sizes to accommodate all the existing installations

Applications:
1:Current measurement, monitoring and protection for electrical wiring and equipment.
2:Current and power measurement for electric motors, lighting, air compressor, heating and ventilation system, air-condition equipment and automation - control system.
3:Current, power and energy monitoring device.
4:Relay protection device.

Technical Index:
Electrical ParameterMechanical Parameter
Frequency50/60HzCasePC/UL94-V0
Rated Input5A-3000ABobbinPBT
Measuring range5%In-120%InCoreSilicon steel
Rated Output1A,5AConstructionScrew
Ratio Voltage0.72KV (AC)Operating Temp-25ºC~+75ºC
Dielectric strength3.0KV/1mA/1minOperating Humidity≤85%
Insulation ResistanceDC500V/100MΩ minOutput ConnectionTerminal
Current Transformers MB0-100, 56*101 mm Inner Hole

Technical Parameter
ModelPrimary / SecondaryBusbar Hole Dimensions(mm)Rated Burden (VA)Accuracy ClassRated Voltage
MBO-62/B5/5A~200/5Abusbar2.5~50.5 / 1.00.72KV(AC)
MBO-62/2030/5A~200/5Aφ=20mm1.5~3.750.5 / 1.00.72KV(AC)
MBO-62/3030/5A~300/5Aφ=30mm1.5~50.5 / 1.00.72KV(AC)
MBO-62/4060/5A~400/5Aφ=40mm1.5~50.5 / 1.00.72KV(AC)
MBO-3050/5A~400/5Aφ=30mm1.5~50.5 / 1.00.72KV(AC)
MBO-40100/5A~600/5Aφ=40mm5~7.50.5 / 1.00.72KV(AC)
MBO-60300/5A~1500/5Aφ=60mm5~150.5 / 1.00.72KV(AC)
MBO-70400/5A~16000/5Aφ=70mm5~150.5 / 1.00.72KV(AC)
MBO-100750/5A~3000/5Aφ=100mm10~200.5 / 1.00.72KV(AC)