China Medical Equipment Hospital High Quality Pathological Analysis Patient Monitor, Find details about China Medical Equipment Patient Monitor, Hospital High Quality Patient Monitor from Medical Equipment Hospital High Quality Pathological Analysis Patient Monitor
Basic information:
6 parameters | ECG,HR,SPO2,NIBP,RESP, TEMP |
Size | 12.1 inch portable multi-parameter monitor |
Weight | 3 kg |
Voltage | 220v |
Power | 40w |
Leads | 3-5 leads |
Suitable places | pet clinic, pet hospital, veterinary station and zoo. |
Optional | Build-in thermal printer; lithium battery; mobile stand / wall mount |
SFDA classification | Class II |
Working system | Continuous running equipment |
Features:
12" color TFT display, up to 12 waveforms
Arrhythmia analysis, ST calculation, Pace analysis
Various interfaces: A single guide, standard, large font, all leads
Patient info input management function
Multi-lead ECG waveforms display in phase
1-7 level audio/visual alarming
Large volume of tabular and graphic trends information storage and easy to recall
Suitable for cat, dog and other mammals.
Built-in recorder and battery
Standard configuration:
PM-9000A+ pet monitor×1 set,
pet ECG clip joint connecting cables×1 set,
pet blood pressure cuffs×1 set,
pet SPO2 probe×1 set,
TEMP probe×1 set,
power plug line×1 PCS,
grounding wires×1 PCS,
English operation manual×1 set.
Optional:
Build-in rechargeable lithium battery; build-in thermal printer; monitor mobile stand/ cart.
Technical parameters:
ECG measurement:
Leads choices: All, I, II, III, aVF, aVR, aVL. V1--6 chest leads showed
Gains options: × 1, × 2, × 0.25, and × 0.5 four trenches
Frequency: 0.5 Hz - 100 Hz
Common-mode signal inhibition: More than 70 dB
Scan rate: 12.5 mm / S, 25 mm / S, 50 mm / S standard three stalls.
HR: ± 5 bpm
Precision calibration signal: 1mv(peak, ± 3% accuracy)
ST Detection: measurement range (-2.0mV----+2.0mV)
Using Standard: meet the ANSI / AMI EC13 -2002 standard
Response time: 1s
Alarm: Sound and Light
Preset heart rate range: (Alarm over preset numerical)
Ceiling: 1-255 bpm adjustable
Threshold: 0-254 bpm adjustable
NIBP measurement
Technology: Oscillography
Measuring method: negative measurement data is more accurate
Mode: manual / automatic
Measurement units: mmHg / kpa
Protection: Double security protection
A measurement time: less than 45 S
Scope: Pressure Cuffs 0-250 mmHg
Blood pressure measurement accuracy: ANSI /AAMI, SP10-2002 standard error and standard deviation of the average value of the initial
Inflatable cuffs: 180 mmHg (120 mmHg children newborn 70 mmHg)
Inflatable cuffs follow: original SBP: + 30 mmHg
Blood pressure measuring range:
Systolic blood pressure: 60-250 mmHg
Diastolic blood pressure: 40-220 mmHg
Pressure on the average: 45-235 mmHg
Response time: 1s
Alarm: Sound and Light
Preset range: report (Numerical exceed preset alarm)
Systolic blood pressure maximum: 1-255 mmHg adjustable
Threshold: 0-254 mmHg adjustable
Diastolic blood pressure ceiling: 1 -255 mmHg adjustable
Minimum standards: 0-254 mmHg adjustable
Use standard: compliance with the ANSI / AAMI SP10-2002 standard
Spo2 measurement
Range: 0-100%
Accuracy: 1%
Resolution: 1%
Pulse frequency: 20-250 times / min
Response time: 1s
Alarm: Sound and Light
Preset range: (report Alarm over preset numerical)
Ceiling: 1% - 100% adjustable
Threshold: 0% - 99% adjustable
TEMP measurement:
Technology: thermostat temperature probe
Measuring range: 20 ° C-45 ° C
Temperature resolution: 0.1%
Accuracy: ± 0.1 ° C
Response Time: 1s
Alarm: Sound and Light
Preset range: report (numerical preset alarm over)
Maximum: 20.1 ° C-45.5 ° C adjustable
Threshold: 20 ° C-45.4 ° C Adjustable
RESP Breath
Breathing frequency range: 0-60 bum
Accuracy: ± 1rpm
Response time: 1s
Gains options: × 1, × 2, × 4, and × 0.5 four trenches
Alarm: Sound and Light
Alarm range: (numerical preset alarm over)
Ceiling: 10-100 bpm adjustable
Threshold: 0 -99 bpm adjustable
Printer(Optional)
Specification: Dual channel thermal array data recorder
Print mode: Real time or event triggered record waveform and text
Accuracy: horizontal: 400dpi vertical: 800dpi
Annotation: time(24)
System
Display selection:12.1 inch color TFT true color LCD screen
Battery (optional): Lead-Acid battery sealed maintenance-free
Security labels: lec601-1 (International GB9706.1)