China Seer 19/21/25 DC Inverter Wall Mounted AC R410A 60Hz Cooling and Heating 9000/12000/18000/24000/30000 BTU Split Air Conditioner, Find details and Price about China Seer19, Inverter from Seer 19/21/25 DC Inverter Wall Mounted AC R410A 60Hz Cooling and Heating 9000/12000/18000/24000/30000 BTU Split Air Conditioner
Model | YAB-12HRFN1 | ||
Power supply | Voltage type | / | 208/230V,1Ph |
Supply frequency | / | 60Hz | |
Cooling | Capacity | Btu/hr | 12000 |
Capacity_Min | Btu/hr | 3700 | |
Capacity_Med | Btu/hr | 12000 | |
Capacity_Max | Btu/hr | 13000 | |
Cooling at 5F capacity(-15ºC) | Btu/hr | 13000 | |
Input | W | 1065 | |
Input_Min | W | 130 | |
Input_Med | W | 1065 | |
Input_Max | W | 1380 | |
Current | A | 4.5 | |
Current_Min | A | 0.6 | |
Current_Med | A | 4.8 | |
Current_Max | A | 6.0 | |
EER | W/W | 3.31 | |
EER_US | Btu/hr/W | 11.3 | |
SEER_US | Btu/hr/W | 19.5 | |
Heating | Capacity | Btu/hr | 12000 |
Capacity_Min | Btu/hr | 3500 | |
Capacity_Med | Btu/hr | 12000 | |
Capacity_Max | Btu/hr | 13500 | |
Heating at 17F capacity (-8.33ºC) | Btu/hr | 8800 | |
Input | W | 1025 | |
Input_Min | W | 150 | |
Input_Med | W | 1025 | |
Input_Max | W | 1450 | |
Current | A | 4.3 | |
Current_Min | A | 0.7 | |
Current_Med | A | 4.7 | |
Current_Max | A | 6.3 | |
COP | W/W | 3.43 | |
HSPF4 | Btu/hr/W | 10 | |
HSPF5 | Btu/hr/W | 8 | |
Max.Input consumption | Max.Input consumption | W | 2500 |
Max.Current | Max.Current | A | 11.5 |
Indoor sound pressure level(Hi/Mi/Lo/Si) | Indoor sound pressure level(Hi) | dB(A) | 38 |
Indoor sound pressure level(Mi) | dB(A) | 32 | |
Indoor sound pressure level(Lo) | dB(A) | 24 | |
Indoor sound pressure level(Si) | dB(A) | 23 | |
Outdoor sound pressure level(Hi) | Outdoor sound pressure level(Hi) | dB(A) | 55 |
Refrigerant piping | Liquid side | / | 6.35mm(1/4in) |
Gas side | / | 12.7mm(1/2in) | |
Max. refrigerant pipe length(single) | m | 25 | |
ft | 82.02 | ||
Max. difference in level | m | 10 | |
ft | 32.81 | ||
Suction design pressure(US) | psi | 340 | |
Discharge design pressure(US) | psi | 550 | |
Plug type | Plug type | / | no-plug |
Power cord type(Outdoor unit) | mm2 | 14#x3 | |
Connection wiring | Connection wiring type | mm2 | 16#x4 |
Control type | Control type | / | (Remote Control) |
Operation temperature | Indoor(Cooling) | ºC | 17~32 |
Outdoor(Cooling) | ºC | -15~43 | |
Indoor(Heating) | ºC | 0~30 | |
Outdoor(Heating) | ºC | -25~30 | |
Loading quantity 20'GP/40'GP/40'HQ | Loading quantity_20'GP | set | 84 |
Loading quantity_40'GP | set | 178 | |
Loading quantity_40'HQ | set | 214 |