Customed Packing Defibrillator

China Customed Packing Defibrillator, Find details about China Aed Defibrillator, Defibrillator from Customed Packing Defibrillator

Model NO.
D2000A
Anesthesia
Closed Circuit
Type of Operating Light
Double Operating Light
Energy Sequence
150,150,200j
Color
Yellow,Red,Blue,and Others
Name
Defibrillator Aed
Defibrillation Process
3 Steps
Output
Biophasy 20-200 Ohm
Net Weight
2.0kg
Trademark
Poweam
Specification
ISO, CE
Origin
Nanjing
HS Code
90181930
Model NO.
D2000A
Anesthesia
Closed Circuit
Type of Operating Light
Double Operating Light
Energy Sequence
150,150,200j
Color
Yellow,Red,Blue,and Others
Name
Defibrillator Aed
Defibrillation Process
3 Steps
Output
Biophasy 20-200 Ohm
Net Weight
2.0kg
Trademark
Poweam
Specification
ISO, CE
Origin
Nanjing
HS Code
90181930

customed packing Defibrillator (D2000A)

 
(1)Defibrillator type: Manual, Synchronized, Asynchronized 
(2)Energy accuracy: < 1% 
(3)Energy selection: 0, 3, 5, 7, 10, 20, 30, 50, 100, 200, 300, 360 joules (nominal at a resistance of 50)
(4)Charging time: Maximum 10 seconds to 360 Joules
(5)Standard Adult/Pediatric Paddles  Reusable external adult paddles (pediatric paddles integrated)  

7" color LCD display
Monophasic defibrillator / monitor
ECG
ECG lead: I, II, III,, a VR, a VL, a VF, V1-V6
S-T segment analysis: -2.0-2.0mv
Protection: withstand 4000v AV/50HZ voltage in isolation and work against lectrosurgical 
interence and defibrillation.
ECG lead/cable: general lead/cable for adult, pediatric and neonatal patients
Respiration
Measurement method: Thoracic impedance <o:p>
NIBP:
Method: automatic oscillation
Ement: pediatric: 10-200mmHg

Working mode: manual/automatic
Measur: adult: 10-250mmHg
Rabge: neonatal: 10-135mmHg
TEMP:
Measurement range: 20-45ºC
Resolution: 0.1ºC
SpO2:
Display: SpO2 value, pulse histogram, waveform, pulse
Range: 0-99% for adult, pediatric and neonatal patients
Probe: stand: adult finger clip Optional: pediatric Y-type clip and neonatal wrap<o:p>
Pulse:
Pulse range: 0-300bpm
Pulse accuracy: ±2bpm

 
ECG 
ECG lead I, II, III,, a VR, a VL, a VF, V1-V6
S-T segment analysis -2.0-2.0mv
Protection withstand 4000v AV/50HZ voltage in isolation and work against lectrosurgical 
interence and defibrillation.
ECG lead/cable general lead/cable for adult, pediatric and neonatal patients 
Respiration 
Measurement method Thoracic impedance
NIBP 
Method automatic oscillation
Working mode manual/automatic
Measur Adult 10-250mmHg
Ement Pediatric 10-200mmHg
Rabge Neonatal 10-135mmHg
TEMP 
Measurement range 20-45ºC
Resolution 0.1ºC
SpO2 
Display SpO2 value, pulse histogram, waveform, pulse
Range 0-99% for adult, pediatric and neonatal patients
Probe stand adult finger clip Optional pediatric Y-type clip and neonatal wrap
Pulse 
Pulse range 0-300bpm
Pulse accuracy ±2bpm


Customed Packing Defibrillator