Model NO.
UD10
Standby UPS
Sine Wave Output UPS
Output Capacity
Small Type
Equipment Mode
Centralized Model
Brand
Kstar
Trademark
KSTAR
Transport Package
Carton
Specification
250× 828× 868
Origin
China
HS Code
8504401990
Model NO.
UD10
Standby UPS
Sine Wave Output UPS
Output Capacity
Small Type
Equipment Mode
Centralized Model
Brand
Kstar
Trademark
KSTAR
Transport Package
Carton
Specification
250× 828× 868
Origin
China
HS Code
8504401990
Kstar Ud Series Online Double Conversion UPS System Uninterruptible Power Supply 10-80kVAKSTAR UD series online double conversion UPS System adopts advanced DSP control and N+X redundancy design to enhance the reliability. With high power factor (PF) and ECO mode operation for energy saving, UD series is the cost-effective choice in the industry. It has been widely used for server rooms, personal computers, data warehouses, medical clinics, industrial application and office facilities.
 
General Features

True double-conversion

Real-time digital signal processor (DSP) control

N+X parallel redundancy

Selectable quantity of battery for each group:for long run unit

Adjustable charging current via LCD

3-stage charging design optimizes battery performance

ECO mode operation for energy saving

Self-diagnosis at startup

Emergency power off function(EPO)

Maintenance bypass is convenient for maintenance

Generator compatible

Communications:RS-232,USB,SNMP card(Optional), Relay card (Optional)

Cold start

 
Technical Specification
 
MODEL UD10 / UD10LUD15 / UD15LUD20 / UD20LUD30 / UD30LUD40LUD60LUD80L
Capacity (VA/Watts)10K / 9K15K / 13.5K20K / 18K30K / 27K40K / 36K60K / 54K80K / 72K
INPUT 
Nominal Voltage380/400/415Vac(3Ph+N+PE)
Operating Voltage Range208~478Vac@half load; 305~478Vac@full load
Operating Frequency Range50Hz:45~55Hz,60Hz:54~66Hz
Power Factor≥0.99
 Max.voltage: 220V:+25%(Optional +10%,+15%,+20% )
Bypass Voltage Range230V:+20%(Optional +10%,+15%)
 240V:+15%(Optional +10% )
 Min. voltage: -45% (Optional -10%, -20%,-30%)
ECO RangeSame as bypass
Harmonic Distortion (THDi)≤3%(100% non-linear load)
OUTPUT 
Output Voltage380/400/415Vac(3Ph+N+PE)
Power Factor0.9
Voltage Regulation±1%
FrequencyLine Mode±1%/±2%/±4%/±5%/±10% of the rated frequency(Optional)
Bat. Mode50/60(1±0.1%)Hz
Crest Factor3:01
Harmonic Distortion (THDv)≤2% with linear load
≤5% with non-linear load
WaveformPure Sinewave
Transfer TimeUtility to Battery : 0ms; Utility to Bypass: 0ms
EFFICIENCY 
Efficiency95%
BATTERY 
BatteryStandard unit±120Vdc (20pcs 12V9AH)±120Vdc (2x20pcs 12V9AH)±120Vdc (3x20pcs 12V9AH)N/A
VoltageLong run unitSelectable Voltage:±96V/±108V/±120VdcSelectable Voltage:±192V/±204V/±216V/ ±228V/±240Vdc
ChargingStandard unit1.352.74.05N/A
Current (A)Long run unitMax.current 10AMax.current 15AMax.current 30A
PROTECTION 
 Line ModeLoad≤110%: last 60min, ≤125%: last 10min, ≤150%: last 1min, ≥150% turn to bypass mode immediately
OverloadBat. ModeLoad≤110%: last 10min, ≤125%: last 1min, ≤150%: last 5S, ≥150% shut down UPS immediately
 Bypass Mode20A(Input breaker)32A(Input breaker)40A(Input breaker)63A(Input breaker)80A(Input breaker)100A(Input breaker)125A(Input breaker)
Short CircuitHold Whole System
OverheatLine Mode: Switch to Bypass; Backup Mode: Shut down UPS immediately
Battery LowAlarm and Switch off
INDICATORS 
Audible & Visual AlarmsLine Failure, Battery Low, Overload, System Fault
Status LED & LCD DisplayLine Mode, Backup Mode, Eco Mode, Bypass Mode, Battery Low, Battery Bad, Overload & UPS Fault
Parameters On The LCD PanelInput/Output Voltage, Input/Output Frequency, Load Level, Battery Level, Inner Temperature & Remaining Battery Backup Time
MANAGEMENT 
Communication InterfaceRS-232,RS-485,USB,Parallel card, SNMP card(Optional), Relay card (Optional),Battery temperature sentor(optional)
ENVIRONMENT 
Operating Temperature0~40ºC
Storage Temperature-25~55ºC
Humidity Range0~95% (Non-condensing)
Altitude< 1500m
Noise Level<55dB<58dB<63dB
PHYSICAL 
Dimension W×D×H (mm)250×828×868360×828×868
Net Weight (kg)115/57170/63171/64223/7173118122
STANDARDS 
Noise SuppressionComplies with EN62040-2
SafetyIEC/EN62040-1,IEC/EN60950-1
EMCIEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,
IEC61000-4-5,IEC61000-4-6,IEC61000-4-8
Specifications are subject to change withour notice in advanced