China Low Frequency Industrial UPS 40kVA 60kVA 80kVA 100kVA 120kVA a UPS Price, Find details about China Low Frequency UPS, Online Smart UPS from Low Frequency Industrial UPS 40kVA 60kVA 80kVA 100kVA 120kVA a UPS Price
Online double conversion
Full DSP control
High power factor
Wide input adaptability
Optimized battery management
N+X parallel redundancy
Strong overload capability
Power walk in
Generator mode
Multi-protection
EPO function
User-friendly network management
MODEL | EP10 | EP20 | EP30 | EP40 | EP60 | EP80 | ||
Capacity (VA/Watts) | 10kVA / 9kW | 20kVA / 18kW | 30kVA / 27kW | 40kVA / 36kW | 60kVA / 54kW | 80kVA/ 72kW | ||
INPUT | ||||||||
Operating voltage range | 380/400/415Vac (-25% / +20% ), (3Ph+N+PE) | |||||||
Operating frequency range | 50/60Hz(±5%) | |||||||
Power Factor | >0.97 (with filter) | |||||||
OUTPUT | ||||||||
Output Voltage | 380/400/415Vac (±1%) | |||||||
Output frequency | 50/60Hz (±0.05%) | |||||||
Harmonic Distortion (THDv) | <3% with linear load | |||||||
Crest factor | 3:1 (max) | |||||||
Efficiency | ≥88% | ≥89% | ≥90% | ≥90.5% | ||||
BYPASS | ||||||||
Rated voltage | 380/400/415Vac | |||||||
Rated frequency | 50/60Hz | |||||||
Voltage protection range | Upper limit: +20% (+10%,+15%,+20% adjustable)Lower limit: -40% (-10%, -20%, -30%, -40% adjustable) | |||||||
Frequency protection range | ±10% (±2.5%, ±5%,±10%, ±20% adjustable) | |||||||
BATTERY | ||||||||
Battery voltage | 384Vdc ( 360~384Vdc ) | |||||||
SYSTEM FEATURES | ||||||||
Transfer time | 0ms (Line mode →Battery mode) | |||||||
Overload | ≤110%/60min ,≤125%/10min ,≤150%/1min,to Bypass | |||||||
LED display | Input, Inverter, Bypass, Battery, Output, Status | |||||||
LCD display | I/O voltage, frequency, power, power factor, battery voltage, current, battery status, load percentage, UPS status, history record | |||||||
Communication interface | Dry contact, RS232, RS485, SNMP card (Optional) | |||||||
Optional | Harmonic filter, SNMP adapter, LBS cables, battery temperature sensor,Bypass current-sharing inductor | |||||||
ENVIRONMENT | ||||||||
Operating Temperature | 0ºC~40ºC | |||||||
Storage temperature | -25~55ºC | |||||||
Humidity range | 0~95% (non-condensing) | |||||||
Altitude | <1500m | |||||||
Noise level | <60dB | <65dB | ||||||
PHYSICAL | ||||||||
Dimension W×D×H (mm) | 350×650×1050 | 430×830×1100 | 720×690×1600 | |||||
Net weight (kg) | 148 | 163 | 230 | 255 | 386 | 426 | ||
Shipping weight (kg) | 168 | 183 | 263 | 288 | 432 | 472 | ||
STANDARDS | ||||||||
Safety | IEC/EN62040-1;IEC/EN60950-1 | |||||||
Performance | IEC 62040-3 | |||||||
EMC | IEC/EN62040-2;IEC61000-4-2;IEC61000-4-3;IEC61000-4-4; IEC61000-4-5;IEC61000-4-6;IEC61000-4-8;IEC 61000-4-11; |
MODEL | EP100 | EP120 | EP160 | EP200 | EP300 | EP400 | EP500 | EP600 | EP800 | ||
Capacity (VA/Watts) | 100kVA / 90kW | 120kVA / 108kW | 160kVA / 144kW | 200kVA / 180kW | 300kVA / 270kW | 400kVA/ 360kW | 500kVA/ 450kW | 600kVA/ 540kW | 800kVA/ 720kW | ||
INPUT | |||||||||||
Operating voltage range | 380/400/415Vac (-25% / +20% ), (3Ph+N+PE) | ||||||||||
Operating frequency range | 50/60Hz(±5%) | ||||||||||
Power Factor | >0.97 (with filter) | ||||||||||
OUTPUT | |||||||||||
Output Voltage | 380/400/415Vac (±1%) | ||||||||||
Output frequency | 50/60Hz (±0.05%) | ||||||||||
Harmonic Distortion (THDv) | <2% with linear load | ||||||||||
Crest factor | 3:1 (max) | ||||||||||
Efficiency | ≥92% | ≥92.5% | ≥93% | ≥93.5% | ≥94% | ||||||
BYPASS | |||||||||||
Rated voltage | 380/400/415Vac | ||||||||||
Rated frequency | 50/60Hz (auto-sensing) | ||||||||||
Voltage protection range | Upper limit: +20% (+10%,+15%,+20% adjustable)Lower limit: -40% (-10%, -20%, -30%, -40% adjustable) | ||||||||||
Frequency protection range | ±10% (±2.5%, ±5%,±10%, ±20% adjustable) | ||||||||||
BATTERY | |||||||||||
Battery voltage | 384Vdc ( 360~408Vdc ) | 480Vdc | 600Vdc | ||||||||
SYSTEM FEATURES | |||||||||||
Transfer time | 0ms (Line mode →Battery mode) | ||||||||||
Overload | Load≤110%/60min ,≤125%/10min ,≤150%/1min,to Bypass | ||||||||||
LED display | Input, Inverter, Bypass, Battery, Output, Status | ||||||||||
LCD display | I/O voltage, frequency, power, power factor, battery voltage, current, battery status, load percentage, UPS status, history record, settings | ||||||||||
Communication interface | Dry contact, RS232, RS485, SNMP card (Optional) | ||||||||||
Optional | Harmonic filter, SNMP adapter, LBS cables, battery temperature sensor,Bypass current-sharing inductor | ||||||||||
ENVIRONMENT | |||||||||||
Operating Temperature | 0ºC~40ºC | ||||||||||
Storage temperature | -25~55ºC | ||||||||||
Humidity range | 0~95% (non-condensing) | ||||||||||
Altitude | <1500m | ||||||||||
Noise level | <65db | <70dB | |||||||||
PHYSICAL | |||||||||||
Dimension W×D×H (mm) | 890×775×1600(6P) 1515×830×1600(12P) | 1200×800×1600(6P) 1400×1000×1900(12P) | 1400×1000×1900(6P) 1640×1000×1900(12P) | 2580×1000×1900(500)12P 2800×1040×1900(600)12P | 3280×1040 ×1950(12P) | ||||||
Net weight (kg) | 625/1300 | 685/1450 | 1219/1774 | 1030/1715 | 1560/2395 | 1640/2510 | 3510 | 3950 | 4950 | ||
Shipping weight (kg) | 695/1370 | 755/1520 | 1349/1954 | 1130/1845 | 1690/2545 | 1770/2665 | 3730 | 4250 | 5245 | ||
STANDARDS | |||||||||||
Safety | IEC/EN62040-1;IEC/EN60950-1 | ||||||||||
Performance | IEC 62040-3 | ||||||||||
EMC | IEC/EN62040-2;IEC 61000-2-2;IEC61000-4-2;IEC61000-4-3;IEC61000-4-4; IEC61000-4-5;IEC61000-4-6;IEC61000-4-8;IEC 61000-4-11; |