High Quality Castle 80kVA High Frequency UPS

China High Quality Castle 80kVA High Frequency UPS, Find details about China 80kva Ups, High Frequency Ups from High Quality Castle 80kVA High Frequency UPS

Model NO.
EX80KS
Power Factor
0.8
Display
LCD
CE
Yes
ISO
Yes
Warranty
1 Year
Plug/Socket
Terminal Block
DC
384V
Trademark
MUST
Specification
CE/ISO
Origin
China
HS Code
8504402000
Model NO.
EX80KS
Power Factor
0.8
Display
LCD
CE
Yes
ISO
Yes
Warranty
1 Year
Plug/Socket
Terminal Block
DC
384V
Trademark
MUST
Specification
CE/ISO
Origin
China
HS Code
8504402000
Excellent performance in industrial environment protection
Just with the standard product, IP21 protection level (protecting the machine from the intrusion of solid material with the diameter larger than 12mm or the water drops) is achieved. If a higher protection level is required, the optional dust-proof accessories can help to increase the protection level in industrial environment and safeguard the UPS's security of operation in bad environment.
N+X parallel redundancy (compatible to battery share in the parallel mode)
The maximum of the inbuilt parallel mode is 8 UPS without any other external accessories, which helps the customer to extend the system capacity with low cost. N stands for the minimum amount of UPS in the load and X stands for the amount of redundant UPS in the system. The bigger the number of X is, the higher the reliability of the system.
The advanced controlling strategy is adopted to save the customer's investment by sharing a battery unit in the parallel redundancy mode.
Intelligent management of battery charging and discharging
The CUP- controlled advanced intelligent charging of battery enables the UPS's charger to rectify the charging parameter, and provide the optimum charging modes in the answer to the environment, types and amounts of cells, and the using condition of the battery. The scientific charging mode extends the battery's service lifetime. The optional addition to charging units shortens the time duration for the battery units recharging.
Frontal-board operation and maintenance
The full consideration of customer's efficiency in using the UPS is embodied in the module design and frontal-board maintenance, which saves time for repairing and improves the machine's usability.
Twin-channel line input
The UPS provides customer security in power supply with intelligent choice between two-line input or one-line input according to the actual condition.
High-efficient DSP chip
The digital Ti DSP controlling chip provides precise data processing capability with excellent performance in output and reliability.

Model
 

CASTLE EX 20KS
 

CASTLE EX 30KS
 

CASTLE EX 40KS
 

Rated Capacity
 

20KVA/16KW
 

30KVA/24KW
 

40KVA/32KW
 

Input
 

Voltage
 

210-475VAC
 

Frequency
 

40-70Hz

Self-adaptive to 50Hz and 60Hz
 

Phase Line
 

Three-phase 4 line + earth line
 

THDI
 

< 3 %
 

Input Power Factor
 

> 0.99
 

Twin-channel Line Input
 

Yes
 

Battery
 

Model
 

Valve-control lead-acid storage battery
 

Standby Time
 

Determined by the amount of external-connected cells
 

Output
 

 Voltage
 

220× ( 1±1 %) VAC
 

Frequency
 

50/60Hz
 

Phase line
 

Three-phase 4 line + earth line
 

Rated output power factor
 

8
 

Overload Capacity
 

125% 10min
 

 
 

150%  1min
 

Efficiency
 

Line Input Mode
 

93%
 

BAT Mode
 

93%
 

ECO Mode
 

98%
 

Intelligent Speed Control of Fan
 

yes
 

Display Device
 

LCD
 

I/O voltage, current, frequency, BAT voltage, charging current value, discharging current value, fault display, fault, warning
 

LED
 

The operation state of UPS
 

Warning Devices
 

Two ways of alerting: BUZZER sound, lamp signal,
 

CON Interface
 

RS232,AS400,RS485,Service,EPO, BAT temperature compensation, Intelligent Slot
 

Operation

Environment
 

Temperature
 

0-40C
 

 Humidity
 

10-99%
 

Weight
 

Net Weight
 

82Kg
 

90Kg
 

90Kg
 

Gross load
 

113Kg
 

130Kg
 

130Kg
 

Size W*D*H ( mm ) (host machine)
 

420×663.5×956
 

500×700×1150
 

500×700×1150