Liquid Temperature Controller Switch Refrigerator Electronic Hydraulic Capillary Thermostat

China Liquid Temperature Controller Switch Refrigerator Electronic Hydraulic Capillary Thermostat, Find details about China Capillary Thermostat, Hydraulic Capillary Thermostat from Liquid Temperature Controller Switch Refrigerator Electronic Hydraulic Capillary Thermostat

Model NO.
Type F/A2000
Capillary Length
180mm,Customized
G.W.
13.5 Kgs
Certificate
CE,CQC,RoHS
Application
Water Heater, Water Boiler, Electric Oven,
Temperature Range
-35c~ +320c
Temperature Differential
5% of Action Temperature
Material of Capillary and Sensing Bulb
Stainless Steel and Copper Optional
Diameter of Sensing Bulb
3mm, 4mm, 5mm, 6mm
Electric Rating
16(3)a 250VAC~10(1.8)a 400V
Material of Terminal
Brass
Mounting Hole
2-M4
Life Time
100000 Cycles
Trademark
JAYE
Transport Package
Carton and Wooden Box
Specification
Standard
Origin
China
HS Code
9032899090
Model NO.
Type F/A2000
Capillary Length
180mm,Customized
G.W.
13.5 Kgs
Certificate
CE,CQC,RoHS
Application
Water Heater, Water Boiler, Electric Oven,
Temperature Range
-35c~ +320c
Temperature Differential
5% of Action Temperature
Material of Capillary and Sensing Bulb
Stainless Steel and Copper Optional
Diameter of Sensing Bulb
3mm, 4mm, 5mm, 6mm
Electric Rating
16(3)a 250VAC~10(1.8)a 400V
Material of Terminal
Brass
Mounting Hole
2-M4
Life Time
100000 Cycles
Trademark
JAYE
Transport Package
Carton and Wooden Box
Specification
Standard
Origin
China
HS Code
9032899090
Liquid temperature controller switch Capillary Thermostat

When the temperature of the controlled object changes, the substance (generally liquid) in the temperature sensing part of the temperature controller will generate the corresponding physical phenomenon (volume change) of thermal expansion and cold contraction, and the capsule connected with the temperature sensing part will generate expansion or contraction. Based on the principle of lever, the on-off action of switch is driven to achieve the purpose of constant temperature. The liquid expansion temperature controller has the characteristics of accurate temperature control, stable and reliable, small temperature difference between start and stop, wide range of temperature control and adjustment, and large overload current.
Liquid Temperature Controller Switch Refrigerator Electronic Hydraulic Capillary Thermostat

Features:

1.Strictly comply with UL, CE, CQC, RoHS

2.Available in a wide temperature range and differential

3.Temperature adjustable through adjusting shaft

4.Auto-reset, manual-reset, and fixed temperature design available

5.Snap-Action electric switch

6.Little magnetic interference

7.Long life usage

8.Accessories, such as knob, bezel, capillary gland kit etc. available

9."D" shaped adjusting shafts with different lengths are available according to a variety of electrical appliance.


Technical Parameters:
ModelF2000 
CertificateCE 
Temperature range-35~`350 C 
Voltage250 V/AC 
Current16 A 
Differentialless than 3.5 C 
Capillary length180 mm 
IP protectionIP43 
Packaging50 pcs/CTN 
G.W.13.5 KGS 

Applicable to the refrigerator, freezer, showcase, central cooler and seafood pool and the other cooling equipment. Also applicable to dish-washing machine, washing machine, water heater and the other heating equipment. 
Designed temperature:-30~350ºC 
On-off temperature difference:2~12ºC 
Service temperature control range:-35~35ºC 0~40ºC 
Rated voltage and current:AC250V 16A 
The centres of installing hole:28mm with M4 screw

Liquid Temperature Controller Switch Refrigerator Electronic Hydraulic Capillary Thermostat

Precautions for use:
1. When the liquid expansion capillary temperature controller leaves the factory, the regulating shaft is at the high temperature point;
2. When installing the liquid expansion temperature controller, the temperature sensing package shall be as close to the surface of the controlled temperature object as possible, or the whole temperature sensing package and the temperature measuring medium shall have good heat conduction, which can reduce the temperature error and achieve the goal of accurate temperature control. During installation, the temperature sensing package shall not be deformed to avoid affecting its performance;
3. Corrosive liquid or conductive medium enters into the liquid expansion thermostat or pollutes the thermostat surface, so as not to affect the electrical insulation performance and product function;
4. When installing the hydraulic expansion thermostat, do not press the main body with the fastening screw. M4 * 5 or M4 * 6 is the appropriate fastening screw to avoid the main body deformation and the action temperature drift;
5. Capillary tube and temperature sensing bag are vulnerable parts, which shall not be bruised, flattened or broken. The main body and the junction between the temperature sensing cylinder and capillary tube shall not be twisted within 40mm. The bending radius of capillary tube shall be greater than 5mm. The capillary tube is hollow wire. Do not bend hard or at right angles to avoid blocking the flow of liquid inside. ;
6. The main body of the liquid expansion thermostat is sealed with red paint and fixed with nuts and screws, which are carried out after the temperature characteristic test and are not allowed to be adjusted at will. Otherwise, the performance of the thermostat will be changed;
7. The maximum allowable temperature of the temperature sensing package of the liquid expansion temperature controller: H / off (maximum temperature) + 30 ºC. If the temperature value is exceeded during use, the liquid expansion temperature controller will be damaged. When the temperature limiter is reset, it can only be reset manually when the temperature of the temperature sensing cylinder is reduced by more than 50 ºC;
8. The liquid expansion temperature controller should be handled with care to avoid damaging or affecting its performance.
9. When wiring, do not bend the terminal to avoid the change of internal spring clearance.
10. The input voltage and current shall not exceed the rated electrical specification of the product.
11. Do not press the temperature sensing rod hard to deform, so as to avoid internal pressure change and affect the accuracy.


Related Products:
Liquid Temperature Controller Switch Refrigerator Electronic Hydraulic Capillary Thermostat
Liquid Temperature Controller Switch Refrigerator Electronic Hydraulic Capillary Thermostat

Quality Control:
Liquid Temperature Controller Switch Refrigerator Electronic Hydraulic Capillary Thermostat

Transport and payment:
Liquid Temperature Controller Switch Refrigerator Electronic Hydraulic Capillary Thermostat