Low Frequency 60kVA 80kVA 100kVA Online UPS for 4 Hours Backup Time

China Low Frequency 60kVA 80kVA 100kVA Online UPS for 4 Hours Backup Time, Find details about China Low Frequency UPS, UPS from Low Frequency 60kVA 80kVA 100kVA Online UPS for 4 Hours Backup Time

Model NO.
GP33 series
Standby UPS
Sine Wave Output UPS
Output Capacity
Large Type
Equipment Mode
3 Phase UPS
Brand
Zlpower
Display
LCD
Transformer
Isolation Transformer
Technology
MCU Control, IGBT
Name
Low Frequency 3 Phase Online UPS
200kVA UPS
10kVA 3phase Online UPS
100kVA UPS
100kVA 3 Phase Online UPS
80kVA UPS
80kVA 3 Phase Online UPS
120kVA UPS
120kVA 3 Phase Online UPS
160kVA UPS
160kVA 3 Phase Online UPS
3 Phase Online UPS
3phase UPS for Date-Center
3 Phase UPS for ATM
3phase Online UPS for Industrial
Trademark
ZLPOWER
Transport Package
Wooden Pallet
Specification
CE, ISO9001
Origin
Shenzhen, China
HS Code
8504402000
Model NO.
GP33 series
Standby UPS
Sine Wave Output UPS
Output Capacity
Large Type
Equipment Mode
3 Phase UPS
Brand
Zlpower
Display
LCD
Transformer
Isolation Transformer
Technology
MCU Control, IGBT
Name
Low Frequency 3 Phase Online UPS
200kVA UPS
10kVA 3phase Online UPS
100kVA UPS
100kVA 3 Phase Online UPS
80kVA UPS
80kVA 3 Phase Online UPS
120kVA UPS
120kVA 3 Phase Online UPS
160kVA UPS
160kVA 3 Phase Online UPS
3 Phase Online UPS
3phase UPS for Date-Center
3 Phase UPS for ATM
3phase Online UPS for Industrial
Trademark
ZLPOWER
Transport Package
Wooden Pallet
Specification
CE, ISO9001
Origin
Shenzhen, China
HS Code
8504402000
Intelligent Low frequency online UPS 10KVA-200KVA, Three phase UPS
Pure sine wave low frequency UPS
High speed MCU, IGBT technology
Application: Goverment, Building, Large computer room, Lab, and so on
Low Frequency 60kVA 80kVA 100kVA Online UPS for 4 Hours Backup Time

Functions:
GP5300 series UPS is most advanced and new intelligent digital UPS by ZLPOWER. It is combined with high speed MCU, advanced CPLD technology, the sixth low consume large power, IGBT and static switch.
GP5300 series UPS have break the technology problems in stimulation circuit period. Digital control technology ensure that it can 100% apply to all kinds of grid environment, work with high stability. Each UPS capacity is from 10KVA to 400KVA, widely used in telecommunication, banks, negotiable securities, traffic, arms, security, electronics, industry, large enterprises and so on.
Low Frequency 60kVA 80kVA 100kVA Online UPS for 4 Hours Backup Time
Low Frequency 60kVA 80kVA 100kVA Online UPS for 4 Hours Backup Time
Low Frequency 60kVA 80kVA 100kVA Online UPS for 4 Hours Backup Time


Products features:
1. Advanced digital circuit system
2. Intelligent management of batteries status
3. Intelligent inspect and monitor UPS systems every second
4. Intelligent communication tool remote control
5. The sixth generation IGBT inverter technology
6. High definition screen information management technology, humanity LCD display with Chinese and English, can show directly UPS status and operation, data records in table format, and events records, also can change language by main menu.
7. LED status shows operate steps and status directly.
8. GP5300 series UPS use touch screen with excellent ageing resistance function and case dealed with fluorin and carbon technology, lead it is environmental and durable; The UPS adopts knock-down modular design, ensure it easy to maintain and save resources much; It is with new advanced turbofan which can release heat well and save energy; It also use non-circumfluence controlled circuit, can save electric much; GP5300 UPS adopts green commute and inverter technology, ensure to provide clear energy for users; Its advanced digital circuit technology let whole UPS with 80% more life than before.
9. Excellent load characters can fulfill with suddenly change load from 0 to 100%, and no need to invert to bypass, ensure output stable and reliable.
10. Well-equipped protection function, including alarm function and excellent input and output Undervoltage overflow protection, input surge protection, phase failure protection, battery overcharge and over discharge protection, output overload short circuit protection, over heat protection and so on.
11. High quality active features, adopts instantaneous control method and virtual value response control and so on. This function realizes high active adjust and decrease output voltage degree of distortion.
12. Three phase can equal stable voltage and control separately, in order to control instantaneous overload degree of equal, realize output imbalance 100% load.
13. Optional input harmonic filter or Twelve-pulse rectifier, can restrain input harmonic pollution efficiently, improve UPS input power factor, and minish input harmonic current.
14. Optional battery inspection module, can test specification of every battery, and show on display. If battery faulty, will alarm immediately and notice administrators.
15. Special set: Can set UPS work status according to requirements of electric. User can choose from UPS operate mode, ECO save energy operate mode and EPS operate mode.
ModelGP3310 ~ GP33200 series UPS
Capacity (VA)10K15K20K30K40K60K80K100K120K160K200K
Noninal output capacity8KW12KW16KW24KW32KW48KW64KW80KW96KW128KW160KW
Operate typeDouble conversion online type
Inputvoltage220V/380, 230/400, 240/415V, ±25%
PhaseThree phase +N+G
Frequency50Hz/60Hz±5%
Input power factor0.95(with input filter)
Soft start0-100% 5sec
OutputVoltage220V/380, 230/400, 240/415V, ±1% (stable load), ±5%(active load)
PhaseThree phase +N+G
Frequency50/60Hz (1±5%, AC mode), 50/60Hz (±1%, Battery mode)
Power factor0.8
Output wavePure sine wave
DistortionLinear load <3%, non linear load<5%
Battery voltageStandard battery voltage360V/384V
Floating charge405V/432V
Terminal voltage315V/336V
Charge current1A-50A (Can calculate and set according to battery configuration software)
Maximum discharge current28425685113169225282338381507
Main FunctionActive voltage change0-100%±5%
Instant recover time<10ms
Imbalance voltage<±5%,<±1%( Balance load voltage)
Overload capacity125%→10min,150%→1min
Static switchAutomatic
ProtectionUPS over current, short circuit, battery low voltage, over heat
Cold methodCompel aeration ( temperature control mode)
Noise60-65dB
DisplayLED; LCD display
Communication port(Optional)RS232, SNMP, dry-contact
AlarmAlarm with buzzer and indicators
EnvironmentTemperature: 0-40C  Humidity: 0-90%
Low Frequency 60kVA 80kVA 100kVA Online UPS for 4 Hours Backup Time