China Roll Over Image to Zoom In12V Power Supply 60A 30A 120W 400W DC Universal Regulated Switching for CCTV, Radio, Computer Project, LED Strip Lights, 3D Printer, Find details about China UPS Function, Charger for CCTV from Roll Over Image to Zoom In12V Power Supply 60A 30A 120W 400W DC Universal Regulated Switching for CCTV, Radio, Computer Project, LED Strip Lights, 3D Printer
Roll over image to zoom in12V Power Supply 60A 30A 120W 400W DC Universal Regulated Switching for CCTV, Radio, Computer Project, LED Strip Lights, 3D Printer
S-400W series normal single switching power supply
Features:
·AC input voltage range selected by switch
·Small volume,low weight,high efficiency
·Protections:short circuit/over load/over voltage/over temp
·Built-in cooling DC fan
·Cooling fan ON-OFF auto control
·LED indicator for power on
·100% full load burn-in test
·2 Years warranty
Model | S-400-5 | S-400-12 | S-400-15 | S-400-24 | S-400-36 | S-400-48 | |
output | DC voltage | 5V | 12V | 15V | 24V | 36V | 48V |
Voltage tolerance | ±2% | ±1% | ±1% | ±1% | ±1% | ±1% | |
Rated current | 60A | 33A | 27A | 16.5A | 11A | 8.3A | |
Current range | 0~60A | 0~33A | 0~27A | 0~16.5A | 0~11A | 0~8.3A | |
Rated power | 300W | 396W | 405W | 396W | 396W | 398.4W | |
Ripple&noise | 100mvp-p | 150mvp-p | 150mvp-p | 150mvp-p | 180mvp-p | 200mvp-p | |
DCvoltage ADJ.range | -9%~+10% | ±10% | ±10% | ±10% | ±10% | ±10% | |
input | Voltage range | 90~132VAC/180~264VAC(selected by switch),255~373VDC | |||||
frequency | 47~63HZ | ||||||
AC current | 7.5A/115VAC,4.5A/230VAC | ||||||
efficiency | 78% | 80% | 80% | 82% | 82% | 83% | |
Inrush current | Cold start current30A/115VAC,60A/230VAC | ||||||
Leakage current | < 3.5mA/240VAC | ||||||
protection | overload | Rated output power105%~135% start over load protection | |||||
protection type :rated current limit,auto-recovery after fault condition is removed | |||||||
Over voltage | 6.8~8.2V | 15.6~17.8V | 18.6~20.8V | 30.6~33.2V | 42.6~44.2V | 54.8~56.6V | |
Protection type:hiccup mode,auto-recovery after fault condition is removed | |||||||
Over temperature | ≥55ºCfan on,≤50ºCfan off,≥85ºCstart over temperature protection | ||||||
Protection mode:cutoff output,auto-recovery after temperature become normal | |||||||
environment | Working temp,humidity | -10ºC~+60ºC,20%~90%RH | |||||
Storagetemp,humidity | -20ºC~+85ºC,10%~95%RH non-condensing | ||||||
Withstand vibration | 10~500HZ,2G10min/1cycle,period for 60 minutes,each axes | ||||||
safety | Withstand voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||
Isolation resistance | I/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC | ||||||
Fitstandard | Safety standard | Compliance to UL1012 | |||||
EMC standard | Compliance to EN55022,CLASSA | ||||||
others | Dimension | 215*115*50mm(L*W*H) | |||||
Weight/packing | 1.0kg/24pcs/25kg/0.049 m³/1.72CUFT | ||||||
note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and25ºCof ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |