China Automatic Rubber Environment UV Weathering Aging Testing Chamber, Find details about China UV Aging Testing Chamber, Rubber Aging Testing Chamber from Automatic Rubber Environment UV Weathering Aging Testing Chamber
Studio size (W×D×H) | 1140mm×400 mm×500 mm |
Overall size (W×D×H) | 1340mm×530 mm×1400 mm |
Center distance of the lamp | 70mm |
Distance between the specimen and the nearest parallel surface of the lamp surface | about 50mm±2mm |
Wavelength range | UVA wavelength range of 315 to 400nm, the peak at about 340nm |
Radiation intensity | within 1W/m2/340nm |
Temperature resolution | 0.1ºC |
Light temperature range | 50ºC~70ºC / temperature tolerance is ±3ºC |
Condensation temperature range | 40ºC~60ºC / temperature tolerance of ±3ºC |
Measuring range of blackboard thermometer | 30~80ºC / tolerance is ±1ºC |
Temperature control mode | PID self - tuning temperature control mode |
Humidity range | about 45%~70% R.H. |
Water tank requirements | water depth not more than 50mm, and with an automatic water supply controller |
Standard specimen size | 75×150mm 48pcs |
Recommended operating environment | 5~35ºC, 40%~85%R•H, 300mm away from the wall |
Voltage | 220V±5%, single-phase three-wire, 50Hz, 10A, required 15A leakage switch |
Lamp selection | domestic Huaqiang lamp/American Atlecs lamp |
Protection system | Overload short circuit protection Over temperature protection Water lacking protection Earth leakage protection Auto shut off protection |