Large Capacity Electrical Auto Control Door Pulse Vacuum Steam Autoclave

China Large Capacity Electrical Auto Control Door Pulse Vacuum Steam Autoclave, Find details about China Autoclave, Sterilizer from Large Capacity Electrical Auto Control Door Pulse Vacuum Steam Autoclave

Model NO.
HP-AC360SD
Sterilization Information Recording and Printing
Sterilization Information Recording and Printing
Material
Stainless Steel
Designing Pressure
-0.1 to 0.26MPa
Rated Working Pressure
0.242MPa
Max Temperature
140degree
Pulse Vacuum Times
0 to 99times
Drying Time
0 to 9999s
Steam Pressure
0.30MPa to 0.50MPa
External Size
307X1236X1780mm
Chamber Size
1000X600X600mm
Trademark
HEPOBIO
Transport Package
Export Packing
Specification
360L
Origin
Henan Province
HS Code
8419200000
Model NO.
HP-AC360SD
Sterilization Information Recording and Printing
Sterilization Information Recording and Printing
Material
Stainless Steel
Designing Pressure
-0.1 to 0.26MPa
Rated Working Pressure
0.242MPa
Max Temperature
140degree
Pulse Vacuum Times
0 to 99times
Drying Time
0 to 9999s
Steam Pressure
0.30MPa to 0.50MPa
External Size
307X1236X1780mm
Chamber Size
1000X600X600mm
Trademark
HEPOBIO
Transport Package
Export Packing
Specification
360L
Origin
Henan Province
HS Code
8419200000
PRODUCT CHARACTERISTICS:
1,The inner chamber is made of S30408, the jacket is made of pressure vessel special steel plate. The manufacture adopts advanced welding technology and detection means to ensure reliable and durable of the autoclave;
2,The whole process of sterilization adopts microcomputer control, high degree of automation, color touch screen dynamically displays operating temperature,pressure, time, sterilization stage and other parameters, the operation is more intuitive and convenient;
3,Equipped with several sets of sterilization procedure (fabric, instruments, liquid,etc.), operational parameters also can be set according to the actual situation of the user;
  Vacuum test and BD test program, vacuum leak rate is less than 0.13Kpa/min;
4,The safety interlock device meets the requirements of there regulations;
(1) Sterilization program cannot be started if the door is not closed and locked;
(2) When pressure in chamber, the door can not be opened;
5,Air compression type seal ring which has good sealing effect and long service life;
6,PID temperature control function, select it to correct heating control parameters automatically, to prevent the temperature overshoot occurs;
Notes:
The self-produced steam autoclave is equipped with steam generator and water pump, the functions are as follows:
(1) The water pump has the automatic add water function, so that the water level in the steam generator can be controlled in a reasonable range;
(2) When the water level in the steam generator reaches the minimum, the electric power supply will be cut off with the alarm;
(3) The pressure controller to control the pressure in the steam generator, a safety valve for overpressure protection;


TECHNICAL PARAMETERS:
Model
(manually operated door)
Chamber  Size
(mm)
Volume
(M3)
Power
Supply
Power
(KW)
Overall  Size
(L×D×H) mm
Steam
Source
HP-AC240S 671×600×6000.24380V/50HZ24927×1236×1780
 single leaf door
built-in
 HP-AC240SD  1.95927×1236×1780
 single leaf door
external
1.95977×1236×1780
 two leafs door
external
HP-AC360S   1000×600×6000.36241260×1240×1790
 single leaf door
built-in
HP-AC360SD  1.951257×1236×1780
 single leaf door
external
1.951307×1236×1780
 two leafs door
external
HP-AC600S  1200×610×9100.6241443×1281×1910
 single leaf door
built-in
HP-AC600SD2.851443×1281×1910
 single leaf door
external
2.851492×1281×1910
 two leafs door
external
    HP-AC1200SD1500×750×10801.24.351797×1386×1931
 single leaf door
external
4.351861×1386×1931
 two leafs door
external
HP-AC2500SD2100×1000×12002.54.52435×1793×1991
 single leaf door
external
4.52510×1793×1991
 two leafs door
external

Standard Sets:Transfer carriage(single for single leaf door,double for double leaft door),Sterilizer loading cart.