Item | Specification |
Capacity | 72,000 Litre per Day (19022GPD) |
Salt Rejection Rate | ≥ 99.5% |
Feed Water TDS | ≤ 36000 PPM |
Inlet Temperature | 5~45ºC |
Production water TDS | <700PPM |
Operating | Automation and Manual |
Voltage | 380V/three-phase/50HZ (can be customized) |
System power | 18.5 KW |
RO Type | 1 stage RO |
RO membrane | USA DOW(Optional) |
Recovery rate | 40% |
Operation Pressure | <6.5Mpa |
Net Weight | 2100 KG |
Dimension(L*W*H) | 20 feet container |
Usage | Drinking Water, Industrial Process Water Treatment |
Certification | ISO9001,CCS |
Warranty | 2 years |
Feed pump: Single water flow: 9m3/h Head of delivery: 50m Power: 2.2KW | Brand name: GRUNDFOS(Optional) Providing backwashing and rinsing engine for multi medium filter and precision filter. |
Multi medium filters: Dimension:Ø750x1900mm, FRP Single water output: >10m3/hr Output pressure: 0.4Mpa | The function of multimedia filter is to guarantee all the alga, specially the suspended solid, minerals, metals and and many other large particulate get rid of the original water .The filter can reduce the pollution index of the original water which can meet the RO system's requirement at a long term. This multimedia filter has installed rinse system , which will rinse and backwash the filter manual and periodically ,this measure guarantees the quality of the inlet water without worrying the filter will be blocked up by the pollution particulate. |
Precision Filter: 12m3/h,5μm,UPVC | The inner part of UPVC micro filtration filter is set 10um winding wire filter cartridge and 5umpp filter cartridge. In order to prevent the material leakage in filter and left suspended solid from entering the membrane system before water enter reverse osmosis equipment through passing activated carbon filter, a security filter should be set ahead of the membrane system. Taking account of the filtering effect, operation cost and convenience to replace the filter bag and other operation, this design adopts the most advanced filtration technology of our company. |
High pressure pump: | Brand name: GRUNDFOS(Optional) The effect of high pressure pump is to provide enough input pressure for reverse osmosis device. According to the nature of reverse osmosis itself, a certain degree of driving force is needed to overcome osmotic pressure and other resistance and to reach the specific productivity designed. |
Reverse osmosis system: | RO membrane: DOW (Optional) RO system is the central desalination unit in this system, almost all soluble salt, colloid, organics and microbe will be cleaned out by applying the RO membrane's peculiarity. The qualified output water by pretreatment enter RO system. Water molecule throw membrane, collect by plumbing, finally, enter water tank. Concentrate water be collected by another plumbing, finally, it is exhausted. the system have valves, monitoring meter and programming controller operating system, they will ensure systematic running chronically. |
Rinse system: | Ro system after running chronically, It can be polluted by some substances rinse out hardly. Micro-salt and organics scale chronically to make film performance decline, operating pressure go up, so system must be rinse with chemical agent, so that it return to normal. |
Site online monitoring instruments: | In order to monitor the normal operating and realize automatic operation under certain conditions, we has equipped with site online monitoring and control instruments in the system, which includes:Pressure Switch,Safety Valve,RO output conductivity meter,Output Rota meter. |
Device Framework: | The framework is made of industry-standard thick-walled stainless steel tube, and pipe outer surface is polished. |
Control system: | Basic control system: The basic components of Electrical control system adopt Schneider's components, with high-pressure pump and output pump of PLC control module control system. On-site control cabinet: Equipment operating interface has on-site control cabinet, which is made of color steel spray. |