China High Quality Switching Power Supply Offgrid Tie AVR Inverter, Find details about China Low Frequency Inverter, Pure Sine Wave Inverter from High Quality Switching Power Supply Offgrid Tie AVR Inverter
Model Parameters | GW1000 | GW2000 | GW3000 | GW4000 | GW5000 | GW6000 | |
AC Input | Nominal Power | 1000W | 2000W | 3000W | 4000W | 5000W | 6000W |
Input Voltage Waveform | Sinusoidal (utility or generator) | ||||||
Nominal input Voltage | 120VAC/230VAC | 230VAC | |||||
Input Voltage Range | 80Vac-150Vac for 120V, 135Vac-270Vac for 230V | ||||||
Low Line AVR Disconnect | 100Vac±4% for 120V, 195Vac±4% for 230V | ||||||
Low Line AVR Re-connect | 95Vac±4% for 120V, 185Vac±4% for 230V | ||||||
Low Line Disconnect | Normal:85Vac±4%,Wide:80Vac±4% for 120V, Normal:154Vac±4%,Wide:135Vac±4% for 230V | ||||||
Low Line Re-connect | Normal:90Vac±4%,Wide:85Vac±4% for 120V, Normal:164Vac±4%,Wide:145Vac±4% for 230V | ||||||
High Line Disconnect | Normal:136Vac±4%,Wide:140Vac±4% for 120V, Normal:263Vac±4%,Wide:263Vac±4%for 230V | ||||||
High Line Re-connect | Normal:131Vac±4%,Wide:135Vac±4% for 120V, Normal:253Vac±4%,Wide:253Vac±4%for 230V | ||||||
Max AC input Voltage | 120V for Max150V, 230V for Max270V | ||||||
Frequency | 50Hz:41-54Hz, 60Hz:51-64Hz | ||||||
AC output | Output Voltage Waveform | Sine wave | |||||
Power Factor | 0.9~1.0 | ||||||
Nominal Output Voltage (V) | LV:120Vac ±10%rms, HV:230Vac ±10%rms | ||||||
Nominal Output Frequency (Hz) | 50Hz ± 0.3Hz, 60Hz ± 0.3Hz | ||||||
AC Charger | Nominal Charger Current | 20A/35A/50A/70A/90A(5 stages adjustable charging current) | |||||
Over charge Protection | Bat.V≥15.5VDC for 12V battery, Bat.V≥31.0VDC for 24V battery, Bat.V≥62.0VDC for 48V battery, beeps 0.5s every 1s & fault after 60s | ||||||
Efficiency | Efficiency (Battery Mode) | ≥85% | |||||
Efficiency (Line Mode) | >98% | ||||||
Battery Voltage | Nominal DC input Voltage | 12/24/48Vdc | 24/48Vdc | ||||
Low Battery Alarm | 10.5VDC±0.3VDC for 12Vdc | ||||||
21VDC±0.6VDC for 24Vdc | |||||||
42VDC±1.2VDC for 48Vdc | |||||||
High DC input Alarm & Fault | 16VDC±0.3VDC for 12Vdc | ||||||
32VDC±0.6VDC for 24Vdc | |||||||
64VDC±1.2VDC for 48Vdc | |||||||
Transfer Time | 15ms(max) | ||||||
System Parameter | Over-Load Protection | 110%the output,load>150%,beeps 0.5s every 1s,and Fault after 20s | |||||
Output Short Circuit Protection | Current limit (Fault after 10s) | ||||||
Surge Rating(10s) | 1:3(VA) | ||||||
Protections | Low battery,over charging,over load,over temp | ||||||
Indicators | LED+LCD Display | ||||||
General Specifications | Operating Temperature Range | 0ºC~40ºC | |||||
Storage Temperature | -15ºC~60ºC | ||||||
Operation humidity | 5% to 95%(non-condensing) | ||||||
Audible Noise | 60dB max | ||||||
cooling | Forced air,variable speed fan | ||||||
Dimension(L*W*H) | 475*242*182 | 653*242*185 | |||||
Net Weight(kg) | 17.1 | 19.3 | 22.5 | 34.5 | 37.6 | 38.8 |