Generals for non clogging multistage fan waste water treatment pump :
QDG series Multistage high pressure centrifugal pump small flow high head is multi-stages centrifugal pump. It used for boiler water feed or other industry hot water supply projects.
QDG series hot water pump matches the performance, technical requirement and testing method for the international boiler projects.
This series centrifugal pump small flow high head meet the international standard, with the feature of small volume, good performance, stable and reliable operation, and high efficiency. Besides, it is the best choice for the hot water supply projects.
hot water pump included horizontal boiler feed water pump and vertical boiler feed water pump.
QDG series centrifugal pump small flow high head is multi-stages centrifugal pump. It used for boiler water feed or other industry hot water supply projects.
QDG series hot water centrifugal pump matches the performance, technical requirement and testing method for the international boiler projects.
This seriescentrifugal pump small flow high head meet the international standard, with the feature of small volume, good performance, stable and reliable operation, and high efficiency. Besides, it is the best choice for the hot water supply projects.
It included horizontal centrifugal pump small flow high head and vertical centrifugal pump small flow high head.
Pump Performance Range
non clogging multistage fan waste water treatment pump
Flow rate: 3~500m3/h
Head: 70~650m
Pressure: 7~65Bar
Speed: 1450~2950rpm
Max Eff: 90%
Application for non clogging multistage fan waste water treatment pump
Aerospace Oil & Gas
Building industry Power Station
Chemical Petro-Chemical
General Industry Pharmaceutical
Marine Pulp & Paper
Mining & Aggregate Water & Waste water
Advantages about non clogging multistage fan waste water treatment pump :
20 years in producing centrifugal pump small flow high head
Independent Design
advanced technology from Australia, Canada, America
Specialized Test Equipment
Anti-rust treatment casting
Supply reasonable suggestion for choosing pumps
OEM available
Performance Data Sheet for non clogging multistage fan waste water treatment pump :
Pump Type | Flow (m3/h) | Head (m) | Power (KW) | Speed (r/min) |
QDG 6-25 | 3.75-7.5 | 73.5-306 | 4-11 | 2950 |
QDG 12-25 | 7.5-15 | 69-338.4 | 5.5-22 | 2950 |
QDG 12-50 | 7.5-15 | 139.5-648 | 18.5-75 | 2950 |
QDG 25-30 | 15-30 | 82.5-340 | 15-45 | 2950 |
QDG 25-50 | 15-30 | 15.78-618 | 22-110 | 2950 |
QDG 46-30 | 30-55 | 81-340 | 22-75 | 2950 |
QDG 46-50 | 30-55 | 138-666 | 37-132 | 2950 |
QDG 85-45 | 55-100 | 78-459 | 37-160 | 2950 |
QDG 85-67 | 55-100 | 183-666 | 90-250 | 2950 |
QDG155-67 | 100-185 | 177-684 | 132-400 | 2950 |
QDG280-43 | 185-335 | 114-423 | 160-450 | 1480 |
QDG280-65 | 185-355 | 372-680 | 500-800 | 1480 |
QDG450-60 | 335-500 | 171-650 | 360-1050 | 680 |
RFQ:
Tips for non clogging multistage fan waste water treatment pumpmp installation
Please take note as below when install the high pressure water pump:
1. The preformed hole on the foundation should be poured as the pump installation drawing.
2. The installation level should meet the demand of the allowed vacuum suction height. The foundation should be in horizontal and stable condition, to make sure the rotation of the driver machinery same with the pump in the direction.
3. When connect by coupling, must make sure the pump and driver shaft center should be in a straight line.
4. If belt connection, the shaft center should be in parallel.
5. The boiler feed water pump suction pipe should be sealed well, and try to less the quantity of the elbow and check valve. When fill water, exhausted the air. It should be no any air when operate. We need to keep the suction pipe slopes up slightly, and then connect with the pump inlet.
QA&QC
Reliable and comprehensive quality assurance system ensures the excellent quality of our products. We have got the "International Standard" certification, manufactured according to GB, Department of superscript, and industry standards, we implement a comprehensive quality management during the entire process of production, accordance with the process file processing strictly, and a variety of detection methods etc.
We have meet the requirements of GB3216-89 national Class B accuracy, <>, computer test data monitoring of water test pumping station application. There are physical chemistry laboratory, metallographic analysis room in our factory, for testing material properties in different respects.
1. Quality Policy
Advocates quality is the life of enterprise, assiduous, the pursuit of excellence
2. Quality objectives
qualified products rate 99%, factory qualified pass rate: 100%
3. Quality Commitment
1) We will continue to improve the awareness of quality, implementing as GB/T19001-2000 quality assurance model standard, meeting technical requirements stipulated in the contract. We are not only discharge for the supplier host, but also for the quality of spare parts, external assistance products etc.
2) We promise the delivery time stipulated in the contract.
An Pump Machinery information
Contact
Sherry Lee
Shijiazhuang An Pump Machinery Co.,Ltd
anpump.en.made-in-china.com
Tel:86-311-89940549 Fax:86-311-86271170