En50288-2-2/ IEC 61156-5 Guideline Signalling System Cables for Industrial Manufacturing

China En50288-2-2/ IEC 61156-5 Guideline Signalling System Cables for Industrial Manufacturing, Find details about China Ethernet Cable, Communication Cable from En50288-2-2/ IEC 61156-5 Guideline Signalling System Cables for Industrial Manufacturing

Model NO.
PROFINET 4x22AWG
Material Shape
Round Wire
Range of Application
Flame Retardant
Certification
ISO9001, China Railway Inspection and Certification Center
Cable Structure
Star
Insulation Diameter
1.50mm
Filling Material
PE
Shield Material
Aluminium Foil
Shield Coverage
Min.90%
Casing Diameter
6.60mm
Casing Thickness
1.10mm
Working Temperature
-40 ~ +90ºC
Usage
Industrial Manufacturing, Automation Process, etc.
Color
Black or Customized
Guideline
En50288-2-2, IEC 61156-5
MOQ
100 Meters
Trademark
METALLURGICA BRESCIANA
Transport Package
Drum/Bobbin/Coil
Specification
70kg/km
Origin
Anhui, China
Model NO.
PROFINET 4x22AWG
Material Shape
Round Wire
Range of Application
Flame Retardant
Certification
ISO9001, China Railway Inspection and Certification Center
Cable Structure
Star
Insulation Diameter
1.50mm
Filling Material
PE
Shield Material
Aluminium Foil
Shield Coverage
Min.90%
Casing Diameter
6.60mm
Casing Thickness
1.10mm
Working Temperature
-40 ~ +90ºC
Usage
Industrial Manufacturing, Automation Process, etc.
Color
Black or Customized
Guideline
En50288-2-2, IEC 61156-5
MOQ
100 Meters
Trademark
METALLURGICA BRESCIANA
Transport Package
Drum/Bobbin/Coil
Specification
70kg/km
Origin
Anhui, China
Product Description

Ethernet CAT5E cable offers high-speed data transmission.It is resistant to abrasions and cuts, while also has an excellent resistance to oil and chemicals. Dedicated bus cables widely used in industrial manufacturing, automation process, communication field.

Ethernet CAT5E Cable Structure/Size
ConductorNumber of wires x diameter19x0.153mm
MaterialTinned copper wire
TypeConforms to IEC 60228 category 6 conductor
Dielectric (insulation)Diameter1.50mm
MaterialFoamed polyethylene
FillingMaterialPolyethylene
CableStructureStar
ShieldMaterialAluminium foil
Coverage (weaving density)Min.90%
Casing (sheath)MaterialsCross-linked polyolefin (EN50264-1 EM104)
ColorBlack or Customized
Diameter6.60mm
Thickness1.10mm
Mechanical Physical Properties
Working temperature range-40 ~ +90ºC
Operating voltage300V
Weight70kg/km
Minimum bending radius (fixed)40mm
Sheath tensile strenght≥10MPa
Sheath elongation≥125%
Sheath aging conditions120x240ºCxh
Change rate of sheath tensile strength≤30%
Sheath elongation resistance rate of change≤30%
Sheath thermal extension test conditions200x15ºCxmin
Thermal extension test mechanical stress20N/cm2
Elongation rate under load in hot extension test≤100%
Hot elongation test elongation rate when unloading≤25%
Low Frequency Electrical Performance 
Maximum conductor DC resistance (20ºC)54.4Ω/km
Minimum insulation resistance (20ºC)5000MΩ·km
Core/core capacitanceNominal: ≤50pF/m (1kHz)
Core/screen capacitanceNominal: ≤100pF/100m (1kHz)
Unbalanced core/screen capacitanceNominal: ≤1.5pF/m (1kHz)
Withstand voltage test core/coreAC 1.5kV (1min)
Core/screenAC 1.5kV (1min)
Surface transfer impedance1MHz:≤10MΩ/m, 10MHz:≤10MΩ/m, 30MHz:≤30MΩ/m, 100MHz:≤100MΩ/m
High frequency electrical performance
Characteristic impedance (Z0)100±5Ω (0.75~3MHz)
Attenuation (ATT)Compliant with EN 50288-2-2
Return loss (RL)Compliant with IEC61156-5
Near-end crosstalk (NEXT)Compliant with EN 50288-2-2
Near-end crosstalk power sum (PSNEXT)Compliant with IEC61156-5
Equal level far-end crosstalk (ACR-F)Compliant with EN 50288-2-2
Equal level far-end crosstalk power sum (PSACR-F)Compliant with IEC61156-5
Delay (PD)Compliant with IEC61156-5
En50288-2-2/ IEC 61156-5 Guideline Signalling System Cables for Industrial Manufacturing

 

Features

We are dedicated to the use of non-toxic insulation materials that are halogen free, have lower gas emission and smoke opacity and prevent flame spreading in case of fire.
En50288-2-2/ IEC 61156-5 Guideline Signalling System Cables for Industrial Manufacturing

En50288-2-2/ IEC 61156-5 Guideline Signalling System Cables for Industrial Manufacturing
Production Line

 

En50288-2-2/ IEC 61156-5 Guideline Signalling System Cables for Industrial Manufacturing
1. The production cycle begins with the processing plated copper wires, which are then processed through stranding machineries to obtain different copper wire diameters.
2. The production process continues with the primary insulation and stranding phase of the semi-finished product. This semi-finished product builds the base for further stages of our production.
3. In the following steps, through the most modern equipment, shielding and taping operations are carried out (mainly dedicated to special cables).
4. The last production cycle involves the secondary insulation phase or the final coating in insulating material of the product obtained with a sheath in specific plastic materials according to the type of cable under production.

All production steps involve the use of innovative techniques for process control, in order to ensure compliance with the different types of cables. The production range covers many sectors, from railways, optical, telecommunications, oil&gas, industrial automation to marine industry, as result of continuous investments in research and development.
En50288-2-2/ IEC 61156-5 Guideline Signalling System Cables for Industrial Manufacturing

Our Advantages

The production process is completed by a state-of-the-art laboratory for tests and inspections, which allows us to continuously monitor the compliance of the products with the technical and regulatory specifications. The laboratory is operated by highly skilled technicians, has the latest test equipment and performs 100% of the characterization on raw materials and normative tests on the finished products.

Our products have been designed and engineered in Italy, and our Chinese production reflects and improves on that know-how.
En50288-2-2/ IEC 61156-5 Guideline Signalling System Cables for Industrial Manufacturing

Company Profile

En50288-2-2/ IEC 61156-5 Guideline Signalling System Cables for Industrial Manufacturing
Metallurgica Bresciana S.p.A.vwas founded in 1968 starting with the production of copper multi-tubes for instrumentation in the Oil & Gas sector.

In the early 90's, Metallurgica Bresciana see the broadband business opportunity and decide to invest in the newest machinery for the production of fiber optic cables.

In 1993, as a result of a large investment, the construction of the first and only linear electron beam accelerator in Italy became a fact. E-beam irradiation is a process in which the polymer is exposed to a high charge stream of electrons which improves the mechanical and physical properties of the insulating material. This helped with the development of cables for the railway sector, such as internal cabling for rolling stock and miniaturized high temperature resistant cables for railway and industrial applications.  
 

In 2011 Metallurgica Bresciana S.p.A. expand its international activities by establishing a new production site in Ma'anshan, China for the production of cables for the local market.

En50288-2-2/ IEC 61156-5 Guideline Signalling System Cables for Industrial Manufacturing
En50288-2-2/ IEC 61156-5 Guideline Signalling System Cables for Industrial Manufacturing
En50288-2-2/ IEC 61156-5 Guideline Signalling System Cables for Industrial Manufacturing
Our Customers

The quality of cables we are making are the key factor for the safety of mass transportation. We are dedicated to the satisfaction and success of every customer.
En50288-2-2/ IEC 61156-5 Guideline Signalling System Cables for Industrial Manufacturing

Certifications

En50288-2-2/ IEC 61156-5 Guideline Signalling System Cables for Industrial Manufacturing

FAQ

Q1: Are you the real factory?
A:Yes, we are one of the production plant of our international company.

Q2: What is your main products?

A:Cables for different industries and uses. We offer customized solutions.

Q3: What is your delivery time? 
A: Withing 15 days for about 30km of standard product. Time is variable for special solutions.

Q4: MOQ: what is your minimum quantity?
A: 300 meters.

Q5: Package & Shipping & Delivery

A: For large orders:  customized.