ISO 4589-2 Limited Oxygen Index Tester Lab Testing Equipment

China ISO 4589-2 Limited Oxygen Index Tester Lab Testing Equipment, Find details about China Oxygen Index Tester, Limited Oxygen Index Tester from ISO 4589-2 Limited Oxygen Index Tester Lab Testing Equipment

Model NO.
GD-ISO4589
Overseas Training
Provide
Model
Auto. and Manual
Type
Fire Testing Equipment
Warranty
12months
Oxygen Concentration Measurement Range
0~100%
Oxygen Sensor Response Time
<2s
Oxygen Concentration in Accuracy
+- 0.1%
Pressure Meter Accuracy
+- 0.1%
Working Pressure
0.1MPa
Trademark
GOLD
Transport Package
Standard Export Wooden Case
Specification
435mm(W)*550mm(D)*670mm(H)
Origin
Chongqing China(Mainland)
HS Code
9031809090
Model NO.
GD-ISO4589
Overseas Training
Provide
Model
Auto. and Manual
Type
Fire Testing Equipment
Warranty
12months
Oxygen Concentration Measurement Range
0~100%
Oxygen Sensor Response Time
<2s
Oxygen Concentration in Accuracy
+- 0.1%
Pressure Meter Accuracy
+- 0.1%
Working Pressure
0.1MPa
Trademark
GOLD
Transport Package
Standard Export Wooden Case
Specification
435mm(W)*550mm(D)*670mm(H)
Origin
Chongqing China(Mainland)
HS Code
9031809090
ISO 4589-2 Limited Oxygen Index Tester Lab Testing Equipment

ISO 4589-2 Limited Oxygen Index Tester Lab Testing Equipment

Introduction:
ISO 4589-2 ASTM D2863 Limited Oxygen Indix Tester is designed and made according to ISO 4589-2, it applies to analysis the minimum oxygen concentration needed to maintain combustion of the sample when the sample is under the test conditions specified in oxygen and nitrogen mixed gas.

ISO 4589-2 ASTM D2863 Limited Oxygen Indix Tester is installed with England import Oxygen sensor, automatic control the Oxygen and nitrogen flow with mass flow control meter. It is very easy and quick to operate. Used from evaluating homogeneity of solid materials, laminates, foam, film and thin film in the specified conditions of flammability. 


Application:
Building Materials
Wire & Cable
Upholstered Furniture
Other


International standards:
ASTM D 2863Standard Test Method for Measuring the Minimum Oxygen Concentration to Support Candle-Like Combustion of Plastics (Oxygen Index)
ISO 4589-2Plastics - Determination of burning behaviour by oxygen index - Part 2: Ambient- temperature test
ISO 4589-3Plastics - Determination of burning behaviour by oxygen index - Part 3: Elevated-temperature test
NES 714 
NES 715 
 
Product Image:
ISO 4589-2 Limited Oxygen Index Tester Lab Testing Equipment


Features:
  1. Paramagnetic Cell to measure exact oxygen concentration. 
  2. Auto & Manual mode (Select control and analysis by personal computer or user). 
  3. Automatic Mass Flow Controller. 
  4. Precision display window on the software to facilitate easy reading of oxygen concentrations. 
  5. Specimen Holder facilitating separation and attachment of test sample. 
  6. Sample support suited to hard or smooth samples. 
  7. Shortest gas route to fast indicate test results. 
  8. DAQ System designed to display all test results to exactly match with each standard (It can be make stronger measuring and more correct & fine test result and also more powerful repeatable performance). 
  9. Foot switch controller to easily control the DAQ System. 
  10. Simple and compact design. 
  11. Portable ignition fixture with precise needle valve control the ignition flame height easily.
  12. The oxygen concentration measurement range: 0 to 100%.

Specification:
Product nameISO 4589-2 ASTM D2863 Fabric Vertical Flame Spread Tester
Size435mm(W)*550mm(D)*670mm(H)
Power220V, 60 Hz, 1A
Weightabout 30 kg
ManualSupplied