UV Aging Test Chamber

China UV Aging Test Chamber, Find details about China UV Aging Test Chamber from UV Aging Test Chamber

Model NO.
QX-5669
Model NO.
QX-5669
UV aging test chamber
Range of application
(1) QUV is the most widely used weather test machine in the world
(2) it has become the world standard for accelerated weathering tests in the laboratory: in accordance with ISO, ASTM, DIN, JIS, SAE, BS, ANSI, GM, u.s.govt and other standards and national standards.
(3) fast and true reproduction of material damage caused by sunlight, rain and dew: in only a few days or weeks, QUV can reproduce the damage that takes months or years to produce outdoors, including fading, discoloration, decreased brightness, pulverization, cracking, blurry, embrittlement, decreased strength and oxidation.
(4)QUV's reliable aging test data can accurately predict the weatherability (anti-aging) of the product, and help to select and optimize the material and formula.
(5) a wide range of applications, such as: paint ink paint, resin, plastic, printing and packaging, adhesives, automotive
Motorcycle industry, cosmetics, metal, electronics, electroplating, medicine, etc.
International test standards :ASTM D4329, D499, D4587, D5208, G154, G53;ISO 4892-3, ISO 11507;EN 534.PrEN 1062-4, GB/T2423.24;BS 2782;JIS D0205;SAE J2020 D4587 and other current uv aging test standards.
II. Structural material system
1. Test chamber space: 1100×700×300mm
2. Overall size: 1450×880×1700mm
3. Material of the unit: 304 stainless steel inside and outside
4. Sample frame: aluminum alloy frame type base frame view plate
5. Controller: TIMI880 (full touch screen programmable controller)
6, power leakage circuit breaker control circuit overload short circuit alarm, alarm over temperature, water protection
. Technical parameters
1. Operation requirements: radiation, spraying and condensation loop operation can be carried out;
2. Built-in water tank
3. Temperature and temperature can be displayed.
4. Temperature range :RT+10ºC~70ºC;
5. Light temperature range :RT+10ºC~70ºC/ temperature tolerance is ±2ºC
6. Temperature fluctuation :±0.5ºC;
7. Humidity range: ≥90%RH
8..Humidity fluctuation :±2%;
9..Lamp center distance :70 mm;
10..Sample and lamp center distance :50 mm;
11..Tank depth requirements :25 mm, automatic control;
12. Effective irradiation region :1100*710*400 mm;
13. Radiation intensity: adjustable within 2.0w /m2/340nm;
14. Ultraviolet wavelength: the wavelength range of uv-b is 280-315nm;
15. Measuring range of blackboard thermometer :20ºC~90ºC/ temperature tolerance is ±1ºC;
16. Uv light and condensation time can be alternately adjusted;
17. Blackboard temperature :40ºC~65ºC;
18. Lamp tube: L= 1200/40w, 8 (the service life of UVA imported Atlas lamp tube is more than 1600h)
19. Controller: TIMI880 (full name: touch screen controller;Programmable light, rain, dew;Temperature setting range and time)
20. Temperature control: operate before the controller interface
22. Water depth of the tank: 25mm automatic control
23. Ultraviolet wavelength: the range is 200-400nm
24. Test time: 0~999H (adjustable)
25. The unit has the function of automatic spraying
.Structure description
1. The box is made of CNC equipment, with advanced technology, smooth lines and beautiful appearance
2. The box is made of 304SUS advanced stainless steel with a thickness of 1.0mm
3. The air duct in the box adopts single circulation system and has an imported axial flow fan, which improves the flow brightness and heating capacity of the air and greatly improves the temperature uniformity in the test box
4, water and consumption: tap water or distilled water about 8 liters/day
5. The heating method is tank heating, with fast heating and even temperature distribution
6, the door for one-way stretching, closed easily
7. The water level of the tank can be replenished automatically to prevent the damage of the heating tube
8. The sample holder is made of stainless steel or aluminum alloy
9. The bottom of the unit is fixed with high-quality PU movable wheel
10. Drainage system USES U - type sedimentation device for drainage
11. The sample surface is parallel to the ultraviolet lamp plane
12. The spray system is equipped with automatic sprinkler head and adjustable water pressure
V. Safety protection device
1. Ground protection
2. Power overload short circuit breaker
3, control circuit overload, short circuit fuse
4. Water shortage protection
5. Over temperature protection
.Temperature control
UV:
First-order optical reactions are not sensitive to temperature changes, whereas the speed of subsequent second-order reactions is closely related to temperature changes.Generally speaking, the reaction speed will be accelerated as the temperature increases. Therefore, it is important to control the temperature during the UV exposure test.The temperature of UV process in the equipment is set to any point between 50ºC and 70ºC, depending on the level of illumination and indoor ambient temperature.The temperature adjustment of the equipment is accomplished by a series of systems such as air heater, water heater and so on, which are directed by a controller with microcomputer calculation function.
. Moisture:
As the temperature increases, the destructive power of moisture on materials increases dramatically.Therefore, temperature control is the most basic requirement in wet process.Furthermore, to produce an acceleration effect, it is necessary to maintain a high temperature environment during the wet process.So the temperature of the condensation process is set to any point between 40ºC and 60ºC.
Heating system
1. High speed heating electric heat pipe of u-shaped titanium alloy is adopted
2. Completely independent system of temperature control and illumination
3. The temperature control output power is calculated by microcomputer to achieve high precision and high efficiency
4. The heating system has anti-overtemperature function:
1) the blackboard temperature is controlled by a color touch screen program controller or a digital key temperature controller. The output power is calculated by microcomputer. The PID self-tuning is adopted.
2) the temperature of the water tank is controlled by the color touch screen program Korean temperature controller.In the test process, one of the test sections is the dark condensation process, which requires the box body to produce high temperature saturated water vapor, when the water vapor encounters the relatively cold sample surface, it will condense dew on the sample surface.
Viii. Operating conditions of the equipment
1. Ambient temperature: 5ºC~+32ºC;
2. Environmental humidity: ≤85%;
3. Power requirements: AC220 (±10%) V/50HZ
4. Pre-installed capacity: 3KW

Ix. Configuration list
 serial numberName of the accessoriesBrandplace of originNumber Note information
1Stainless steel1.0mmdomestic1Carton material
2Stainless steel1.0mmdomestic1After the CNC folding bay
3UV lampAtlasThe United States8Inner box material;By CNC folding bay;Good temperature resistance
5Transmission motorwanxinTaiwan140 w
6Speed regulation valvexinsanliTaiwan1Stepless adjustable
7Control instrumentTIMI880South Korea1Touch screen
8voltmeterpointerdomestic1 
9switchMing weftTaiwan1 
10castor Brake typedomestic4 
11Siemens PLC template6ES7231-7PB22-OXA8Germany2 
12Ac contactor20Achint2 
13Heating electric heat pipeUL100Taiwan2 
14Temperature sensorPT100Shanghai3 
15The blackboardElectrophoretic treatment of aluminum alloyspecial1 
16Thermal protectorN6234Taiwan1 
17Water jet circulating pumpS-6512/220VShanghai xishan pump1 