FeaturesNo need the power supply when it works.
Bipolar excitation working mode, the sensor outputs a pair of positive and negative electrical pulse signal when the magnetic field polarity changes for a circle.
Only when the external magnetic field polarity changes, magnetic strength reaches the excitation threshold, the sensor will outputs a pulse signal, so the vibration won't happen. The operation is stable and reliable.
The signal amplitude has nothing to do with the magnetic field changing speed, and it can work at the speed near to zero.
The signal processing is simple, and it can be directly connected with transistors, comparators, A/D converter, etc.
The output signal can be remote transmitted by the signal lines, it's suitable for LAN management.
No mechanic contact, no spark, is a kind of intrinsic safety devices.
Wide operating temperature range, strong environmental adaptability.
Performance IndexName | Symbol | Value | Unit |
Excitation strength | Min. | B | 2.5 | mT |
Typ. | 7~8 |
Max. | 12 |
Pulse signal amplitude | Vo | ≥1.5 | V |
Pulse width(in the location of 1V) | τ | 10~30 | μS |
DC internal resistance | Ro | 800~1200 | Ω |
Operating frequency | Min. | f | unlimited | kHz |
Max. | 10 |
Operating Temp. | T | -20~+85 | ºC |
Outline Dimension and Typical installation location | - | See the figure | - |
Sensitive silk location(distance to the bottom surface of sensor) | D | Central axis | mm |
Package | - | Aluminum shell, Epoxy potting | - |
External lead | - | Tinned copper hard leads | - |
Sensor dimension and sensitive silk locationInstruction Example: The inlet of the heater is in application.(See the following left figure)
Note: The sensor has certain requirements to the magnetic strength, too strong or too weak magnetic field may affect its operation.(See the excitation strength on "Performance index" )
The working mode is shown as the following right figure.(if using other shape magnet, the installation distance should be adjusted.)