China Ring Main Unit Switchgears, Rmu, RM6, Switchboard, Find details about China RM6 from Ring Main Unit Switchgears, Rmu, RM6, Switchboard
Standards
IEC 62271-100 high voltage alternating current circuit breakers
IEC 62271-105: alternating current switch-fuse Combination
IEC 62271-102: alternating current disconnectors and earthing switches
IEC 62271-200 A.C. metal enclosed switchgear and controlgear for rated voltage above 1 kV and up to and including 52 kV
IEC 62271-103 high voltage switches for rated voltage above 1 kV and less than 52 kV
IEC 60694: Common specifications for high-voltage switchgear and controlgear standards
IEC 60265-1 Switches for rated voltages above 1 kV and less than 52 kV
IEC 60529: Degrees of protection provided by enclosures (IP Code)
Service environment:
a) Air temperature:Maximum temperature: +40ºC; Minimum temperature:-25ºC
b) Humidity:Monthly average humidity 95%; Daily average humidity 90% .
c) Altitude above sea level:Maximum installation altitude: 3000m
d) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.
e) No frequent violent shake
Technical data
Item | Unit | Switch | Switch-fuse | Vacuum circuit-breaker |
Rated voltage | kV | 24 | 24 | 24 |
Power frequency withstand voltage | kV | 50 | 50 | 50 |
Impulse withstand voltage | kV | 125 | 125 | 125 |
Rated current | A | 630 | 2001) | 200 |
Breaking capacities: |
|
|
|
|
active load | A | 630 |
|
|
closed loop | A | 670 |
|
|
off load cable charging | A | 141 |
|
|
off load transformer | A |
| 20 |
|
earth fault | A | 160 |
|
|
earth fault cable charging | A | 91 |
|
|
short-circuit breaking current | kA |
| see 2) | 16 |
Making capacity | kA | 40 | see 2) | 40 |
Short time current 0,5 sec | kA |
|
| 16 |
Short time current 1 sec | kA |
|
| 16 |
Short time current 3 sec | kA | 16 |
|
|
1) Depending on the current rating of the fuse-link 2) Limited by high voltage fuse-links
GRM gas insulated ring main unit is for the secondary distribution network 11/17.5/24/36 kV. It is a completely sealed system with a stainless steel tank containing all live parts and switching functions. A sealed steel tank with constant atmospheric conditions ensures a high level of reliability as well as personnel safety and a virtually maintenance-free system.
It offers a choice of either switch-fuse combination or circuit-breaker with relay for protection of the transformer. SafeRing can be supplied with an integrated remote control and monitoring unit
Switch Module:
The switch Module is a three position switchdisconnector and earthing switch using SF6 gas as an arc quenching medium.
The switch position is close - open - earthed. In the open position the switch satisfies the disconnector requirements.
F Module:
The switch-fuse module has a three position switch disconnector and earthing switch identical to the switch module.
By means of the fuse tripping device it operates as a switchfuse combination. There is a double earthing switch which in earthed position connects earth to both sides of the fuse-links simultaneously.
Both earthing switches are operated in one operation. The switch-fuse and earthing switch is mechanically interlocked to prevent hazardous access to the fuse-links.
The lower cover which gives access to the fuse-links is also mechanically interlocked with the earthing switch.
V Module:
The vacuum circuit-breaker module has vacuum bottles as interrupters of the current.
In series with the circuit-breaker main circuit is connected a three-position disconnector / earthing switch.
The operation between vacuum circuit-breaker and disconnector/ earthing switch is mechanically interlocked.