1A 5A 10V Toroidal CT Split Core Current Sensor Transformer

China 1A 5A 10V Toroidal CT Split Core Current Sensor Transformer, Find details about China 1A 5A 10V Split Core Current Sensor, Toroidal Split Core Current Transformer from 1A 5A 10V Toroidal CT Split Core Current Sensor Transformer

Model NO.
GWSCCT667B
Insulating Medium
Epoxy Resin
Installation
Active Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Frequency
50-400Hz
Rated Input
5A-3000A
Measuring Range
5%in-130%in
Rated Output
0-10V(AC) or 0-5A
Dielectric Strength
3.0kv/1mA/1min
Insulation Resistance
DC500V/100mohm Min
Case
ABS /UL94-V0
Construction
Tie
Output Connection
Terminal
Bobbin
PBT
Trademark
Grewin
Transport Package
Carton or Pallet
Specification
CE, ROHS
Origin
China
HS Code
85045000
Model NO.
GWSCCT667B
Insulating Medium
Epoxy Resin
Installation
Active Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Frequency
50-400Hz
Rated Input
5A-3000A
Measuring Range
5%in-130%in
Rated Output
0-10V(AC) or 0-5A
Dielectric Strength
3.0kv/1mA/1min
Insulation Resistance
DC500V/100mohm Min
Case
ABS /UL94-V0
Construction
Tie
Output Connection
Terminal
Bobbin
PBT
Trademark
Grewin
Transport Package
Carton or Pallet
Specification
CE, ROHS
Origin
China
HS Code
85045000

Product Description

1.Product pictures

1A 5A 10V Toroidal CT Split Core Current Sensor Transformer
1A 5A 10V Toroidal CT Split Core Current Sensor Transformer

2.Features:
Epoxy Potting, Double-screw fastening, safe, easy to install, portable
Wide inner window, allowing clamping of big cables or bus-bars
Wide range of sizes to accommodate all the existing installations

3.Applications:
Current measurement, monitoring and protection for electrical wiring and equipment.
Current and power measurement for electric motors, lighting, air compressor, heating and ventilation system, air-condition equipment and automation - control system.
Current, power and energy monitoring device.Relay protection device.

4.Electrical Parameter:
 
Frequency50-2.5KHz
Rated Input5A-3000A
Measuring range5%In-130%In
Rated Output0-10V(AC) or 0-5A
Ratio≤± 0.1%
Phase angle≤ ±5min
Dielectric strength3.0KV/1mA/1min
Insulation ResistanceDC500V/100Mohm min

5.Mechanical Parameter:
 
CaseABS/UL94-V0
BobbinPBT
CoreSilicon steel
Internal structureEpoxy
ConstructionTie
Operating Temp-25ºC~+75ºC
Operating Humidity≤85%
Output ConnectionTerminal

6.Circuit connection diagram:
1A 5A 10V Toroidal CT Split Core Current Sensor Transformer
7.Size
1A 5A 10V Toroidal CT Split Core Current Sensor Transformer

8.Details of the data


1A 5A 10V Toroidal CT Split Core Current Sensor Transformer

1A 5A 10V Toroidal CT Split Core Current Sensor Transformer
Company introduction


1.certification

We have passed ISO9001:2015,CE,SGS approval and IEC report
Low Loss Electrical Power Voltage Transformer with ISO9001: 2015
Low Loss Electrical Power Voltage Transformer with ISO9001: 2015


2.Company profile
     Tianjin Grewin is concentrating on transformers for 20 Years and complianted by ISO9001:2015,CB,IEC CB,CE etc.We're always pay great attention to its business philosophy "Quality and Honesty First".GWSCTC660A series retro-fit (split-core) current transformer has been specially designed to facilitate their installation in new or already existing net works. They may be installed without opening any cable or bus-bar circuit. An internal precision resistor across the secondary winding of the CT provides a low safe voltage output. It can save time and the installation costs.windely used in communications,electronics,meters,industrial control,medical equipments and other fields.We are also a provider of power meters and instruments locators. 85% of its products exported to America, Europe, and Asia etc.We sincerely invite you to join us to create a bright future.

Low Loss Electrical Power Voltage Transformer with ISO9001: 2015

3.Terms of Shipment:

Within 10 working days after received related prepayment or L/C.

4.Payment terms:
(1)T/T 100% or 50% deposit by T/T in advance, balance amount to be paid 7 days before
delivery.
(2) By irrevocable L/C at sight, to be issued immediately against confirmed order.
(3)Payment by T/T, if order amount is less than USD 20,000.

5.Production
The following picture showed you about all finished transformer production line and package with export standard carton and strong pallets:
1A 5A 10V Toroidal CT Split Core Current Sensor Transformer

6.Warranty:
(1)We provide 1 year warranty.
(2)If the product is defective, please notify us within 3 days of delivery.
(3)All products must be returned on their original condition, in order to qualify for a refund or exchange of goods

7.Why choose us?

Quality and honest first!
A. Flexible service for diffierent transformers with high efficiency performance.
B. Over 40 years experience of transformer designing and producing.
C.100% test of every single product we produce from incoming material checking.
D. UL, CE, ISO9001:2008
E. We offer custom-made transformers, OEM and ODM are welcome
F. We deliver the quality you expect at consistently competitive prices
G.Transformer quality lifetime:10 Years.
H.Specialty Sales service:5 -10 Years

8.Flow chart of trading activities:


NO

Step

Days need

1

Request for quotation

1 day

2

Making quotations

1 day

3

Offer and counter offer

3 days

4

Sending and receiving samples

3-10 days

5

Sample confirmation

3 days

6

Placing a firm order

1 day

7

Paying and receiving the down payment

1-4 day

8

Factory production & Quality inspection

15-20 days

9

Paying and receiving the balance

4 days

10

Delivery of goods

1 days

9.contact