China Bh-108UC M8 Cylinder Metal Electrical Inductance Proximity Sensor Switch, Find details about China Proximity Sensor, Proximity Switch from Bh-108UC M8 Cylinder Metal Electrical Inductance Proximity Sensor Switch
Model | BH-118UC | |||
Type | DC , Non-shielded | |||
Shape | M18 | |||
Detecting distance | 15 mm ±10% | |||
Detectable object | Ferrous metals (see Characteristics for nonferrous metals) | |||
Standard target | 50 x 50 mm | |||
(iron, t=1 mm ) | ||||
Hysteresis | 20% max. of detecting distance, within -10 to +70°C | |||
Response frequency | 350 Hz | |||
Operation mode | N.C. | |||
Temperature characteristics | ±10% max. of detecting distance, | |||
within -10 to +70°C | ||||
Control output | 5 to 200 mA | |||
(switching capacity) | ||||
Protection circuit | Reversed polarity, short-circuit, surge voltage | |||
Rating | Power voltage | 12 to 24 VDC, Ripple (P-P) 20 % or less | ||
Current consumption (leakage | Current consumption (leakage current): 1.0 mA max., Residual voltage: 3.6 V max. (with 2-m cable) | |||
current) | ||||
Residual voltage | Residual voltage: 3.6 V max. (with 2-m cable) | |||
Environmental resistance | Enclosure rating | IP67 | ||
Ambient temperature | -25 to +80 °C (No freezing) | |||
Relative humidity | 35 to 95 % RH (No condensation) | |||
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm , 2 hours in each of the X, Y, and Z directions | |||
Shock resistance | 1,000 m/s2, 3 times in each of the X, Y, and Z directions | |||
Case material | Nickel-plated brass | |||
Accessories | Nut × 2, toothed washer × 1, instruction manual | |||
Weight | About 140 g |