High Model Medical Ventilator Equipment Ventilator Unit

China High Model Medical Ventilator Equipment Ventilator Unit, Find details about China Ventilator, Medical Ventilator from High Model Medical Ventilator Equipment Ventilator Unit

Model NO.
PA-700B
Anesthesia
Pneumatically Driven & Electronically Controlled,
Type of Operating Light
Double Operating Light
Display
10.4 Inch High Visibility Color TFT Display
Ventilation Mode
A/C, Ippv, Sippv, Imv, Simv, Standby, Spont Manual
Minute Volume
Greater Than or Equal to 18L
Tidal Volume
Adjustable Range: 50-1500ml, Display Range: 0-2000
Respiratory Rate
1-99bpm
I:E
4:1-1:4
Peep
0-10CMH2o
Simv Rate
1-20bpm
Adjustable Oxygen Concentration
21-100%
OEM
Yes
Trademark
Perlong
Transport Package
Standard Export Package
Origin
China
HS Code
1111111111
Model NO.
PA-700B
Anesthesia
Pneumatically Driven & Electronically Controlled,
Type of Operating Light
Double Operating Light
Display
10.4 Inch High Visibility Color TFT Display
Ventilation Mode
A/C, Ippv, Sippv, Imv, Simv, Standby, Spont Manual
Minute Volume
Greater Than or Equal to 18L
Tidal Volume
Adjustable Range: 50-1500ml, Display Range: 0-2000
Respiratory Rate
1-99bpm
I:E
4:1-1:4
Peep
0-10CMH2o
Simv Rate
1-20bpm
Adjustable Oxygen Concentration
21-100%
OEM
Yes
Trademark
Perlong
Transport Package
Standard Export Package
Origin
China
HS Code
1111111111
PA-700B Medical Ventilator 


High Model Medical Ventilator Equipment Ventilator Unit


 



Specifications
Model700B (Standard Model)
Display10.4 inch high visibility color TFT display
Ventilation ModeA/C, IPPV, SIPPV, IMV, SIMV, Standby, SPONT MANUAL
Minute VolumeGreater than or equal to 18L
Back-up Power SupplyAt least 4 hours
Tidal VolumeAdjustable range: 50-1500ml, Display range: 0-2000ml
Respiratory Rate1-99bpm
Inspiratory/expiratory (I:E) Ratio4:1-1:4
PEEP0-10cmH2O 
SIMV Rate1-20bpm
Inspiratory Pressure Trigger.-10-10cmH2O 
Inspiratory PlateauAdjustable from 0-50% of inspiratory time
Adjustable Oxygen Concentration21-100%
Gas Supply Requirement280~600 kPa medical grade oxygen and compressed air supply
Pressure Limit1.0kPa~6.0kPa
Maximum Safe Operating Pressure≤6.0kPa
Tidal Volume AlarmUpper Limit: 10~2000ml, Lower Limit: 0~1800ml
Airway Pressure AlarmUpper Limit: 0.1~6kPa, Lower Limit: 0~5kPa
Oxygen Concentration AlarmUpper Limit: 22~100%, Lower Limit: 21~80%

 

About us,

Perlong Medical Equipment Co.,Ltd., Seeuco Electronics Technology Co.,Ltd., was founded in Nanjing, China with the goal to supply products with high quality, competitive price and good after-sell service.




High Model Medical Ventilator Equipment Ventilator Unit