630mA High Frequency Radiography System

China 630mA High Frequency Radiography System, Find details about China X-Ray Machine, X Ray Machine from 630mA High Frequency Radiography System

Model NO.
XM-HF50-R
Lowest Current Time
0.5 Mas
Rated Focal Spot Value
0.6
Table Surface Lock Mode
Electromagnetic Lock
Grid Dimension
356mm × 432mm ( 14"× 17")
Filter Vibrating Mode
Fixed
Trademark
Perlong
Specification
ISO
Origin
Jiangsu, China
Model NO.
XM-HF50-R
Lowest Current Time
0.5 Mas
Rated Focal Spot Value
0.6
Table Surface Lock Mode
Electromagnetic Lock
Grid Dimension
356mm × 432mm ( 14"× 17")
Filter Vibrating Mode
Fixed
Trademark
Perlong
Specification
ISO
Origin
Jiangsu, China
630mA High Frequency Radiography System

Generator:
Kvp Range:
Radiography 40 ~ 150KVp
MA Range: Radiography 25 ~ 630mA
Time Range:
Radiography :1.0 ms ~ 5000ms
Lowest Current Time: 0.5 mAs
3-Phase Power Supply: 380VAC± 38VAC
Power Frequency: 50Hz± 1Hz / 60Hz± 1Hz
Power Capacity: 60KVA

X-ray Tube:
Rated Voltage: 150kV
Rated Focal Spot Value: 0.6
Anode Heat Storage Capacity: 2, 30, 000HU
Heat Storage of Tube Assembly: 1, 350, 000HU

Radiographic Table:
Table Surface (L× W× H): 2100× 800× 650 mm
Table Surface Moving Range:
Vertical: 900mm;
Horizontal: 240mm
Table Surface Lock Mode: Electromagnetic lock, braking force≥ 100N
Table Surface Lock Control: Foot switch (permanent on status)
Grid Dimension: 356mm × 432mm ( 14"× 17")
Filter Vibrating Mode: Fixed

Dimension of The Film used in Filter:
Max. 356mm × 432mm (14"× 17") (17" film can only be used in table vertical direction
Source Assembly StandX-Ray Tube components Up-and-Down Motion Range≥ 1220mm
Movement Range Between Tube Focus and Film1100mm
X-Ray Tube Assembly Vertical Motion Range≥ 2380mm
X-Ray Radiation Component Rotating Range Around Support Arm Axis-120° ~ +120°
X-Ray Radiation Component Rotating Range Around the Vertical Axis of the Stand0° ~ ± 90° And 90° Mechanical positioning lock
X-Ray Tube Assembly Locking ForceElectromagnetic locking braking force ≥ 100N

Collimator Mode of Adjustment Manuel
Radiation Field:450× 450mm [Max SID = 100cm]; 2× 2mm [Min SID = 100cm]
Time Limit of the Light Source: ≤ 30s
Ion Chamber:Sensitivity Per Measuring Field60-80 pC/uGy
Difference Of The Measuring Field≤ 5%
Dose Rate Range: 0.5-1000 uGy/s
Exposure Dose Range: 1ms-10s
630mA High Frequency Radiography System
Generator Kvp Range Radiography 40 ~ 150KVp
mA Range Radiography 25 ~ 630mA
Time Range Radiography 1.0 ms ~ 5000ms
Lowest Current Time 0.5 mAs
3-Phase Power Supply 380VAC±38VAC
Power Frequency 50Hz±1Hz / 60Hz±1Hz
Power Capacity 60KVA
X-ray Tube Rated Voltage 150kV
Rated Focal Spot Value 0.6
Anode Heat Storage Capacity 2,30,000HU
Heat Storage of Tube Assembly 1,350,000HU
Radiographic Table Table Surface (L×W×H) 2100×800×650 mm
Table Surface Moving Range Vertical: 900mm; Horizontal: 240mm
Table Surface Lock Mode electromagnetic lock, braking force≥100N
Table Surface Lock Control foot switch (permanent on status)
Grid Dimension 356mm × 432mm ( 14"×17")
Filter Vibrating Mode fixed
Dimension of The Film used in Filter Max. 356mm × 432mm (14"×17") (17" film can only be used in table vertical direction
Source Assembly Stand X-Ray Tube components Up-and-Down Motion Range ≥1220mm
Movement Range Between Tube Focus and Film 1100mm
X-Ray Tube Assembly Vertical Motion Range ≥2380mm
X-Ray Radiation Component Rotating Range Around Support Arm Axis -120° ~ +120°
X-Ray Radiation Component Rotating Range Around the Vertical Axis of the Stand 0° ~ ±90° and 90° mechanical positioning lock
X-Ray Tube Assembly Locking Force Electromagnetic locking braking force ≥ 100N
Collimator Mode of Adjustment Manuel
Radiation Field 450×450mm [Max SID = 100cm]; 2×2mm [Min SID = 100cm]
Time Limit of the Light Source ≤30s
Ion Chamber Sensitivity Per Measuring Field 60-80 pC/uGy
Difference Of The Measuring Field ≤5%
Dose Rate Range 0.5-1000 uGy/s
Exposure Dose Range 1ms-10s