China VFD Inverter Speed Control with 220V 2.2kw for Spindle Motor, Find details about China Power Inverter, Power Inverters from VFD Inverter Speed Control with 220V 2.2kw for Spindle Motor
Personalized feature | |
Frequency range | 0~1000.00Hz |
Power rang | 220V Grade/1.5~15KW 380V Grade/1.5~15KW |
Carrier frequency | 1KHz~15 KHz; |
Input frequency | 0.01HZ |
Control technology | V/F |
Speed adjustable range | 1:100(SVC) |
Precision of stable speed | ±0.5%(SVC) |
Torque control precision | ±5%(VC) |
Torque lifting | Automatic torque lifting; Manual torque lifting 0.1%~30.0% |
V/F curve | 3 ways to set in the range of 5-1000Hz of rated frequency: linear type, Multipoint type,N th type V/F curve(1.2 power,1.4power,1.6power,1.8 power ,2 power) |
acceleration and deceleration curve | acceleration and deceleration mode: straight line/ S curve 3 kinds of acceleration and deceleration time The range of acceleration and deceleration time:0.0~6500.0s |
DC braking | DC braking frequency:0.00Hz~ Max output frequency Baking Time:0.0s~50.0s Baking current value:0.0%~150.0% |
AVR | When the voltage of the network changes, the output voltage can be kept constant automatically. |
Torque limitation and control | Excavator characteristics, Automatic torque limitation during operation, Prevention of frequent overcurrent tripping |
Safety Self-inspection of Power supply Peripheral equipment | Accomplish power on the Peripheral equipment for Safety Detection such as grounded short circuit etc |
Common DC bus function | Realizing the function of DC bus shared by several Inverters |
Display and keyboard | |
LED display | Display monitoring parameters sush as: output frequency, Setting frequency, bus voltages etc |
Protect function | Short-circuit detection of electrified motor |
Operation | |
Run command channel | Three channel: 1.operation panel given 2.control terminal given 3.Serial port given Can be switched in a number of ways |
Frequency instruction | 8 kinds of Frequency instruction:1. Number given 2. analog voltage given 3. Analog current given 4. serial port given etc. Can be switched in a number of ways |
Input terminal | Six digital input terminals, Compatible with active PNP or NPN input modes; Two analog input terminals can be used as input voltage or current |
Output terminal | An open-circuit collector output terminal, Two relay output terminals; Two analog output terminal: 0/4mA~20mA or 0/2V~10V The output of physical quantities such as setting frequency, output frequency and so on can be realized. |
CL300 series | |||||
Model No. | Dimension of case | Rated power (KW) | Rated current (A) | Adaptive motor ((KW) | input voltage |
CL300-2T1.5-DK | E22(118*185*150) | 1.5 | 6.6/7.0 | 1.5 | Triple phase 220V |
CL300-2T2.2-DK | 2.2 | 8.8/9.6 | 2.2 | ||
CL300-2T4.5-DK | E75(160*247*186) | 4.5 | 20 | 4.5 | |
CL300-2T5.5-DK | 5.5 | 25 | 5.5 | ||
CL300-2T7.5-DK | 7.5 | 32 | 7.5 | ||
CL300-2T9.0-DK | E015(205*322*209) | 9 | 39 | 9.0 | |
CL300-2T11-DK | 11 | 45 | 11 | ||
CL300-4T1.5-DK | E22(118*185*150) | 1.5 | 3.8 | 1.5 | Triple phase 380V |
CL300-4T2.2-DK | 2.2 | 5.1 | 2.2 | ||
CL300-4T4.0-DK | 4 | 9 | 4 | ||
CL300-4T5.5-DK | E75(160*247*186) | 5.5 | 13 | 5.5 | |
CL300-4T7.5-DK | 7.5 | 17 | 7.5 | ||
CL300-4T9.0-DK | 9 | 20 | 9 | ||
CL300-4T11-DKA | 11 | 25 | 11 | ||
CL300-4T11-DK | E011(210*336*200) | 11 | 25 | 11 | |
CL300-4T15-DK | 15 | 32 | 15 | ||
frequency range: 0-1000Hz |
Operating panel instruction | ||
KEY | NAME | FUNCTION |
PRG/ESC | Programming key | entry/return to previous menu |
ENTER/DATA | Confirmation key | Step by step into the menu, confirm Setting parameter |
+ | Incremental key | Increment of data or function code |
- | Decremental key | Decrement of data or functional codes |
SHIFT | Shift key | The display parameters can be cyclically selected under the running and downtime display interface: can select the modification bit of the parameter when modify a parameter |
RUN | Running key | For running operations |
STOP/RES | Stop/Reset | press this key to stop the operation when the machine is working and reset operation in fault alarm state |
M | Mul selection Key | Multifunctional switching selection |
Case | Dimension(mm) | Shell body | |||||
A | B | H | W | D | d | plastic shell body case | |
E22 | 118 | 172.5 | 185 | 105.5 | 150 | 5 | |
E75 | 160 | 235 | 247 | 148 | 186 | 5.5 | |
E015 | 210 | 322 | 336 | 150 | 200 | 7 | mental shell body case (wall - mounted) |
E011 | 210 | 322 | 336 | 150 | 200 | 7 | |
E018 | 290 | 429 | 455 | 274 | 230 | 6 |