China Veterinary Hospital Healthy Center Pet Anesthesia Ventilator Me05 for Animal Using, Find details about China Veterinary, Medical Equipment from Veterinary Hospital Healthy Center Pet Anesthesia Ventilator Me05 for Animal Using
Hot sale Veterinary Anesthesia Ventilator with Color Touch Screen ME03 Pet Ventilator
Veterinary Anesthesia Ventilator Product Feature:
Basic description | ||
Parameter | Description | |
Display | 8 " TFT, with touch screen. | |
Drive gas | Gas type | O2 or Air |
Inlet pressure | 280-600 kPa. | |
Max flow | ≤ 120 L / min. | |
Operating Mode | VCV,PCV,SIMV-VC,SIMV-PC,PSV,Manual/SPONT. Optional: SIMV-PRVC, PRVC | |
Waveform | Waveform: Pressure,Flow-rate,Volume,CO2(optional),Pleth(optional) Loop:PV loop, PF loop,FV loop | |
Safety Pressure | System pressure does not exceed 10 KPa. | |
Battery Type | Li-ion,work time more than 3 hours |
monitored parameters | |
Parameter | Description |
Inspiratory tidal volume | Range: 0 ~ 2500 mL; Resolution: 1 mL. Error of ± 20mL or actual value ± 15%, which ever is greater |
Expiratory tidal volume | Range: 0 ~ 2500 mL; Resolution: 1 mL. Error of ± 20mL or actual value ± 15%, which ever is greater |
Minute ventilation | Range: 0 ~ 60 L / min; Resolution: 0.1 L / min. Error of ± 1L/min or actual value ± 15%, which ever is greater |
Spontaneous minute ventilation | Range: 0 ~ 60 L / min; Resolution: 0.1 L / min. Error of ± 1L/min or actual value ± 15%, which ever is greater |
Respiratory rate | Range: 0 ~ 100 bpm; Resolution: 1 bpm. Error of ± 2 beats / min or actual value ± 10%, which ever is greater |
Spontaneous breathing frequency | Range: 0 ~ 100 bpm; Resolution: 1 bpm. Error of ± 2 beats / min or actual value ± 10%, which ever is greater |
Respiratory ratio | Range: 30:1 to 1:150; resolution: 0.1. Error of ± 20%, |
Peak airway pressure | Range: 0 ~ 100 cmH2O; Resolution: 1 cmH2O. Error of ± (2% + 4% of full scale actual reading) |
Mean airway pressure | Range: 0 ~ 100 cmH2O; Resolution: 1 cmH2O. Error of ± (2% + 4% of full scale actual reading) |
PEEP | Range: 0 ~ 100 cmH2O; Resolution: 1 cmH2O. Error of ± (2% + 4% of full scale actual reading) |
Inspiratory plateau pressure | Range: 0 ~ 100 cmH2O; Resolution: 1 cmH2O. Error of ± (2% + 4% of full scale actual reading) |
FiO2(optional) | Range: 15 to 100%; Resolution: 1%. Error is ± (2.5% +2.5% of full scale actual reading) |
Compliance | Range: 0 ~ 300 mL/cmH2O; resolution: 1 mL/cmH2O. Error of ± 20% or ± 5 mL/cmH2O, which ever is greater |
Airway resistance | Range: 0 ~ 600 cmH2O / (L / S); Resolution: 1 cmH2O / (L / S). Error of ± 20% or ± 5 cmH2O, which ever is greater |
EtCO2 (optional) | Range: 0 ~ 100 mmHg; Resolution: 1 mmHg. Error is ± (0.43% of the volume percentage + 8% of the gas concentration) is equivalent to the range of optional units to monitor KPa and mmHg. |
Inhalation of carbon dioxide (optional) | Range: 0 ~ 100mmHg; Resolution: 1 mmHg. Error is ± (0.43% of the volume percentage + 8% of the gas concentration) is equivalent to the range of optional units to monitor KPa and mmHg. |
MAC values(optional) | Range: 0 to 10; resolution: 0.01 |