China 1 Loop 1 Zone Conventional Fire Alarm System Control Panel, Find details about China 1 Zone Control Panel, Fire Alarm Control Panel from 1 Loop 1 Zone Conventional Fire Alarm System Control Panel
Introduction:
The AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detector, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button. The basic unit offers 1 to 8 zones of initiation, up to 16 zones for larger applications.
1. AW-CFP2166 series conventional fire alarm panel is designed based on
EN54 part 2&4 standard.
2. It is modularized design, the panel can expand from 1 zone to 32
zones easily.
3. It has 2 level control mode by a lock.
4. It has 24VDC power supply output.
5. It has FIRE and FAULT signal output.
6. It has 2 general sounders output.
7. Each zone has 1 circuit detectors input.
8. Each zone can be disable by a button.
9. It has RESET button to reset the panel.
10. It has SILENCE button to stop BUZZER and SOUNDERS.
11. It has EVACUATE button to start a manual fire alarm immediately.
12. It has an optional GSM module for fire alarm by SMS.
13. It is economic, user-friendly and easy maintenance.
Mains supply voltage | 110VAC or 220VAC |
Internal power supply | 27.2VDC |
Total output current limited | 500mA @ 240VAC |
Batteries (default configuration) | 12V2.3AH*2 |
Number of circuit | 1 |
End of Line device | 6.8k Ω,5% tolerance, 0.5-1W (colour code-blue,grey,red,gold) |
Call point resistor value | 470 to 680 Ω, 0.5 or 1 watt |
Number of general circuits | 2 |
Outputs fused AT | 600mA |
Maximum number of bells @ 50mA of each Sounder output | 12 |
Battery fuse | 1.85A resettable fuse |
Sounder outputs | 400mA F 20mm |
Output type | NC and NO relay |
Maximum current | 100mA |
Largest acceptable conductor size | 2.5mm2 |
Smallest acceptable conductor size | 0.75mm2 |
Dimensions(mm) | 272X200X70 |
Weight (with batteries) | 5.5kg |
Packaging & Shipping
Packaging Details:
1) PEE bag per unit
2) Outside Cartons
3)Strict & Standard Export Packing Procedures Adopted Exterior Corrugated Hardboard Carton Interior Blister Buffer Staff, Asenware fire pump control equipment.
Related products
Our company
Asenware, manufacturer of fire alarm and fire suppression system since 2005. Our headquarter is in London, UK, with factory Shenzhen, China
We keep our best service for our customers, and have a rich experienced engineer team to design and install for overseas projects.
Product range
1. Addressable fire alarm system(FP100 series,2189,2100 series)
2. Conventional fire alarm system(2166 series)
3. FM200 gas fire suppression system
4. Emergency light system
5. Fire pump system
6. Fire hose and fire hose reel cabinet
Our Services
1.OEM / ODM services.
2.Professional technical team.
3.Offer Free technical support whenever you need
4.Two year warranty and technical maintenance
FAQ
Q1: Are you manufacturer?
A: (yes)
Q2: What is the lead time?
A: usually
Fire control: one week working day
bulk quality: three weeks working days
Emergency lights: two weeks working days
bulk quality: four weeks
FM200: two weeks working day
Fire pump: 25 days
Q3: How do you ship the goods and how long does it take arrive?
A: We usually ship by DHL, UPS, FedEx or by Air. 3-5 days after payment received.
Q4: Can I have a sample order?
A:Yes,we welcome sample order to test and check quality.
Q5: Do you offer OEM service?
A: Yes, we can design the things according to your request.