Gas Booster for Oxygen/Nitrogen/Helium/CO2 Cylinder Filling

China Gas Booster for Oxygen/Nitrogen/Helium/CO2 Cylinder Filling, Find details about China Gas Booster, Gas Booster System from Gas Booster for Oxygen/Nitrogen/Helium/CO2 Cylinder Filling

Model NO.
DGS-DGT40
Boost Medium
Nitrogen/ Argon/Helium/Hydrogen/CO2/Oxygen or Othe
Certificate
Ce
Trademark
SUNCENTER
Transport Package
1 Set/Case by Plywood Case
Origin
China
Model NO.
DGS-DGT40
Boost Medium
Nitrogen/ Argon/Helium/Hydrogen/CO2/Oxygen or Othe
Certificate
Ce
Trademark
SUNCENTER
Transport Package
1 Set/Case by Plywood Case
Origin
China
Gas booster for oxygen/nitrogen/helium/co2 cylinder filling


Gas Booster for Oxygen/Nitrogen/Helium/CO2 Cylinder Filling


Suncenter - Gas booster systems are compact and delicacy solution tailored to customer specific requirements with gas boosters as well as all accessories to be fitted and installed in the frame or a closed cabinet.
To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator.
The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure.
Suncenter - Pneumatic booster system are used for oil free compression of clean shop air as well as industrial gases like Argon, Helium, Oxygen, Hydrogen and Nitrogen,CO2, etc..Driven air from 3 bar to 8 bar (from air compressor).

Operating pressure up to 80 MPa, for higher pressure, pump with double driven heads is an ideal option.


Applications
  1. Pressure test with gas
  2. Gas transfer and filling
(Argon/Helium/Hydrogen/Oxygen/Nitrogen/CO2/NO2/CH4/LNG/LPG/CNG/FM200 etc.)
  1. Charging of gas cylinder and accumulator with nitrogen
  2. Supply for isolating gas systems
  3. Gas assisted injection molding
  4. Transfer of oxygen cylinders
  5. Charging of breathing air bottles
  6. Leak test
  7. Hydrostatic Testing for valves, tanks, pressure vessels, pressure switches, hoses, pipes and tubing, pressure gauges, cylinders, transducers, well casings, BOPs, gas bottles and air craft components
  8. Safety valve adjusting


Suncenter DGS Series Pneumatic (Air driven) Gas Booster Pump System

Gas Booster for Oxygen/Nitrogen/Helium/CO2 Cylinder Filling




DGS booster system = booster pump+ following valves, gages, and parts

Gas Booster for Oxygen/Nitrogen/Helium/CO2 Cylinder Filling


The hottest selling- model A and model C cabinet picture
Gas Booster for Oxygen/Nitrogen/Helium/CO2 Cylinder Filling


The standard gas booster pumps system including following parts:
Air -driven gas booster pump (DGA/DGD/DGT three series for choosing)

Stainless steel (carbon steel) material cabinet (Three models for choosing)

F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

Driven air switch (Pump starting switch), driven air pressure gauge

Gas inlet switch, Gas inlet pressure gauge

Gas outlet switch, Gas outlet pressure gauge,  unloading valve, interconnecting pipes etc.

And we could also customize it according to clients' special requirement.


Technical specification for DGS-DGA series
ModelPressure boost ratioMin. gas
Inlet pressure
PA (bar)
Max.gas
Inlet pressure
PA (bar)
Max. gas
outlet pressure PB (bar)

Driven air pressure  PL
Formula to
calculate gas outlet pressure PB
Connection:
Gas Inlet /
Gas outlet (ZG thread)
Max. flow at driven air pressure of 6bar (L/min)
DGS-DGA022:11.016162-8 bar2X PL1/2 / 1/2960 (at PA of 6 bar )
DGS-DGA055:104040 2-8 bar5XPL1/2 / 1/2680(at PA of 6 bar )
DGS-DGA1010:13.580802-8 bar10XPL3/8/ 3/8210(at PA of 10 bar )
DGS-DGA2525:17.0 200200 2-8 bar25XPL1/4/ 1/4120(at PA of 20 bar )
DGS-DGA4040:1103203202-8 bar40XPL1/4/ 1/4200(at PA of 40 bar )
DGS-DGA6060:120 480480 2-8 bar60XPL1/4/ 1/4180(at PA of 40 bar )
DGS-DGA100100:1258008002-8 bar100XPL1/4/ M14X1.5136(at PA of 40 bar )
DGS-DGA130130:13580010402-8 bar130XPL1/4/ M14X1.5120(at PA of 40 bar )

Note:  PL: driven air pressure   PA: gas inlet pressure   PB: gas outlet pressure 
In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 bar

 

Technical specification for DGS-DGD series

 
ModelPressure boost ratioMin. gas
Inlet pressure
PA (bar)
Max.gas
Inlet pressure
PA (bar)
Max. gas
outlet pressure PB (bar)

Driven air pressure  PL
Formula to
calculate gas outlet pressure PB
Connection:
Gas Inlet /
Gas outlet (ZG thread)
Max. flow at driven air pressure of 6bar (L/min)
DGS-DGD1010:13.58080 2-8 bar10XPL+ PA3/8/3/8410(at PA of 6 bar )
DGS-DGD2525:110 200200 2-8 bar25XPL+ PA1/4/1/4396(at PA of 20 bar )
DGS-DGD4040:115 320320 2-8 bar40XPL+ PA1/4/1/4320(at PA of 40 bar )
DGS-DGD6060:125 480480 2-8 bar60XPL+ PA1/4/1/4215(at PA of 40 bar )
DGS-DGD100100:135 800800 2-8 bar100XPL+ PA1/4/M14*1.5300(at PA of 60 bar )


Note:  PL: driven air pressure   PA: gas inlet pressure   PB: gas outlet pressure 
In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 bar



Technical specification for DGS-DGT series
ModelPressure boost ratioMin. gas
Inlet pressure
PA (bar)
Max.gas
Inlet pressure
PA (bar)
Max. gas
outlet pressure PB (bar)

Driven air pressure  PL
Formula to
calculate gas outlet pressure PB
Connection:
Gas Inlet /
Gas outlet (ZG thread)
Max. flow at driven air pressure of 6bar (L/min)
DGS-DGT2525:10.110200
2-8 bar
25XPL+3.5XPA1/4/ 1/4136(at PA of 8 bar )
DGS-DGT4040:10.110320
2-8 bar
40XPL+ 6XPA
1/4/1/4
124(at PA of 8 bar )
 DGS-DGT10/6010:1/60:10.1104802-8 bar60XPL+6X PA
1/4/1/4
84(at PA of 8 bar )
DGS-DGT25/6025:1/60:11025480
2-8 bar
60XPL+2.5XPA
1/4/1/4
80(at PA of 15 bar )
DGS-DGT100100:10.1108002-8 bar100XPL+10XPA1/4/ M14*1.563(at PA of 8 bar )


Note:  PL: driven air pressure   PA: gas inlet pressure   PB: gas outlet pressure 
In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 bar


How to Select Suncenter Air Driven Gas Boosters/Systems?

In order to choose suitable booster pump or systems for you,
please kindly reply us the following questions:

1.What is your present gas pressure?(    )bar

2.What is your gas?oxygen gas,nitrogen gas or other gases?

3.What outlet gas pressure do you want?(    )bar

4.What driven air pressure (of your air compressor) can you offer?(    )bar,
because our booster is completely air operated and no need any electricity

5.What outlet gas flow rate do you need?(    )L/min

 
 
Gas Booster for Oxygen/Nitrogen/Helium/CO2 Cylinder Filling

 

Dongguan Suncenter Fluid Control Equipment Co., Ltd is the member company of Suncenter Group, which is located in Dongguan city of Guangdong province in China. With more than 15 years experiences in fluid pressure exchange and controlling field, we provide various kinds of pneumatic and hydraulic booster pumps, systems and solutions to the customers all over the world. Due to our best product quality, competitive price as well as excellent after-sales service, we have win a great reputation in the field.
 
Our main products including:
High Pressure Booster Pumps (Air Driven Gas Booster Pump, Air Driven Liquid Pump, Air Amplifiers)
High Pressure Systems (Gas/Liquid Booster Stations,FM200 filling machine, Tube Expanding Machine)
High Pressure Test Equipment(Hydraulic/Burst/Hydrostatic test machine,Cylinder test machine,
Valve test bench,Impulse Testing Machine, etc.)
 
Product Application
Oil Industry, Gas Industry, Chemical Industry, Fire Fighting, Research Institutions etc.
 
Our service
13 months' free warranty since the purchasing date and free technical support during lifetime



Gas Booster for Oxygen/Nitrogen/Helium/CO2 Cylinder Filling