High quality 2 Loops conventional fire panel 1 Zone ![High Quality 2 Loops Conventional Fire Panel 1 Zone](//image.made-in-china.com/226f3j00bueQmkpKfYoJ/High-Quality-2-Loops-Conventional-Fire-Panel-1-Zone.webp)
Introduction:
1 AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.
2 It is modularized design, the panel can expend from 1 zone to 32 zones easily.
3 It has 2 level control mode by a lock
4 It has 24VDC and 5VDC power supply output.
5 It has FIRE and FAULT signal output.
6 It has 2 general sounders output.
7 Each zone has 1 circuit detectors input.
8 Each zone can be disable by a button.
9 It has RESET button to reset the panel.
10 It has SILENCE button to stop BUZZER and SOUNDERS.
11 It has EVACUATE button to start a manual fire alarm immediately.
12 It has battery low protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.
13 It has an optional GSM module for fire alarm by SMS.
14 It is economic, user-friendly and easy maintenance.
Parameters:
ITEM | 1Zone panel | 2Zone panel | 4-8 Zone panel | 12-32 Zone panel |
Model No. | AW-CFP2166-01 | AW-CFP2166-02 | AW-CFP2166-04-8 | AW-CFP2166-12-32 |
Power specification | |
Mains supply voltage | 110VAC or 240VAC |
Internal power supply | 27.2VDC |
Total output current limited | 500mA @ 240VAC | 500mA @ 240VAC | 3A @ 240VAC | 3A @ 240VAC |
Main supply monitor for fault | Yes |
Battery protection for low voltage | Yes |
Batteries (default configuration) | 12V2AH*2 |
Detector circuit specification | |
Number of circuit | 1 | 2 | 4-16 | 4-32 |
Line fault monitor for open circuit | Yes |
Line fault monitor for short circuit | Yes |
Line fault monitor for detector removal | Yes, if End of Line Monitor Unit fitted in place of End of Line Resistor |
End of Line device | 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold) |
Detector continuity diodes | Silicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault) |
Call point resistor value | 470 to 680 Ω, 0.225 or 0.5 watt |
Maximum number of smoke/heat detectors per zone | 20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts. |
Maximum number of manual call points per zone | No limit |
Sounder circuit specification | |
Number of general circuits | 2 |
End of line resistor value | 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold) |
Line fault monitor for open circuit | Yes |
Line fault monitor for short circuit | Yes |
Outputs fused AT | 400mA |
Maximum number of bells @ 20mA of each sounder output | 20 |
Fuses | |
Battery fuse | 1.5A F 20mm |
Sounder outputs | 500mA F 20mm |
Fire and fault output | |
Output type | NC and NO relay |
Maximum current | 100mA |
Connection block | |
Largest acceptable conductor size | 2.5mm2 |
Smallest acceptable conductor size | 0.75mm2 |
Size and weight | | |
Dimensions(mm) | 272*200*70mm | 320*231*90mm | 395X502X124 | 362X565X124 |
Weight (without batteries) | 4kg | 5kg | 7kg | 8kg |
Weight (with batteries) | 5.8kg | 6.8kg | 9.6kg | 12.5kg |
Packaging & ShippingPackaging Details:
1) PEE bag per unit
2) Outside Cartons
3)Strict & Standard Export Packing Procedures Adopted Exterior Corrugated Hardboard Carton Interior Blister Buffer Staff, Asenware fire pump control equipment.
![High Quality 2 Loops Conventional Fire Panel 1 Zone](//image.made-in-china.com/226f3j00opBTdCzgZGbA/High-Quality-2-Loops-Conventional-Fire-Panel-1-Zone.webp)
Related products
Our companyAsenware, manufacturer of fire alarm and fire suppression system since 2005. Our headquarter is in London, UK, with factory Shenzhen, China
We keep our best service for our customers, and have a rich experienced engineer team to design and install for overseas projects.
Product range1. Addressable fire alarm system(FP100 series,2189,2100 series)
2. Conventional fire alarm system(2166 series)
3. FM200 gas fire suppression system
4. Emergency light system
5. Fire pump system
6. Fire hose and fire hose reel cabinet
Our Services1.OEM / ODM services.
2.Professional technical team.
3.Offer Free technical support whenever you need
4.Two year warranty and technical maintenance
FAQ Q1: Are you manufacturer?
A: (yes)
Q2: What is the lead time?
A: usually
Fire control: one week working day
bulk quality: three weeks working days
Emergency lights: two weeks working days
bulk quality: four weeks
FM200: two weeks working day
Fire pump: 25 days
Q3: How do you ship the goods and how long does it take arrive?
A: We usually ship by DHL, UPS, FedEx or by Air. 3-5 days after payment received.
Q4: Can I have a sample order?
A:Yes,we welcome sample order to test and check quality.
Q5: Do you offer OEM service?
A: Yes, we can design the things according to your request.