China 10kVA Constant Current AC Power Source for Components Test, Find details about China Variable Frequency AC Power Supply, Variable Frequency Power Supply from 10kVA Constant Current AC Power Source for Components Test
Model | VFP-S 10KVA | |
Capacity | 10KVA | |
AC Input | Phase | Tri-phase |
Voltage (phase voltage) | 220±22Vac | |
Frequency | 50±2.5Hz | |
Power factor | 0.93 | |
AC Output | Phase | Single-phase |
Max current | 1000A | |
Frequency | 45 ~ 65Hz | |
Voltage | 0~20V | |
Circuit mode | SPWM mode | |
Control mode | Key button | |
Output waveform | Sine wave | |
Frequency Stability | 0.1% | |
Output current distortion | ≤3% (resistive load) | |
Line regulation | 1% | |
Load regulation | 1% | |
Display | VFD | |
Memory function | Automatic memory for working parameters of last operation. | |
On-line setting function | Output current settable during working state. | |
Display resolution | Frequency Meter | Resolution: 0.1Hz, precision: ±0.1% |
Voltage Meter | Resolution: 0.001V, precision: ± (0.3%×reading + 0.2%×rated output) | |
Current Meter | Resolution: 0.01A/0.1A, precision: ±(0.3%×reading + 0.2%×rated output) | |
Power Meter | Resolution: /1W, precision: precision: ±(0.3%×reading + 0.2%×rated output) | |
Time | 0.0 ~ 99.9s, resolution: 0.1s, precision: ±(1%×setting value + 0.1s) | |
Protection functions | Auto tripping and alarm when over load, over temp and short-circuit. | |
Cooling | Forced air cooling | |
Communication port | RS232 (default) RS485 (optional) | |
Analog signal control | Optional as per requirements | |
Environment | Relative humidity | 20% ~ 90% (non-condensing) |
Working temperature | 0ºC ~ 40ºC | |
Height | ≤1500m | |
Size @ Weight | (W*D*H) (mm) | 483*1400*800 @ 240Kg |