West Tune Laboratory Dissolved Oxygen Meter

China West Tune Laboratory Dissolved Oxygen Meter, Find details about China Laboratory Dissolved Oxygen Meter, Dissolved Oxygen Meter from West Tune Laboratory Dissolved Oxygen Meter

Model NO.
Bante980
Range
0.00~20.00mg/L
Accuracy
±0.2mg/L
Resolution
0.01, 0.1mg/L, Selectable
Calibration Points
1 or 2 Points
Temperature Compensation
0~50°c, 32~122°f, Automatic
Pressure Correction
60.0~112.5kpa, 450~850mmhg
Salinity Correction
0~50g/L
Data Hold
Manual or Auto-Endpoint
Stability Criteria
Low or High
Calibration Due Alarm
1 to 31 Days or off
Power off
Manual or Automatic (10, 20, 30 Minutes)
Trademark
West Tune
Transport Package
Standard Export Packing
Origin
China
HS Code
9027809900
Model NO.
Bante980
Range
0.00~20.00mg/L
Accuracy
±0.2mg/L
Resolution
0.01, 0.1mg/L, Selectable
Calibration Points
1 or 2 Points
Temperature Compensation
0~50°c, 32~122°f, Automatic
Pressure Correction
60.0~112.5kpa, 450~850mmhg
Salinity Correction
0~50g/L
Data Hold
Manual or Auto-Endpoint
Stability Criteria
Low or High
Calibration Due Alarm
1 to 31 Days or off
Power off
Manual or Automatic (10, 20, 30 Minutes)
Trademark
West Tune
Transport Package
Standard Export Packing
Origin
China
HS Code
9027809900
Bante980 Laboratory Dissolved Oxygen Meter

MEASUREMENT PARAMETERS
Dissolved oxygen concentration, % saturation of oxygen

FEATURES
* 1 or 2 points calibration using the air-saturated water or zero oxygen solution
* Salinity and barometric pressure compensations provide the reliable measuring results.
* Selectable measurement units, including the mg/L, ppm, mmHg and kPa.
* Automatic Temperature Compensation provides accurate reading over the entire range
* Calibration Due Reminder prompts user to calibrate the meter regularly.
* Stability indicator shows when a measurement is recognized as stable.
* Auto-Hold feature senses and locks the measurement endpoint.
* Setup menu allows setting the 9 parameters, including the number of calibration points,
resolution, stability criteria, etc.
* Reset feature automatically resumes all settings back to factory default options.
* Expanded memory stores and recalls up to 100 data sets.
* Stored readings can be transferred into the computer by USB communication interface
METER INCLUDES
Dissolved oxygen probe, membrane cap, electrolyte solution, electrode holder, power
adapter.


Specification:
ModelBante980
Dissolved Oxygen 
Range0.00~20.00mg/L
Accuracy±0.2mg/L
Resolution0.01, 0.1mg/L, selectable
% Saturation of Oxygen 
Range0.0~200.0%
Accuracy±2.0%
Resolution0.1, 1%
General 
Calibration Points1 or 2 points
Temperature Compensation0~50°C, 32~122°F, Automatic
Pressure Correction60.0~112.5kPa, 450~850mmHg
Salinity Correction0~50g/L
Data HoldManual or Auto-Endpoint
Stability CriteriaLow or High
Calibration Due Alarm1 to 31 days or Off
Power OffManual or Automatic (10, 20, 30 minutes)
Reset FunctionYes
MemoryStores up to 500 data sets
OutputUSB communication interface
Connector6-pin mini plug
DisplayLCD
PowerDC5V, using AC adapter, 220VAC/50Hz
Dimensions210(L)×188(W)×60(H)mm
Weight1.5kg