Cx-Ns-120 Dissolved Oxygen Electrode with High Efficiency

China Cx-Ns-120 Dissolved Oxygen Electrode with High Efficiency, Find details about China Oxygen Electrode, Oxygen Sensor from Cx-Ns-120 Dissolved Oxygen Electrode with High Efficiency

Model NO.
CX-NS-120
Trademark
GN
Transport Package
Carton/Polywood Case /Wood Case
Specification
CE, SGS, ISO
Origin
Shanghai China
HS Code
9027809900
Model NO.
CX-NS-120
Trademark
GN
Transport Package
Carton/Polywood Case /Wood Case
Specification
CE, SGS, ISO
Origin
Shanghai China
HS Code
9027809900
Brief introduction of CX-NS-120 oxygen electrode
NS-120 type oxygen electrode is a diaphragm polarographic (clark) sensor . Byconductibility electrolyte which connect one cathode and one anode to compose .Between the cathode and the anode ,the proper polarization voltage can deoxidize the O2 at the Cathode electrode .
Cathode reaction:O2+ 2H2O +4e → 4OH-
Anode reaction ::4Ag  +4Cl- → 4AgCl + 4e
These chemical reactions produce the current which is proportional to the O2 in the measured solution's
 
CX-NS-120 oxygen electrode
Measuring principlecurrent measurement/polarography
Detection limit<40ppb oxygen percent
Response timethe oxygen content decreased 90%<2min ,when the temperature is 25 C
Residual currentthe residual room temperature signal<2% FS in the anaerobic medium 
Operating temperature0~60C
Pressure0~4bar
Electrode signal20~80nA at 25 Celsius degree (can customize under the requests)
Temperature compensationthermal resistance value can customize it under the user's requests
Electrode sizediameter (12mm) ,length(120mm)(PG13.5 screw thread interface),
can customize under the requests
Electrode material316L stainless steel shell ,POM diaphragm cap
Permeable membraneenganced steel mesh PTFE and polysiloxane film
 
Brief introduction of CX-NS-238 residual chlorine electrode
CXNS-238type residual chlorine is constant voltage sensor . It consist of two platinum electrodes and one micro-battery measurement system . When measuring ,the electrode measured end should keep in a stable electric potential . The different measured content will produce the different and good linearity current intensity under this electric potential .
 
CX-NS-238 residual chlorine electrode
Measurement range0~2ppm,2~20ppm
Electrode2 platinum rings
Reference electrodeGEL with Annular contacts
MaterialGlass
Electrode cable3m high impedance and low noisy shielded cable
Operation pressure10bar at 20C(Max.)
Electrode sizeDiameter 12mm ,length 110mm
 
Brief introduction of CX-NS-70 residual chlorine electrode
1.Sensitive response ,good stability
2.Do not need to replace the diagram and the electrolyte .
3.Suitable for variety of waste water , the diagram is difficult to be damaged, anti-pollution
 
CX-NS-70 residual chlorine electrode
MeasurementHOCl/residual chlorineMinim HOCl/residual chlorine
Range0.05~20ppmHOCl0.01~5ppm
Polarization timeFirst time 30minFirst time 90min
 Second time 10minSecond time 45min
Response time0%<2min(room temperature )
95%<5min(room temperature)
Operating temperature2~45C
Min velocity200~250ml/min,flow-through flow can not less than 30L/h
PH range4~8.2PH
Proof pressure range0~1bar
Temperature compensationThermal resistance value can be customize by the requests
Electrode cable3m high impedance and low noise shielded cable
Electrode sizeDiameter 20mm ,length 70mm
Electrode material316L stainless steel shell ,POM diaPHragm cap ,
PTFE diaPHragm
 
Brief introduction of CX-GP131 High-temperature sterilization pH electrode
1.using new high temperature-sensitive glass membrane
2.the use of high temperature and high temperature solid electrolyte gel electrolyte, ceramic dual-core and Teflon liquid junction structure.
3.pressure is 0.4MP ,Electrode is not reversed in the case of pressure, and can be directly used for temperature 130C sterilization and also can also be effective in the measurement range of 0-95 C.
 
 
CX-GP131 High-temperature sterilization pH electrode
Measuring range0-14pH
Temperature range0-95C
Pressure0.4MP
Sterilization temperature≤130C
JunctionCeramic core
Reference electrodeAg/AgC
Sizediameter 12×120,150,200,250,300mm
 
Brief introduction of CX-ORP-0200 ORP electrode
It is used for the oxidation reduction potential detection in medicine, chlor-alkalichemical, dyes, pulp & paper-making, intermediates, chemical fertilizer, starch,environment protection and electroplating industries.
 
CX-ORP-0200 ORP electrode
MediumWater, acid rain, waste water
temperature range5-70C
measurement body shapeaciculiform platinum
Reference Junctioplastic fibre,single interface, not refillable