Trmf4 250A 3p 200A 250A, Ls Design Following IEC60947-2, MCCB

China Trmf4 250A 3p 200A 250A, Ls Design Following IEC60947-2, MCCB, Find details about China MCCB, Over Load from Trmf4 250A 3p 200A 250A, Ls Design Following IEC60947-2, MCCB

Model NO.
TRMF4
Poles Number
1 Pole, 3poles, 4 Poles
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Overcurrent Protection, Over Load Protection and Short Circuit Protection
Trademark
TRANER
Transport Package
Cartons
Origin
China
HS Code
8536200
Model NO.
TRMF4
Poles Number
1 Pole, 3poles, 4 Poles
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Overcurrent Protection, Over Load Protection and Short Circuit Protection
Trademark
TRANER
Transport Package
Cartons
Origin
China
HS Code
8536200
TRM series MCCB

Standard
TRM series circuit breaker and auxiliaries comply with the following international standard:
1.IEC/EN 60947-1
Low-voltage switchgear and controlgear-part 1: General rules;
2.IEC/EN 60947-2
Low-voltage switchgear and controlgear-part 2: Circuit breakers;

TRM series MCCB(Standard use environment for TRM series MCCB)
1. Ambient temperature: Within the range of -5ºC--+55ºC(However, when the temperature exceed 40ºC,it should be considered to reduce the capacity to use);
2. Relative humidity: Within the range of 45%--85%;
3. Altitude: 2000m or less(However, if it exceeds 1000m, atmosphere correction through humidity test and withstand voltage test can be considered);
4. Atmosphere where excessive steam, oil steam, smoke, dust, salt and other corrosive materials do not exist;

Classification:
According to the poles:                                          1-pole, 3-poles, 4-poles
According to the breaking capacity:                       S-type, H-type
According to the rated current:                               Fix type, Adjustable type(08In-1.0In)
Trmf4 250A 3p 200A 250A, Ls Design Following IEC60947-2, MCCB
Trmf4 250A 3p 200A 250A, Ls Design Following IEC60947-2, MCCB
Technical data table :
Ampere frame sizeTRMF4(250A)
Breaking capacity codeSH
Product code and poles1P3P4P1P3P4P
TRMF4-S1TRMF4-S3TRMF4-S4TRMF4-H1TRMF4-H3TRMF4-H4
Rated current, In(A)100, 125, 160, 180, 200, 225, 250
Adjustable partRated current setting(0.8In-1.0In)χχ
Lockup device for operating handleχχ
Rated operational voltage, Ue(V), AC 50/60 Hz240/415
Rated insulation voltage, Ui(V)1000
Rated impulse withstand voltage, Uimp(kV)8
StandardConformity with IEC/EN 60947-2
Rated frequency(Hz)50/60
Rated short-circuit breaking capacity, Icu(kA)
AC240V25503665
415V-37-50
Ics=% * Icu50%100%50%100%
Mechanical life(circle)7000
Electrical life(circle)1000
Dimension:
Length*Width*Height
1-pole150*38*60
2-poles-
3-poles165*105*60
4-poles130*140*60
Built-in accessory:
Trmf4 250A 3p 200A 250A, Ls Design Following IEC60947-2, MCCB
Built-out accessory:
Trmf4 250A 3p 200A 250A, Ls Design Following IEC60947-2, MCCB

 


Company show:
Trmf4 250A 3p 200A 250A, Ls Design Following IEC60947-2, MCCBTrmf4 250A 3p 200A 250A, Ls Design Following IEC60947-2, MCCBTrmf4 250A 3p 200A 250A, Ls Design Following IEC60947-2, MCCBTrmf4 250A 3p 200A 250A, Ls Design Following IEC60947-2, MCCB
Exhibition:
Trmf4 250A 3p 200A 250A, Ls Design Following IEC60947-2, MCCBTrmf4 250A 3p 200A 250A, Ls Design Following IEC60947-2, MCCBTrmf4 250A 3p 200A 250A, Ls Design Following IEC60947-2, MCCBTrmf4 250A 3p 200A 250A, Ls Design Following IEC60947-2, MCCB