China S-1200-48 Single Output Switching DC Power Supply, Find details about China Switched-Mode Power Supply, DC Power Supply from S-1200-48 Single Output Switching DC Power Supply
Model | SCN-1200-05 | SCN-1200-12 | SCN-1200-15 | SCN-1200-24 | SCN-1200-48 | |
DC output voltage | 5V | 12V | 15V | 24V | 48V | |
Output | Output voltage tolerance | ±2.5% | ±1% | ±1% | ±1% | ±1% |
Rated output current | 180A | 100A | 80A | 50A | 25A | |
Output current range | 0-180A | 0-100A | 0-80A | 0-50A | 0-25A | |
Output power | 900W | 1200W | 1200W | 1200W | 1200W | |
Ripple and the noise | 100mVp-p | 120mVp-p | 150mVp-p | 240mVp-p | 480mVp-p | |
Dc voltage adjustable scope | + 5%; By external 2 ~ 5 V voltage control, which can adjust the output voltage of the rated voltage of the in the range of 40% ~ 100% in value | |||||
Start, rise, keep time | 800ms, 50ms, 16ms Loaded with | |||||
Intput | Input voltage range | 200~260 VAC47~63 Hz; 290~370VDC | ||||
Exchange input current | 11A/230VAC | |||||
efficiency | 85% | 88% | 89% | 91% | 93% | |
Impulse current | 120A230V | |||||
Leakage current | 3.5 mA/240VAC | |||||
Protection characteristics | Overload protection | 101%~115% | 110%~135% | |||
Protection way: current limiting, delay shut off, restart | ||||||
Overvoltage protection | 110%~135% | |||||
Protection way: cut output, restart | ||||||
High temperature protection | TSW1 (power tube) temperature > 100 ºC, restart when cut off output | |||||
Environment | Working temperature, humidity | -10ºC~+65ºC,20%~90 %RH | ||||
Keep temperature, humidity | -20ºC~+85ºC,10%~95 %RH | |||||
Vibrate resistance | 10 ~ 200 Hz ac, 2 G 10 min. / 1 cycle time, 60 minutes, the axis | |||||
Security | Compression sex | I/P-O/P, I/P-FG:1500VAC | ||||
Insulation resistance | I/P-O/P, I/P-FG, >100M Ohms / 500VDC | |||||
Standards | Safety standards | Accord with | ||||
UL1950,CSA22.2,IEC60950 | ||||||
EMC standard | Accord with | |||||
FCC Part 15 Class A | ||||||
Other | Weight | 4.7Kg; | ||||
Packaging | 4pcs/20.2kg/CARTON | |||||
Note | 1. All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ºC conditions measuring income value. | |||||
2. Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement. | ||||||
3. Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate. | ||||||
4. The power to consider as a device installed in final equipment, this equipment must be to make sure it's EMC index. |